A Canonical Biomechanical Vocal Fold Model

被引:3
作者
Bhattacharya, Pinaki [1 ]
Siegmund, Thomas H. [1 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
关键词
Vocal fold; Geometric model; Tissue biomechanical properties; Eigenfrequencies; MECHANICAL MODEL; OBLIQUE GLOTTIS; FLOW-THROUGH; LARYNX; PRESSURE; PHONATION; SIMULATION; ONSET;
D O I
10.1016/j.jvoice.2011.09.001
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
The present article aimed at constructing a canonical geometry of the human vocal fold (VF) from subject-specific image slice data. A computer-aided design approach automated the model construction. A subject-specific geometry available in literature, three abstractions (which successively diminished in geometric detail) derived from it, and a widely used quasi two-dimensional VF model geometry were used to create computational models. The first three natural frequencies of the models were used to characterize their mechanical response. These frequencies were determined for a representative range of tissue biomechanical properties, accounting for underlying VF histology. Compared with the subject-specific geometry model (baseline), a higher degree of abstraction was found to always correspond to a larger deviation in model frequency (up to 50% in the relevant range of tissue biomechanical properties). The model we deemed canonical was optimally abstracted, in that it significantly simplified the VF geometry compared with the baseline geometry but can be recalibrated in a consistent manner to match the baseline response. Models providing only a marginally higher degree of abstraction were found to have significant deviation in predicted frequency response. The quasi two-dimensional model presented an extreme situation: it could not be recalibrated for its frequency response to match the subject-specific model. This deficiency was attributed to complex support conditions at anterior-posterior extremities of the VFs, accentuated by further issues introduced through the tissue biomechanical properties. In creating canonical models by leveraging advances in clinical imaging techniques, the automated design procedure makes VF modeling based on subject-specific geometry more realizable.
引用
收藏
页码:535 / 547
页数:13
相关论文
共 54 条
[21]   Comparison of Acceleration and Impact Stress as Possible Loading Factors in Phonation: A Computer Modeling Study [J].
Horacek, Jaromir ;
Laukkanen, Anne-Maria ;
Sidlof, Petr ;
Murphy, Peter ;
Svec, Jan G. .
FOLIA PHONIATRICA ET LOGOPAEDICA, 2009, 61 (03) :137-145
[22]   Three-dimensional Educational Computer Model of the Larynx Voicing a New Direction [J].
Hu, Amanda ;
Wilson, Tim ;
Ladak, Hanif ;
Haase, Peter ;
Fung, Kevin .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2009, 135 (07) :677-681
[23]   A three-dimensional model of vocal fold abduction/adduction [J].
Hunter, EJ ;
Titze, IR ;
Alipour, F .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (04) :1747-1759
[24]   SYNTHESIS OF VOICED SOUNDS FROM A 2-MASS MODEL OF VOCAL CORDS [J].
ISHIZAKA, K ;
FLANAGAN, JL .
BELL SYSTEM TECHNICAL JOURNAL, 1972, 51 (06) :1233-+
[25]   THYROPLASTY AS A NEW PHONOSURGICAL TECHNIQUE [J].
ISSHIKI, N ;
MORITA, H ;
OKAMURA, H ;
HIRAMOTO, M .
ACTA OTO-LARYNGOLOGICA, 1974, 78 (5-6) :451-457
[26]   Spatially varying properties of the vocal ligament contribute to its eigenfrequency response [J].
Kelleher, J. E. ;
Zhang, K. ;
Siegmund, T. ;
Chan, R. W. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2010, 3 (08) :600-609
[27]   Optical measurements of vocal fold tensile properties: Implications for phonatory mechanics [J].
Kelleher, Jordan E. ;
Siegmund, Thomas ;
Chan, Roger W. ;
Henslee, Erin A. .
JOURNAL OF BIOMECHANICS, 2011, 44 (09) :1729-1734
[28]   LARYNX - MR IMAGING AT 2.35-T [J].
KIKINIS, R ;
WOLFENSBERGER, M ;
BOESCH, C ;
MARTIN, E .
RADIOLOGY, 1989, 171 (01) :165-169
[29]   Theoretical assessment of unsteady aerodynamic effects in phonation [J].
Krane, Michael H. ;
Wei, Timothy .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 120 (03) :1578-1588
[30]  
OESTREICHER HL, 1951, J ACOUST SOC AM, V23, P707, DOI 10.1121/1.1906828