Effect of Different Implant-Abutment Connection Materials on the Fracture Resistance of Zirconia Abutments

被引:5
|
作者
AlAmar, Mohammed [1 ]
Alqahtani, Fawaz [2 ]
机构
[1] Minist Hlth, Dept Prosthodont, Riyadh, Saudi Arabia
[2] Prince Sattam Bin Abdulaziz Univ, Coll Dent, Dept Prosthodont, Al Kharj, Saudi Arabia
关键词
abutment; load to fracture; titanium; zirconia; DENTAL IMPLANT; AESTHETIC ZONE; STRENGTH;
D O I
10.1563/aaid-joi-D-19-00192
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of the present in vitro study was to assess the modes of failures under static load among titanium (Ti) and 1- and 2-piece zirconia abutments. The 1- and 2-piece zirconia abutment specimens were fabricated from prescanned Ti abutments. Twenty-one implant abutments and 21 implant replicas were equally divided into 3 groups as follows: (a) Group 1 (Titanium group); (b) Group 2 (1-piece zirconia abutment group); and (c) Group 3: 2-piece zirconia abutment group). A 250 000-cycle linear fatigue load ranging between 10 N and 210 N was applied to all specimens using an all-electric dynamic test instrument. The specimens were loaded until they fractured. In all groups, assessment of mode of fracture was done on visual assessment by a trained and calibrated investigator. Prior sample-size estimation was performed; and sample distribution was assessed using the Kolmogorov and Shapiro tests. Screw fracture (n = 7) and abutment bending at the apical part (n = 7) occurred in the Ti group. In the 1-piece zirconia group, screw and abutment fractures occurred in 7 and 7 cases, respectively. In the 2-piece zirconia screw fracture (n = 7) above the Ti zirconia junction (transgingival segment) and abutment fracture (n = 7) were determined as the failure modes. In vitro, the 1-piece zirconia abutments are more fracture resistant than titanium and 2-piece zirconia abutments. From a clinical perspective, further studies are needed to determine the minimum static load value required to induce fracture of the 1- and 2-piece zirconia abutments.
引用
收藏
页码:88 / 92
页数:5
相关论文
共 50 条
  • [1] The implant-abutment interface of alumina and zirconia abutments
    Yuezueguellue, Bulem
    Avci, Mehmet
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (02) : 113 - 121
  • [2] In Vitro Study of the Influence of the Type of Connection on the Fracture Load of Zirconia Abutments with Internal and External Implant-Abutment Connections
    Sailer, Irena
    Sailer, Thomas
    Stawarczyk, Bogna
    Jung, Ronald Ernst
    Haemmerle, Christoph Hans Franz
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 850 - 858
  • [3] Fracture resistance after implantoplasty in three implant-abutment connection designs
    Camps-Font, Octavi
    Gonzalez-Barnadas, Albert
    Mir-Mari, Javier
    Figueiredo, Rui
    Gay-Escoda, Cosme
    Valmaseda-Castellon, Eduard
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2020, 25 (05): : E691 - E699
  • [4] The implant-abutment connection
    Nelson, Katja
    Zabler, Simon
    Wiest, Wolfram
    Schmelzeisen, Rainer
    Semper-Hogg, Wiebke
    IMPLANTOLOGIE, 2013, 21 (04): : 355 - 363
  • [5] Mechanical behavior of titanium and zirconia abutments at the implant-abutment interface: A systematic review
    Pereira, Anne Karoline de Holanda Cavalcanti
    Limirio, Joao Pedro Justino de Oliveira
    Vasconcelos, Belmiro Cavalcanti do Egito
    Pellizzer, Eduardo Piza
    de Moraes, Sandra Lucia Dantas
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 420 - 426
  • [6] Comparing the Fracture Resistance of Alternatively Engineered Zirconia Abutments with Original Equipment Manufactured Abutments with Different Implant Connection Designs
    Jarman, Joseph M.
    Hamalian, Techkouhie
    Randi, Anthony P.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (05) : 992 - 1000
  • [7] Influence of Implant-Abutment Connection Biomechanics on Biological Response: A Literature Review on Interfaces between Implants and Abutments of Titanium and Zirconia
    Choi, Sunyoung
    Kang, Young Suk
    Yeo, In-Sung Luke
    PROSTHESIS, 2023, 5 (02): : 527 - 538
  • [8] Wear at the Implant-Abutment Interface of Zirconia Abutments Manufactured by Three CAD/CAM Systems
    Pinheiro Tannure, Ana Luiza
    Cunha, Alfredo Goncalves
    Borges Junior, Luiz Antonio
    da Silva Concilio, Lais Regiane
    Claro Neves, Ana Christina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (06) : 1241 - 1250
  • [9] Diagnostic value of Digital Radiography in Gap Detection of Implant-Abutment Connection with Zirconia Abutments in Different vertical X-ray Projection Angles
    Alikhasi, Marzieh
    Salehi, Alireza
    Memarian, Maryam
    Tabesh, Mahtab
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (05) : ZC15 - ZC18
  • [10] The survival of dental implants with different implant-abutment connection systems
    Szpak, Piotr
    Szymanska, Jolanta
    CURRENT ISSUES IN PHARMACY AND MEDICAL SCIENCES, 2016, 29 (01) : 11 - 13