Visual performance and optical quality with soft lenses in keratoconus patients

被引:53
作者
Jinabhai, Amit [1 ,2 ]
Radhakrishnan, Hema [1 ]
Tromans, Cindy [3 ]
O'Donnell, Clare [1 ,2 ,4 ]
机构
[1] Univ Manchester, Fac Life Sci, Manchester, Lancs, England
[2] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
[3] Cent Manchester Univ Hosp NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
[4] Optegra Manchester Eye Hosp, Manchester, Lancs, England
关键词
coma RMS; higher-order aberrations; keratoconus; RGP lenses; soft contact lenses; visual acuity; COLLABORATIVE LONGITUDINAL EVALUATION; HIGHER-ORDER ABERRATIONS; CONTACT-LENSES; ON-EYE; OCULAR ABERRATIONS; OFF-EYE; ACUITY; COMFORT; SIGNS;
D O I
10.1111/j.1475-1313.2011.00889.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess visual performance and ocular aberrations in keratoconic patients using toric soft contact lenses (SCL), rigid-gas-permeable (RGP) contact lenses and spectacle lens correction. Methods: Twenty-two keratoconus patients (16 RGP lens wearers and six spectacle wearers) were fitted with toric SCL. Ocular aberrations were measured with and without the patients habitual RGP lenses and with the SCL in place. In the spectacle wearers, aberrations were measured with and without the SCL. Visual performance (high- and low-contrast visual acuity) was evaluated with the patients habitual correction and with the SCL. Results: In the RGP lens wearers both the habitual lenses and the toric SCL significantly reduced coma, trefoil, 3rd-order, 4th-order cylinder and higher-order root-mean-square (RMS) aberrations (p = 0.015). In the spectacle wearers the toric SCL significantly reduced coma, 3rd-order and higher-order RMS aberrations (p = 0.01). The patients habitual RGP lenses gave better low-contrast acuity (p = 0.006) compared to the toric SCL; however, no significant difference was found between lens types for high-contrast acuity (p = 0.10). In the spectacle wearers no significant differences in visual performance measurements were found between the patients spectacles and the toric SCL (p = 0.06). Conclusion: The results show that RGP lenses provided superior visual performances and greater reduction of 3rd-order aberrations compared to toric SCL in this group of keratoconic patients. In the spectacle-wearing group, visual performance with the toric SCL was found to be comparable to that measured with spectacles. Nevertheless, with the exception of spherical aberration, the toric SCL were successful in significantly reducing uncorrected higher-order aberrations.
引用
收藏
页码:100 / 116
页数:17
相关论文
共 71 条
[11]   ECZEMA AND KERATOCONUS [J].
COPEMAN, PWM .
BRITISH MEDICAL JOURNAL, 1965, 2 (5468) :977-&
[12]   On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry [J].
Dorronsoro, C ;
Barbero, S ;
Llorente, L ;
Marcos, S .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (02) :115-125
[13]   Rigid contact lens fitting relationships in keratoconus [J].
Edrington, TB ;
Szczotka, LB ;
Barr, JT ;
Achtenberg, JF ;
Burger, DS ;
Janoff, AM ;
Olafsson, HE ;
Chun, MW ;
Boyle, JW ;
Gordon, MO ;
Zadnik, K .
OPTOMETRY AND VISION SCIENCE, 1999, 76 (10) :692-699
[14]   Variables affecting rigid contact lens comfort in the collaborative longitudinal evaluation of keratoconus (CLEK) study [J].
Edrington, TB ;
Gundel, RE ;
Libassi, DP ;
Wagner, H ;
Pierce, GE ;
Walline, JJ ;
Barr, JT ;
Olafsson, HE ;
Steger-May, K ;
Achtenberg, J ;
Wilson, BS ;
Gordon, MO ;
Zadnik, K .
OPTOMETRY AND VISION SCIENCE, 2004, 81 (03) :182-188
[15]   Effect of 3rd-order aberrations on human vision [J].
Fernandez-Sanchez, Vicente ;
Ponce, M. Eugenia ;
Lara, Francisco ;
Montes-Mico, Robert ;
Castejon-Mochon, Jose F. ;
Lopez-Gil, Norberto .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (08) :1339-1344
[16]   A comparison of two methods of evaluating cornea-to-contact lens base curve fluorescein patterns in keratoconus [J].
Fink, BA ;
Barr, JT ;
Edrington, TB ;
Pierce, GE ;
Schechtman, KB ;
Rah, MJ ;
Flom, R ;
Zadnik, K .
OPTOMETRY AND VISION SCIENCE, 2001, 78 (08) :589-598
[17]  
GASSET AR, 1978, ANN OPHTHALMOL, V10, P991
[18]  
Gonzalez-Meijome Jose M, 2006, Eye Contact Lens, V32, P143, DOI 10.1097/01.icl.0000179707.85290.f4
[19]  
Griffiths Monique, 1998, CLAO Journal, V24, P76
[20]   Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations [J].
Guirao, A ;
Williams, DR ;
Cox, IG .