Corrosion of orthodontic temporary anchorage devices

被引:10
作者
Knutson, Kevin J. [1 ]
Berzins, David W. [2 ]
机构
[1] Marquette Univ, Sch Dent, Dept Dev Sci Orthodont, Milwaukee, WI 53201 USA
[2] Marquette Univ, Sch Dent, Dept Gen Dent Sci Dent Biomat, Milwaukee, WI 53201 USA
关键词
COMMERCIALLY PURE TITANIUM; MINI-IMPLANTS; MINISCREW IMPLANTS; DENTAL ALLOYS; TORSIONAL PROPERTIES; ARTIFICIAL SALIVA; RESISTANCE; BEHAVIOR; FATIGUE; MOUTHWASHES;
D O I
10.1093/ejo/cjs027
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Corrosion of orthodontic miniscrews or temporary anchorage devices (TADs) has been proposed as a contributor to inflammation, which in turn is a factor in the clinical success of miniscrews. The purpose of this study was to measure the electrochemical properties of orthodontic miniscrews in artificial saliva with and without fluoride. The corrosion properties of three miniscrew products (VectorTAS, Ormco Corp.; Unitek TAD, 3M Unitek; and Through-Hole Screw, American Orthodontics) were tested in an artificial saliva (Fusayama-Meyer) with (1500 ppm) or without fluoride (n = 10/product/solution). Open circuit potential (OCP), polarization resistance (R-p), and corrosion current (I-corr) were measured and statistically analysed with the Friedman/Tukey least significant difference tests. No significant differences (P > 0.05) between miniscrews with regard to OCP, R-p, and I-corr were found except that the American Orthodontics miniscrews had a significantly (P < 0.05) more noble OCP compared to the others. Incorporation of 1500 ppm fluoride in the artificial saliva significantly (P < 0.001) lowered the OCP, reduced the polarization resistance, and increased the corrosion current of each miniscrew product. Few differences existed in the electrochemical properties of miniscrews from the three different manufacturers; however, exposure to fluoride was detrimental to the corrosion properties of all miniscrews.
引用
收藏
页码:500 / 506
页数:7
相关论文
共 46 条
  • [1] Abdolldhi Z., 2009, INT J CHEM BIOL ENG, V2, P44
  • [2] [Anonymous], UHLIGS CORROSION HDB
  • [3] Corrosion behavior of as-received and previously cast high noble alloy
    Ayad, Mohamed F.
    Vermilyea, Stanley G.
    Rosenstiel, Stephen F.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (01) : 34 - 40
  • [4] Buschang Peter H, 2008, J Clin Orthod, V42, P513
  • [5] Metal is not inert: Role of metal ions released by biocorrosion in aseptic loosening-Current concepts
    Cadosch, Dieter
    Chan, Erwin
    Gautschi, Oliver P.
    Filgueira, Luis
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 91A (04) : 1252 - 1262
  • [6] Miniscrew stability evaluated with computerized tomography scanning
    Cha, Jung-Yul
    Kil, Jae-Kyoung
    Yoon, Tae-Min
    Hwang, Chung-Ju
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (01) : 73 - 79
  • [7] The effect of topical fluorides on decalcification in patients with fixed orthodontic appliances: A systematic review
    Chadwick, BL
    Roy, J
    Knox, J
    Treasure, ET
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (05) : 601 - 606
  • [8] Fatigue and Fluoride Corrosion on Streptococcus mutans Adherence to Titanium-Based Implant/Component Surfaces
    Correa, Cassia Bellotto
    Pires, Juliana Rico
    Fernandes-Filho, Romeu Belon
    Sartori, Rafael
    Vaz, Luis Geraldo
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (05): : 382 - 387
  • [9] Cotrim-Ferreira Flávio Augusto, 2010, Braz. oral res., V24, P438
  • [10] Miniscrews in orthodontic treatment: Review and analysis of published clinical trials
    Crismani, Adriano G.
    Bertl, Michael H.
    Celar, Ales G.
    Bantleon, Hans-Peter
    Burstone, Charles J.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (01) : 108 - 113