PURPOSE: To evaluate the axis difference between corneal and internal astigmatism in patients with cataract, because if the axis of corneal astigmatism is opposite to the axis of internal astigmatism, the amount of refractive astigmatism will increase after cataract surgery owing to disappearance of the neutralizing effect of the crystalline lens on corneal astigmatism. DESIGN: Retrospective cross-sectional study. METHODS: One hundred eighty patients (180 eyes) who underwent cataract surgery were enrolled. Preoperative refractive, corneal, and internal astigmatism were measured using a wavefront analyzer and retrospectively analyzed. On-axis was defined as an axis difference between corneal and internal astigmatism of 180 10 degrees. Opposite-axis was defined as an axis difference between corneal and internal astigmatism of 90 10 degrees. The remaining cases were defined as oblique-axis. RESULTS: Corneal and internal astigmatic vectors showed a tendency to have the opposite direction. An on-axis difference was seen in 10.0% of patients (18 eyes), oblique-axis in 69.4% of patients (125 eyes), and opposite-axis in 20.6% of patients (37 eyes). Of all eyes, 10.0% had an opposite-axis difference with more than 1.00 diopter (D) of both corneal and internal astigmatism. The percentage of eyes with an opposite-axis difference between corneal and internal astigmatism had a tendency to increase as corneal and internal astigmatism increased (P = .030 and P = .003, respectively). CONCLUSIONS: A total of 10.0% of all eyes with cataract had an opposite-axis difference with more than 1.00 D of both corneal and internal astigmatism. In these cases, surgical techniques to reduce corneal astigmatism, such as a toric intraocular lens, should be recommended to increase patient satisfaction. ((C) 2013 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:1112 / 1119
页数:8
相关论文
共 22 条
[1]   Astigmatism analysis by the Alpins method [J].
Alpins, N .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01) :31-49
[2]   New method of targeting vectors to treat astigmatism [J].
Alpins, NA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (01) :65-75
[3]   Astigmatism management in cataract surgery with the AcrySof toric intraocular lens [J].
Bauer, Noel J. C. ;
de Vries, Niels E. ;
Webers, Carroll A. B. ;
Hendrikse, Fred ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1483-1488
[4]   Prevalence of corneal astigmatism before cataract surgery in Chinese patients [J].
Chen, Weirong ;
Zuo, Chengguo ;
Chen, Chuyin ;
Su, Jinai ;
Luo, Lixia ;
Congdon, Nathan ;
Liu, Yizhi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (02) :188-192
[5]  
Dunne MCM, 1996, ACTA OPHTHALMOL SCAN, V74, P14
[6]   Prevalence of corneal astigmatism before cataract surgery [J].
Ferrer-Blasco, Teresa ;
Montes-Mico, Robert ;
Peixoto-de-Matos, Sofia C. ;
Gonzalez-Meijome, Jose M. ;
Cervino, Alejandro .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) :70-75
[7]   Five-year refractive changes in an adult population - Reykjavik eye study [J].
Gudmundsdottir, E ;
Arnarsson, A ;
Jonasson, F .
OPHTHALMOLOGY, 2005, 112 (04) :672-677
[8]   Effects of Aging on Anterior and Posterior Corneal Astigmatism [J].
Ho, Jau-Der ;
Liou, Shiow-Wen ;
Tsai, Ray Jui-Fang ;
Tsai, Ching-Yao .
CORNEA, 2010, 29 (06) :632-637
[9]   Accuracy of Corneal Astigmatism Estimation by Neglecting the Posterior Corneal Surface Measurement [J].
Ho, Jau-Der ;
Tsai, Ching-Yao ;
Liou, Shiow-Wen .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (05) :788-795
[10]   BIOMETRY OF 7,500 CATARACTOUS EYES [J].
HOFFER, KJ .