Quantification of vancomycin in human serum by LC-MS/MS

被引:41
作者
Koenig, Katrin [1 ]
Kobold, Uwe [2 ]
Fink, Gerhard [2 ]
Leinenbach, Andreas [2 ]
Duelffer, Thomas [2 ]
Thiele, Roland [2 ]
Zander, Johannes [1 ]
Vogeser, Michael [1 ]
机构
[1] Hosp Univ Munich, Inst Lab Med, D-81375 Munich, Germany
[2] Roche Diagnost GmbH, Penzberg, Germany
关键词
LC-MS/MS; liquid chromatography; mass spectrometry; serum; vancomycin; TANDEM MASS-SPECTROMETRY; ANTIMICROBIALS;
D O I
10.1515/cclm-2013-0142
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The aim of our work was to develop and validate a reliable LC-MS/MS-based measurement procedure for the quantification of vancomycin in serum, to be applied in the context of efforts to standardize and harmonize therapeutic drug monitoring of this compound using routine assays. Methods: Sample preparation was based on protein precipitation followed by ultrafiltration. In order to minimize differential modulation of ionization by matrix constituents extended chromatographic separation was applied leading to a retention time of 9.8 min for the analyte. Measurement was done by HPLC-ESI-MS/MS. For internal standardization the derivative vancomycin-glycin (ISTD) prepared by chemical synthesis was used, HPLC conditions ensured coelution of ISTD with the analyte. Results: In a bi-center validation total CVs of <4% were observed for quality control material ranging from 5.3 mg/L to 79.4 mg/L; accuracy was +/- 4%. No relevant ion suppression was observed. Comparative measurement of aliquots from 70 samples at the two validation sites demonstrated close agreement. Conclusions: Employing a closely related homologue molecule for internal standardization and the use of MS/MS following highly efficient sample pre-fractionation by HPLC, the method described here can be considered to offer the highest level of analytical reliability realized so far for the quantification of vancomycin in human serum. Thus, the method is suitable to be used in a comprehensive reference measurement system for vancomycin.
引用
收藏
页码:1761 / 1769
页数:9
相关论文
共 13 条
[1]   Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[2]  
[Anonymous], GUID IND BIOAN METH
[3]   Incidence of Nephrotoxicity and Association With Vancomycin Use in Intensive Care Unit Patients With Pneumonia: Retrospective Analysis of the IMPACT-HAP Database [J].
Cano, Ennie L. ;
Haque, Nadia Z. ;
Welch, Verna L. ;
Cely, Cynthia M. ;
Peyrani, Paula ;
Scerpella, Ernesto G. ;
Ford, Kimbal D. ;
Zervos, Marcus J. ;
Ramirez, Julio A. ;
Kett, Daniel H. .
CLINICAL THERAPEUTICS, 2012, 34 (01) :149-157
[4]   Rapid bioanalysis of vancomycin in serum and urine by high-performance liquid chromatography tandem mass spectrometry using on-line sample extraction and parallel analytical columns [J].
Cass, RT ;
Villa, JS ;
Karr, DE ;
Schmidt, DE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (06) :406-412
[5]   Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3019-3030
[6]   Pharmacodynamics of vancomycin and other antimicrobials in patients with Staphylococcus aureus lower respiratory tract infections [J].
Moise-Broder, PA ;
Forrest, A ;
Birmingham, MC ;
Schentag, JJ .
CLINICAL PHARMACOKINETICS, 2004, 43 (13) :925-942
[7]   Therapeutic drug monitoring of antimicrobials [J].
Roberts, Jason A. ;
Norris, Ross ;
Paterson, David L. ;
Martin, Jennifer H. .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2012, 73 (01) :27-36
[8]  
Rybak Michael, 2009, Am J Health Syst Pharm, V66, P82, DOI [10.2146/ajhp080434, 10.1086/600877]
[9]   Highly sensitive quantification of vancomycin in plasma samples using liquid chromatography-tandem mass spectrometry and oral bioavailability in rats [J].
Shibata, N ;
Ishida, M ;
Prasad, YVR ;
Gao, WH ;
Yoshikawa, Y ;
Takada, K .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02) :211-218
[10]   Candidate Reference Measurement Procedures for Serum 25-Hydroxyvitamin D3 and 25-Hydroxyvitamin D2 by Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry [J].
Stepman, Hedwig C. M. ;
Vanderroost, An ;
Van Uytfanghe, Katleen ;
Thienpont, Linda M. .
CLINICAL CHEMISTRY, 2011, 57 (03) :441-448