Total Hip Arthroplasty Digital Templating: Size Predicting Ability and Interobserver Variability

被引:9
|
作者
Montiel, Veronica [1 ]
Troncoso, Santiago [1 ]
Valenti-Azcarate, Andres [1 ]
Valenti-Nin, Juan Ramon [1 ]
Lamo-Espinosa, Jose Maria [1 ]
机构
[1] Clin Univ Navarra, Dept Orthoped Surg & Traumatol, Ave Pio 12,36, Navarra 31008, Spain
关键词
Digital templating; Hip arthroplasty; Total hip arthroplasty; Total hip arthroplasty preoperative planning; LEG LENGTH INEQUALITY; COST-EFFECTIVENESS; ACCURACY; REPLACEMENT; QUALITY;
D O I
10.1007/s43465-020-00217-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background During the last century, total hip arthroplasties have become more popular. They have had a huge impact on the quality of life, pain, range of motion, social interaction, and psychological well-being. A number of studies have emphasized the importance of using templates to choose the appropriate implant size when planning the surgery. Our aim is to use MediCad(R)software to analyze the ability of the digital template system MediCad(R)to predict the size of the implant needed in total hip arthroplasties. Materials and Methods An arthroplasty preoperative plan was created according to the MediCad(R)software guidelines, on anteroposterior hip X-ray by one junior resident, one senior resident, and three experienced hip surgeons. Results The median size accuracy was 0.7 (range: 0.27-0.87) for the cup, 0.73 (range: 0.36-0.83) for the stem, and 0.28 (range: -0.14-0.69) for the neck. Interobserver reliability was good (kappa > 0.4) and stronger when measuring the stem than when doing so with the cup. Conclusion: Digital preoperative total hip arthroplasty planning is a good method for predicting component size, restoring hip anatomy (vertical offset and horizontal offset), with good interobserver reliability.
引用
收藏
页码:840 / 847
页数:8
相关论文
共 50 条
  • [21] Evaluation of the Accuracy and Use of X-Ray Markers in Digital Templating for Total Hip Arthroplasty
    Bayne, Christopher O.
    Krosin, Michael
    Barber, Thomas C.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (03) : 407 - 413
  • [22] Digital templating in total hip arthroplasty using contralateral healthy hip results in decreased accuracy
    Shichman, Ittai
    Shaked, Or
    Morgan, Samuel
    Garceau, Simon
    Snir, Nimrod
    Warschawski, Yaniv
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (03): : 427 - 433
  • [23] Influence of calibration on digital templating of hip arthroplasty
    Christoph Kolja Boese
    Sebastian Wilhelm
    Stefan Haneder
    Philipp Lechler
    Peer Eysel
    Jan Bredow
    International Orthopaedics, 2019, 43 : 1799 - 1805
  • [24] Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system
    Ari Bertz
    Kari Indrekvam
    Mohamed Ahmed
    Erling Englund
    Arkan S. Sayed-Noor
    Skeletal Radiology, 2012, 41 : 1245 - 1249
  • [25] Predicting Implant Size in Total Hip Arthroplasty
    Chen, James B.
    Diane, Alioune
    Lyman, Stephen
    Chiu, Yu-fen
    Blevins, Jason L.
    Westrich, Geoffrey H.
    ARTHROPLASTY TODAY, 2022, 15 : 210 - 214
  • [26] Radiographic templating of total hip arthroplasty for femoral neck fractures
    Lakstein, Dror
    Bachar, Ira
    Debi, Ronen
    Lubovsky, Omri
    Cohen, Ornit
    Tan, Zachary
    Atoun, Ehud
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (04) : 831 - 836
  • [27] Femoroacetabular offset restoration in total hip arthroplasty; Digital templating a short stem vs a conventional stem
    de Waard, Sheryl
    Verboom, Tom
    Bech, Niels Hendrik
    Sierevelt, Inger N.
    Kerkhoffs, Gino M.
    Haverkamp, Daniel
    WORLD JOURNAL OF ORTHOPEDICS, 2022, 13 (02): : 139 - 149
  • [28] The Accuracy of Digital Templating for Primary Total Hip Arthroplasty: Is There a Difference Between Direct Anterior and Posterior Approaches?
    Shemesh, Shai S.
    Robinson, Jonathan
    Keswani, Aakash
    Bronson, Michael J.
    Moucha, Calin S.
    Chen, Darwin
    JOURNAL OF ARTHROPLASTY, 2017, 32 (06) : 1884 - 1889
  • [29] Does two dimensional templating allow for the use of reduced-size ancillaries in total hip arthroplasty?
    Heliere, Gregoire
    David, Guillaume
    Cypel, Sarah
    Steiger, Vincent
    Ducellier, Florian
    Rony, Louis
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (10) : 2553 - 2559
  • [30] Digital templating in total hip arthroplasty in the NHS: 'computer says no...'
    Jeyaseelan, Luckshmana
    Ward, Jonathan
    Eleftheriou, Kyriacos
    Cobb, J.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2011, 21 (06) : 397 - 399