Effect of moisture uptake on the repeatability of near infrared spectroscopy analyses of ewe milk using the dry extract system for infrared (DESIR) method

被引:7
作者
Nunez-Sanchez, Nieves [1 ,2 ]
Manuel Serradilla, Juan [1 ]
Luis Ares, Jose [3 ]
Garrido-Varo, Ana [1 ]
机构
[1] Univ Cordoba, ETSIAM, Dept Anim Prod, E-14071 Cordoba, Spain
[2] NIRSoluciones SL, Cordoba 14006, Spain
[3] IFAPA Ctr Hinojosa del Duque, Cordoba 14270, Spain
关键词
near infrared spectroscopy; NIR; DESIR; desiccator; repeatability; ewe milk; chemical composition; water absorption;
D O I
10.1255/jnirs.802
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
This paper reports a study carried out to determine the effect of post-filter-drying moisture uptake on the repeatability of NIR spectroscopy analyses of ewe milk using the dry-extract system for infrared (DESIR). The study assessed the spectral repeatability of the method and the effect of moisture uptake on that repeatability, using graphical representations and root mean squared (RMS) error between spectra, as well as multivariate Mahalanobis distances (GH values) and predicted constituent values (protein, fat and dry matter). The spectral repeatability of this method of dried milk analysis using g[ass-fibre fitters was very high, both spectrally per se [RMS MEAN = 3.914 mu log (1/R) and STD = 4.126 mu log (1/1R)] and in terms of NIR spectroscopy prediction of chemical components and of the Mahalanobis distance. Using a single filter per milk sample is thus considered sufficient to guarantee the required accuracy and precision of the DESIR method. Differences between spectra due to the presence or absence of air exposure [STD = 6446 mu log (1/R)] were greater than the method repeatability error. Predictions of protein, fat and dry matter were significantly higher for air-exposed filters, due to moisture uptake; the increase in GH values for air-exposed fitters was highly significant, suggesting that milk samples to be analysed using the DESIR method should be stored in a desiccator after drying and before NIR analysis and not left exposed to air.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 27 条
[1]  
ANGULO C, 1997, THESIS U CORDOBA COR
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], NEAR INFRARED TECHNO
[4]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[5]   Correction of the temperature effect on near infrared calibration - application to soluble solid content prediction [J].
Chauchard, F ;
Roger, JM ;
Bellon-Maurel, V .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2004, 12 (03) :199-205
[6]  
DEBRABANT MP, 1990, P 3 INT NIRS C, P577
[7]  
Diaz-Carrillo E., 1993, Journal of Near Infrared Spectroscopy, V1, P141
[8]  
Evans D. G., 1993, Journal of Near Infrared Spectroscopy, V1, P33
[9]   The transfer of fatty acid calibration equations using four sets of unsealed liquid standardisation samples [J].
García-Olmo, J ;
Garrido-Varo, A ;
De Pedro, E .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2001, 9 (01) :49-62
[10]  
Garrido A., 2004, NEAR INFRARED SPECTR, V44, P487