An appraisal of the use of an infrared digital monitoring system for long-term measurement of heart rate in reptilian embryos

被引:16
|
作者
Sartori, Marina R. [1 ]
Taylor, Edwin W. [1 ,2 ]
Abe, Augusto S. [1 ]
Crossley, Dane A., II [3 ]
机构
[1] Univ Estadual Paulista, Inst Biociencias, Dept Zool, Rio Claro, SP, Brazil
[2] Univ Birmingham, Sch Biosci, Birmingham B15 2TT, W Midlands, England
[3] Univ N Texas, Dept Biol Sci, Dev Integrat Biol Cluster, Denton, TX 76203 USA
来源
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY | 2015年 / 188卷
基金
美国国家科学基金会; 巴西圣保罗研究基金会;
关键词
Reptiles; Embryonic development; Heart rate; Buddy (R); Infrared radiation; Temperature; INCUBATION; RESPONSES; HYPOXIA; HATCH;
D O I
10.1016/j.cbpa.2015.06.012
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of heart rate (f(H)) in embryonic reptiles has previously imposed some degree of invasive treatment on the developing embryo. Recently a non-invasive technique of f(H) detection from intact eggs was developed for commercial avian breeders and has since been used in biological research. This device uses infrared light, enabling it to detect heartbeats in very early embryos. However, infrared light is a source of heat and extended enclosure of an egg in the device is likely to affect temperature with consequent effects on physiological processes, including f(H). We studied the effect of use of the monitor on the temperature of eggs and on fH in two species of reptiles, the snapping turtle (Chelydra serpentina) and the green iguana (Iguana iguana). Egg temperature increased from a room temperature of 27-28 degrees C, by 26% in turtles and 14% in iguanas over 1 h of enclosure, resulting in an increase in f(H) of 76-81% in turtles and 35-50% iguanas. These effects on f(H) can either be avoided by brief enclosure of each egg in the monitor or measured and accounted for during the design of long-term experiments. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [21] Temperature effects on vision measurement system in long-term continuous monitoring of displacement
    Zhou, H. F.
    Zheng, J. F.
    Xie, Z. L.
    Lu, L. J.
    Ni, Y. Q.
    Ko, J. M.
    RENEWABLE ENERGY, 2017, 114 : 968 - 983
  • [22] Portable system for force measurement of long-term monitoring during human gait
    Sehnen, Romulo
    Balbinot, Amanda
    Balbinot, Alexandre
    PROCEEDINGS IWBBIO 2013: INTERNATIONAL WORK-CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, 2013, : 215 - 222
  • [23] MUSCLE FORCE MEASUREMENT SYSTEM FOR LONG-TERM MONITORING DURING DISTRACTION OSTEOGENESIS
    Jaw, Fu-Shan
    Hung, Chien-Ya
    Lin, Chia-Ming
    Lu, Pen-Li
    Tseng, Yi-Li
    Wang, Jyh-Horng
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2011, 39 (06) : 475 - 485
  • [24] Long-term Use and possible Effects of Using the mobile Motion Measurement with digital Technologies
    Schlomann, A. L.
    Seifert, A.
    ZEITSCHRIFT FUR GERONTOLOGIE UND GERIATRIE, 2018, 51 : 31 - 32
  • [25] Development of a near-infrared spectroscopic system for monitoring urine glucose level for the use of long-term home healthcare
    Tanaka, Shinobu
    Hayakawa, Yuuto
    Ogawa, Mitsuhiro
    Yamakoshi, Ken-ichi
    6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544
  • [26] Factors associated with long-term use of digital devices in the electronic Framingham Heart Study
    Pathiravasan, Chathurangi H.
    Zhang, Yuankai
    Wang, Xuzhi
    Trinquart, Ludovic
    Benjamin, Emelia J.
    Borrelli, Belinda
    McManus, David D.
    Kheterpal, Vik
    Lin, Honghuang
    Spartano, Nicole L.
    Schramm, Eric
    Liu, Chunyu
    Murabito, Joanne M.
    NPJ DIGITAL MEDICINE, 2022, 5 (01)
  • [27] Factors associated with long-term use of digital devices in the electronic Framingham Heart Study
    Chathurangi H. Pathiravasan
    Yuankai Zhang
    Xuzhi Wang
    Ludovic Trinquart
    Emelia J. Benjamin
    Belinda Borrelli
    David D. McManus
    Vik Kheterpal
    Honghuang Lin
    Nicole L. Spartano
    Eric Schramm
    Chunyu Liu
    Joanne M. Murabito
    npj Digital Medicine, 5
  • [29] Research on the Construction of a Digital Twin System for the Long-Term Service Monitoring of Port Terminals
    Bi, Jinqiang
    Wang, Peiren
    Zhang, Wenjia
    Bao, Kexin
    Qin, Liu
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2024, 12 (07)
  • [30] STUDYING LONG-TERM SYSTEM USE
    KAY, J
    THOMAS, RC
    COMMUNICATIONS OF THE ACM, 1995, 38 (07) : 61 - 69