Total Hip Arthroplasty Digital Templating: Size Predicting Ability and Interobserver Variability

被引:9
|
作者
Montiel, Veronica [1 ]
Troncoso, Santiago [1 ]
Valenti-Azcarate, Andres [1 ]
Valenti-Nin, Juan Ramon [1 ]
Lamo-Espinosa, Jose Maria [1 ]
机构
[1] Clin Univ Navarra, Dept Orthoped Surg & Traumatol, Ave Pio 12,36, Navarra 31008, Spain
关键词
Digital templating; Hip arthroplasty; Total hip arthroplasty; Total hip arthroplasty preoperative planning; LEG LENGTH INEQUALITY; COST-EFFECTIVENESS; ACCURACY; REPLACEMENT; QUALITY;
D O I
10.1007/s43465-020-00217-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background During the last century, total hip arthroplasties have become more popular. They have had a huge impact on the quality of life, pain, range of motion, social interaction, and psychological well-being. A number of studies have emphasized the importance of using templates to choose the appropriate implant size when planning the surgery. Our aim is to use MediCad(R)software to analyze the ability of the digital template system MediCad(R)to predict the size of the implant needed in total hip arthroplasties. Materials and Methods An arthroplasty preoperative plan was created according to the MediCad(R)software guidelines, on anteroposterior hip X-ray by one junior resident, one senior resident, and three experienced hip surgeons. Results The median size accuracy was 0.7 (range: 0.27-0.87) for the cup, 0.73 (range: 0.36-0.83) for the stem, and 0.28 (range: -0.14-0.69) for the neck. Interobserver reliability was good (kappa > 0.4) and stronger when measuring the stem than when doing so with the cup. Conclusion: Digital preoperative total hip arthroplasty planning is a good method for predicting component size, restoring hip anatomy (vertical offset and horizontal offset), with good interobserver reliability.
引用
收藏
页码:840 / 847
页数:8
相关论文
共 50 条
  • [1] Total Hip Arthroplasty Digital Templating: Size Predicting Ability and Interobserver Variability
    Veronica Montiel
    Santiago Troncoso
    Andrés Valentí-Azcárate
    Juan Ramón Valentí-Nin
    Jose María Lamo-Espinosa
    Indian Journal of Orthopaedics, 2020, 54 : 840 - 847
  • [2] The accuracy of digital templating in uncemented total hip arthroplasty
    Holzer, Lukas A.
    Scholler, Georg
    Wagner, Stefan
    Friesenbichler, Joerg
    Maurer-Ertl, Werner
    Leithner, Andreas
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (02) : 263 - 268
  • [3] Effect of Body Mass Index on Digital Templating for Total Hip Arthroplasty
    Sershon, Robert A.
    Diaz, Alejandro
    Bohl, Daniel D.
    Levine, Brett R.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (03) : 1024 - 1026
  • [4] Calibration Marker Position in Digital Templating of Total Hip Arthroplasty
    Boese, Christoph K.
    Bredow, Jan
    Dargel, Jens
    Eysel, Peer
    Geiges, Hansjoerg
    Lechler, Philipp
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04) : 883 - 887
  • [5] Influence of calibration on digital templating of hip arthroplasty
    Boese, Christoph Kolja
    Wilhelm, Sebastian
    Haneder, Stefan
    Lechler, Philipp
    Eysel, Peer
    Bredow, Jan
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (08) : 1799 - 1805
  • [6] The accuracy of digital templating in uncemented total hip arthroplasty
    Lukas A. Holzer
    Georg Scholler
    Stefan Wagner
    Jörg Friesenbichler
    Werner Maurer-Ertl
    Andreas Leithner
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 263 - 268
  • [7] Calibration Markers for Digital Templating in Total Hip Arthroplasty
    Boese, Christoph Kolja
    Lechler, Philipp
    Rose, Leonard
    Dargel, Jens
    Oppermann, Johannes
    Eysel, Peer
    Geiges, Hansjoerg
    Bredow, Jan
    PLOS ONE, 2015, 10 (07):
  • [8] Precision of preoperative digital templating in total hip arthroplasty
    Efe, Turgay
    El Zayat, Bilal Farouk
    Heyse, Thomas J.
    Timmesfeld, Nina
    Fuchs-Winkelmann, Susanne
    Schmitt, Jan
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (05): : 616 - 621
  • [9] The Accuracy of Digital Templating in Uncemented Total Hip Arthroplasty
    Gamble, Patrick
    de Beer, Justin
    Petruccelli, Danielle
    Winemaker, Mitchell
    JOURNAL OF ARTHROPLASTY, 2010, 25 (04) : 529 - 532
  • [10] The accuracy of digital templating in cementless total hip arthroplasty in dysplastic hips
    Kristoffersson, Emelie
    Otten, Volker
    Crnalic, Sead
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)