Visual performance and optical quality with soft lenses in keratoconus patients

被引:53
作者
Jinabhai, Amit [1 ,2 ]
Radhakrishnan, Hema [1 ]
Tromans, Cindy [3 ]
O'Donnell, Clare [1 ,2 ,4 ]
机构
[1] Univ Manchester, Fac Life Sci, Manchester, Lancs, England
[2] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
[3] Cent Manchester Univ Hosp NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
[4] Optegra Manchester Eye Hosp, Manchester, Lancs, England
关键词
coma RMS; higher-order aberrations; keratoconus; RGP lenses; soft contact lenses; visual acuity; COLLABORATIVE LONGITUDINAL EVALUATION; HIGHER-ORDER ABERRATIONS; CONTACT-LENSES; ON-EYE; OCULAR ABERRATIONS; OFF-EYE; ACUITY; COMFORT; SIGNS;
D O I
10.1111/j.1475-1313.2011.00889.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess visual performance and ocular aberrations in keratoconic patients using toric soft contact lenses (SCL), rigid-gas-permeable (RGP) contact lenses and spectacle lens correction. Methods: Twenty-two keratoconus patients (16 RGP lens wearers and six spectacle wearers) were fitted with toric SCL. Ocular aberrations were measured with and without the patients habitual RGP lenses and with the SCL in place. In the spectacle wearers, aberrations were measured with and without the SCL. Visual performance (high- and low-contrast visual acuity) was evaluated with the patients habitual correction and with the SCL. Results: In the RGP lens wearers both the habitual lenses and the toric SCL significantly reduced coma, trefoil, 3rd-order, 4th-order cylinder and higher-order root-mean-square (RMS) aberrations (p = 0.015). In the spectacle wearers the toric SCL significantly reduced coma, 3rd-order and higher-order RMS aberrations (p = 0.01). The patients habitual RGP lenses gave better low-contrast acuity (p = 0.006) compared to the toric SCL; however, no significant difference was found between lens types for high-contrast acuity (p = 0.10). In the spectacle wearers no significant differences in visual performance measurements were found between the patients spectacles and the toric SCL (p = 0.06). Conclusion: The results show that RGP lenses provided superior visual performances and greater reduction of 3rd-order aberrations compared to toric SCL in this group of keratoconic patients. In the spectacle-wearing group, visual performance with the toric SCL was found to be comparable to that measured with spectacles. Nevertheless, with the exception of spherical aberration, the toric SCL were successful in significantly reducing uncorrected higher-order aberrations.
引用
收藏
页码:100 / 116
页数:17
相关论文
共 71 条
[1]   Tear Film Surface Quality With Soft Contact Lenses Using Dynamic-Area High-Speed Videokeratoscopy [J].
Alonso-Caneiro, David ;
Iskander, Robert ;
Collins, Michael J. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (05) :227-231
[2]   Factors associated with corneal scarring in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study [J].
Barr, JT ;
Zadnik, K ;
Wilson, BS ;
Edrington, TB ;
Everett, DF ;
Fink, BA ;
Shovlin, JP ;
Weissman, BA ;
Siegmund, K ;
Gordon, MO .
CORNEA, 2000, 19 (04) :501-507
[3]   Atopy and keratoconus: a multivariate analysis [J].
Bawazeer, AM ;
Hodge, WG ;
Lorimer, B .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (08) :834-836
[4]   Visual performance and comfort with the Rose K lens for keratoconus [J].
Betts, AM ;
Mitchell, GL ;
Zadnik, K .
OPTOMETRY AND VISION SCIENCE, 2002, 79 (08) :493-501
[5]   30 years of contact lens prescribing for keratoconic patients in Turkey [J].
Bilgin, Lale K. ;
Yilmaz, Senay ;
Araz, Bilge ;
Yuksel, Serdar B. ;
Sezen, Turan .
CONTACT LENS & ANTERIOR EYE, 2009, 32 (01) :16-21
[6]   MULTIPLE SIGNIFICANCE TESTS - THE BONFERRONI METHOD .10. [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6973) :170-170
[7]  
BUXTON J.N., 1978, CONT INTRAOCUL LENS, V4, P74
[8]  
CHARMAN WN, 1985, OPHTHAL PHYSL OPT, V5, P211, DOI 10.1111/j.1475-1313.1985.tb00658.x
[9]   Correcting anterior corneal aberration and variability of lens movements in keratoconic eyes with back-surface customized soft contact lenses [J].
Chen, Minghan ;
Sabesan, Ramkumar ;
Ahmad, Kamran ;
Yoon, Geunyoung .
OPTICS LETTERS, 2007, 32 (21) :3203-3205
[10]   Changes of ocular higher order aberration in on- and off-eye of rigid gas permeable contact lenses [J].
Choi, Jin ;
Wee, Won Ryang ;
Lee, Jin Hak ;
Kim, Mee Kum .
OPTOMETRY AND VISION SCIENCE, 2007, 84 (01) :42-51