Evaluation of paediatric computed tomography imaging for brain, and abdomen procedures

被引:12
作者
Almujally, Abdullah [1 ]
Tamam, Nissren [2 ]
Sulieman, Abdelmoneim [3 ]
Tai, Duong Thanh [4 ]
Omer, Hiba [5 ]
Abuhadi, Nouf [6 ]
Salah, Hassan [7 ]
Mattar, Essam [8 ]
Khandaker, Mayeen Uddin [9 ,10 ]
Bradley, David [9 ,11 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Biomed Phys, Riyadh, Saudi Arabia
[2] Princess Nourah bint Abdulrahman Univ, Coll Sci, Dept Phys, POB 84428, Riyadh 11671, Saudi Arabia
[3] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, POB 422, Alkharj 11942, Saudi Arabia
[4] Nguyen Tat Thanh Univ, Fac Med, Dept Med Phys, 298-300A Nguyen Tat Thanh St,Ward 13,Dist 4, Ho Chi Minh City, Vietnam
[5] Imam Abdulrahman Bin Faisal Univ, Dept Basic Sci, Deanship Preparatory Year & Supporting Studies, POB 1982, Dammam 34212, Saudi Arabia
[6] Jazan Univ, Coll Appl Med Sci, Dept Diagnost Radiol, Jazan, Saudi Arabia
[7] INAYA Med Collage, Nucl Med Dept, Riyadh, Saudi Arabia
[8] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 10219, Riyadh 11433, Saudi Arabia
[9] Sunway Univ, Ctr Appl Phys & Radiat Technol, Sch Engn & Technol, Bandar Sunway 47500, Selangor, Malaysia
[10] Daffodil Int Univ, Fac Sci & Informat Technol, Dept Gen Educ Dev, DIU Rd, Dhaka 1341, Bangladesh
[11] Univ Surrey, Ctr Nucl & Radiat Phys, Dept Phys, Guildford GU2, Surrey, England
关键词
Radiology; CT imaging; Radiation dosimetry; Pediatric imaging; CT; ANGIOGRAPHY; CHEST; RISK;
D O I
10.1016/j.radphyschem.2022.110271
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Computed tomography (CT) are often used for adult and pediatric patients. This is basically due to its powerful diagnostic capabilities in providing the tiniest details of pathologies in the body. Nevertheless, this detailed and accurate imaging occurs at the expense of the high doses received by the patients, although in general, the benefits outweighs the risks precisely of malignancy. Pediatrics are radiosensitive more than adults due to their longer life expectancy and their rapidly dividing cells.This study aims at measuring and evaluating pediatric patient doses in four hospitals equipped with 16, 20 and 128 CT detectors. Forty-eight pediatric patients who underwent brain (72.7%) and abdomen (36.3%) Computed Tomography are included in this study. Data includes CTDIvol (mGy) and DLP (mGy.cm). CTDOSE computer software which is based on Monte Carlo simulations was used to calculate the effective and organ equivalent doses (mSv).The CTDIvol (mGy) per procedure range was 11.0-95.0 mGy for brain CT and 3.0-30.0 mGy for abdomen CT. DLP on the other hand ranged between 129.0 and 2510.0 mGy cm for brain CT and 84.0-1604.0 for abdomen CT. The high doses were attributed to the fact that the protocols used for pediatric patients were the adult protocols, not bearing in mind the high radio-sensitivity of the pediatrics. Establishing a protocol for pediatric CT is hence of great importance to prevent them from receiving unnecessary high doses which may eventually cause cancer.
引用
收藏
页数:5
相关论文
共 26 条
  • [1] Patient radiation biological risk in computed tomography angiography procedure
    Alkhorayef, M.
    Babikir, E.
    Alrushoud, A.
    Al-Mohammed, H.
    Sulieman, A.
    [J]. SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2017, 24 (02) : 235 - 240
  • [2] Patients Radiation Risks from Computed Tomography Lymphography
    Almujally, Abdullah
    Sulieman, Abdelmoneim
    Calliada, Fabrizio
    [J]. JOURNAL OF CLINICAL IMAGING SCIENCE, 2020, 10
  • [3] Evaluation of pediatric radiation doses in computed tomography procedures in the Kingdom of Saudi Arabia
    Alzimami, K.
    Sulieman, A.
    Omer, Hiba
    Jambi, Layal K.
    Alfuraih, A.
    Al Hossain, N.
    Babikir, E.
    Alkhorayef, M.
    Khandaker, Mayeen Uddin
    Bradley, D. A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [4] Atac G.K., 2015, PATIENT DOSES CT EXA, V21, P5
  • [5] Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children
    Aw-Zoretic, J.
    Seth, D.
    Katzman, G.
    Sammet, S.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1920 - 1924
  • [6] Beir V.I.I., 2006, HLTH RISKS EXP LOW L, P424
  • [7] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [8] Radiation dose evaluation of pediatric patients in CT brain examination: multi-center study
    Eddy, Fotso Kamdem
    Ngano, Samba Odette
    Jerve, Fotue Alain
    Serge, Abogo
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] PURSUING OPTIMAL RADIATION DOSE IN PEDIATRIC CARDIAC CT: A REPORT FROM UNIVERSITY HOSPITAL LEUVEN
    Hustings, Nico
    Bosmans, Hilde
    Dymarkowski, Steven
    [J]. RADIATION PROTECTION DOSIMETRY, 2022, 198 (03) : 139 - 146
  • [10] ICRP 102, 2007, Ann. ICRP, V37