Quantitative comparison of the OCT imaging depth at 1300 nm and 1600 nm

被引:77
作者
Kodach, V. M. [1 ]
Kalkman, J.
Faber, D. J. [1 ]
van Leeuwen, T. G. [2 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Ophthalmol, NL-1100 DE Amsterdam, Netherlands
[2] Univ Twente, MIRA Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
关键词
OPTICAL-COHERENCE TOMOGRAPHY; MU-M; SCATTERING; TISSUE; ATTENUATION;
D O I
10.1364/BOE.1.000176
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
One of the present challenges in optical coherence tomography (OCT) is the visualization of deeper structural morphology in biological tissues. Owing to a reduced scattering, a larger imaging depth can be achieved by using longer wavelengths. In this work, we analyze the OCT imaging depth at wavelengths around 1300 nm and 1600 nm by comparing the scattering coefficient and OCT imaging depth for a range of Intralipid concentrations at constant water content. We observe an enhanced OCT imaging depth for 1600 nm compared to 1300 nm for Intralipid concentrations larger than 4 vol.%. For higher Intralipid concentrations, the imaging depth enhancement reaches 30%. The ratio of scattering coefficients at the two wavelengths is constant over a large range of scattering coefficients and corresponds to a scattering power of 2.8 +/- 0.1. Based on our results we expect for biological tissues an increase of the OCT imaging depth at 1600 nm compared to 1300 nm for samples with high scattering power and low water content. (C) 2010 Optical Society of America
引用
收藏
页码:176 / 185
页数:10
相关论文
共 25 条
[1]  
[Anonymous], REFR IND DAT
[2]   OPTICAL COHERENCE TOMOGRAPHIC IMAGING OF HUMAN TISSUE AT 1.55 μM AND 1.81 μM USING ER- AND TM-DOPED FIBER SOURCES [J].
Bouma, Brett E. ;
Nelson, Lynn E. ;
Tearney, Guillermo J. ;
Jones, David J. ;
Brezinski, Mark E. ;
Fujimoto, James G. .
JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (01) :76-79
[3]   Comparative study of optical sources in the near infrared for optical coherence tomography applications [J].
Carrion, Lionel ;
Lestrade, Michel ;
Xu, Zhiqiang ;
Touma, Gaby ;
Maciejko, Romain ;
Bertrand, Michel .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (01)
[4]   A primary method for determination of optical parameters of turbid samples and application to intralipid between 550 and 1630nm [J].
Chen, Cheng ;
Lu, Jun Q. ;
Ding, Huafeng ;
Jacobs, Kenneth M. ;
Du, Yong ;
Hu, Xin-Hua .
OPTICS EXPRESS, 2006, 14 (16) :7420-7435
[5]   Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source [J].
Choma, MA ;
Hsu, K ;
Izatt, JA .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
[6]   Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography [J].
Faber, DJ ;
Mik, EG ;
Aalders, MCG ;
van Leeuwen, TG .
OPTICS LETTERS, 2005, 30 (09) :1015-1017
[7]   Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography [J].
Faber, DJ ;
van der Meer, FJ ;
Aalders, MCG ;
van Leeuwen, TG .
OPTICS EXPRESS, 2004, 12 (19) :4353-4365
[8]   Optical properties of high-density dispersions of particles:: application to intralipid solutions [J].
Giusto, A ;
Saija, R ;
Iatì, MA ;
Denti, P ;
Borghese, F ;
Sindoni, OI .
APPLIED OPTICS, 2003, 42 (21) :4375-4380
[9]   OPTICAL-CONSTANTS OF WATER IN 200-NM TO 200-MUM WAVELENGTH REGION [J].
HALE, GM ;
QUERRY, MR .
APPLIED OPTICS, 1973, 12 (03) :555-563
[10]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181