SURGEON PERCEPTION OF CANCELLOUS SCREW FIXATION

被引:0
|
作者
Stoesz, Michael J. [1 ]
Jastifer, James R. [1 ]
Chess, Joseph L. [1 ]
Patel, Bipin
Gustafson, Peter A.
机构
[1] Michigan State Univ, Kalamazoo Ctr Med Studies, Kalamazoo, MI 49008 USA
关键词
PULLOUT STRENGTH; CORTICAL BONE; TORQUE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ability of surgeons to optimize screw insertion torque in nonlocking fixation constructs is important for stability, particularly in osteoporotic and cancellous bone: This study evaluated screw torque applied by surgeons during simulated cancelbus fixation. It evaluated the frequency that synthetic cancellous bone were stripped by the surgeon, factors associated with bone stripping, and the ability of surgeons to recognize it.
引用
收藏
页码:1007 / 1008
页数:2
相关论文
共 50 条
  • [21] A novel parameter for the prediction of pedicle screw fixation in cancellous bone - A biomechanical study on synthetic foam
    Weidling, Martin
    Oefner, Christoph
    Schoenfelder, Stephan
    Heyde, Christoph-E
    MEDICAL ENGINEERING & PHYSICS, 2020, 79 (79) : 44 - 51
  • [22] The role of cancellous screw with tension band fixation in the treatment of displaced olecranon fractures, a comparative study
    Adel Refaat Ahmed
    Tamer Sweed
    Adel Wanas
    European Journal of Orthopaedic Surgery & Traumatology, 2008, 18
  • [23] Influence of pilot hole diameter in cancellous screw fixation in a reduced density animal bone model
    Stewart, Alexander J.
    Miles, Anthony W.
    Fletcher, James W. A.
    CLINICAL BIOMECHANICS, 2020, 80
  • [24] Screw fixation in cancellous osteoporotic bone-first in vitro results with a novel augmentation material
    Kock H.-J.
    Pokinskyj P.
    Wenz R.
    Linhart W.
    European Journal of Trauma, 2001, 27 (5): : 250 - 256
  • [25] Delayed union of a sacral fracture: Percutaneous navigated autologous cancellous bone grafting and screw fixation
    Huegli, RW
    Messmer, P
    Jacob, AL
    Regazzoni, P
    Styger, S
    Gross, T
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 26 (05) : 502 - 505
  • [26] Biomechanical comparison of the combined partially threaded cancellous lag screw and partially threaded cancellous lag screw
    Xu, Daqiang
    Sun, Peidong
    Wang, Jian
    Zhao, Weidong
    Yang, Huilin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (02): : 2574 - 2581
  • [27] A True Percutaneous Anterior Odontoid Screw Fixation: The Results of 42 Cases by a Single Surgeon
    Sucu, Hasan Kamil
    WORLD NEUROSURGERY, 2022, 166 : E892 - E904
  • [28] A True Percutaneous Anterior Odontoid Screw Fixation: The Results of 42 Cases by a Single Surgeon
    Sucu, Hasan Kamil
    WORLD NEUROSURGERY, 2022, 166 : E892 - E904
  • [29] Cancellous bone graft from the distal radius and headless screw fixation for unstable scaphoid waist nonunion
    Bae, Joo-Yul
    Choi, Shin Woo
    Lee, Wonsun
    Song, Myeong Geun
    Song, Jae-Seok
    Kim, Jae Kwang
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (02) : 487 - 493
  • [30] Cancellous bone graft from the distal radius and headless screw fixation for unstable scaphoid waist nonunion
    Joo-Yul Bae
    Shin Woo Choi
    Wonsun Lee
    Myeong Geun Song
    Jae-Seok Song
    Jae Kwang Kim
    International Orthopaedics, 2024, 48 : 487 - 493