Automated calculations for computing the sample-limited spatial resolution in (scanning) transmission electron microscopy

被引:5
|
作者
Zulfiqar, Abid [1 ,2 ]
Azim, Sana [1 ]
Ortega, Eduardo [1 ]
de Jonge, Niels [1 ,2 ]
机构
[1] INM Leibniz Inst New Mat, D-66123 Saarbrucken, Germany
[2] Saarland Univ, Dept Phys, D-66123 Saarbrucken, Germany
关键词
TEM; STEM; Electron scattering; Spatial resolution; Electron dose; Computer model;
D O I
10.1016/j.ultramic.2022.113611
中图分类号
TH742 [显微镜];
学科分类号
摘要
MATLAB scripts were designed to compute the sample-limited spatial resolution in transmission electron mi-croscopy (TEM) and scanning TEM (STEM) as a function of different microscopy parameters including the electron dose eD, sample geometry, and materials parameters. The scripts can be used to select the optimum microscopy modality and optimize the experimental conditions to achieve the best possible resolution consid-ering the limitations set by both the electron optics and the examined sample. The resolution can be computed as function of the objective opening semi-angle alpha for TEM and detector opening semi-angle beta for STEM. Optional code for computing a range over the sample thickness t or eD are provided as well, whereby the opening angle is optimized for each data point. The spatial resolution depends on the type of material of the nanoscale object (for example, gold or carbon nanoparticles), the type of matrix holding the objects (for example, water or ice), the depth of the nanoscale object inside the matrix, and eD. The optimization is consistent with the typical situation that carbon nanoparticles are best examined with TEM embedded in a thin matrix (t = 0.1 mu m), while STEM is better suited for high atomic number objects such as gold nanoparticles in water, irrespective of t. The script also calculates the reduction of beam broadening in thick samples (t > 1 mu m) using bright field STEM.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Theory of the spatial resolution of (scanning) transmission electron microscopy in liquid water or ice layers
    de Jonge, Niels
    ULTRAMICROSCOPY, 2018, 187 : 113 - 125
  • [2] Spatial resolution in transmission electron microscopy
    Egerton, R. F.
    Watanabe, M.
    MICRON, 2022, 160
  • [3] Spatial resolution and information transfer in scanning transmission electron microscopy
    Peng, Yiping
    Oxley, Mark P.
    Lupini, Andrew R.
    Chisholm, Matthew F.
    Pennycook, Stephen J.
    MICROSCOPY AND MICROANALYSIS, 2008, 14 (01) : 36 - 47
  • [4] The influence of chromatic aberration on the dose-limited spatial resolution of transmission electron microscopy
    Ortega E.
    Boothroyd C.
    de Jonge N.
    Ultramicroscopy, 2021, 230
  • [5] Automated electron tomography with scanning transmission electron microscopy
    Feng, Jianglin
    Somlyo, Andrew P.
    Somlyo, Avril V.
    Shao, Zhifeng
    JOURNAL OF MICROSCOPY, 2007, 228 (03) : 406 - 412
  • [6] Spatial and phase resolution in electron microscopy
    Ishikawa, Ryo
    Morishita, Shigeyuki
    Tanigaki, Toshiaki
    Shibata, Naoya
    Ikuhara, Yuichi
    MICROSCOPY, 2023, 72 (02) : 78 - 96
  • [7] Practical spatial resolution of electron energy loss spectroscopy in aberration corrected scanning transmission electron microscopy
    Shah, A. B.
    Ramasse, Q. M.
    Wen, J. G.
    Bhattacharya, A.
    Zuo, J. M.
    MICRON, 2011, 42 (06) : 539 - 546
  • [8] Interlacing in Atomic Resolution Scanning Transmission Electron Microscopy
    Peters, Jonathan J. P.
    Mullarkey, Tiarnan
    Gott, James A.
    Nelson, Elizabeth
    Jones, Lewys
    MICROSCOPY AND MICROANALYSIS, 2023, 29 (04) : 1373 - 1379
  • [9] The Influence of Beam Broadening on the Spatial Resolution of Annular Dark Field Scanning Transmission Electron Microscopy
    de Jonge, Niels
    Verch, Andreas
    Demers, Hendrix
    MICROSCOPY AND MICROANALYSIS, 2018, 24 (01) : 8 - 16
  • [10] The Probe Profile and Lateral Resolution of Scanning Transmission Electron Microscopy of Thick Specimens
    Demers, Hendrix
    Ramachandra, Ranjan
    Drouin, Dominique
    de Jonge, Niels
    MICROSCOPY AND MICROANALYSIS, 2012, 18 (03) : 582 - 590