An integrated system based on wireless sensor networks for patient monitoring, localization and tracking

被引:85
作者
Redondi, Alessandro [1 ]
Chirico, Marco
Borsani, Luca [1 ]
Cesana, Matteo
Tagliasacchi, Marco
机构
[1] Politecn Milan, Dipartimento Elettron & Informaz, Adv Network Technol Lab ANTLab, I-20133 Milan, Italy
关键词
Indoor localization; E-health; Wireless sensor network;
D O I
10.1016/j.adhoc.2012.04.006
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This works describes the system LAURA which provides patient localization, tracking and monitoring services within nursing institutes through a wireless sensor network. The system is composed of three functional blocks: a localization and tracking engine which performs localization out of samples of the received signal strength and tracking through a particle filter; a personal monitoring module based on bi-axial accelerometers which classifies the movements of the patients eventually detecting hazardous situations, and a wireless communication infrastructure to deliver the information remotely. The paper comments on the design and dimensioning of the building blocks. Two approaches are proposed to the implementation of the localization and tracking engine: a centralized implementation where localization is executed centrally out of information collected locally, and a distributed solution where the localization is performed at the mobile nodes and the outcome is delivered to the central controller. Strengths and weaknesses of the two solutions are highlighted from a system's perspective in terms of localization accuracy, energy efficiency and traffic loads. LAURA modules are finally tested in a real environment using commercial hardware. The main outcomes are an average localization error lower than 2 m in 80% of the cases and a movements classification accuracy as high as 90%. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:39 / 53
页数:15
相关论文
共 30 条
[1]   Physical activity monitoring based on accelerometry: validation and comparison with video observation [J].
Aminian, K ;
Robert, P ;
Buchser, EE ;
Rutschmann, B ;
Hayoz, D ;
Depairon, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (03) :304-308
[2]  
[Anonymous], TECHNOLOGY HLTH CARE
[3]  
[Anonymous], P 8 IEEE INT C WIR O
[4]  
[Anonymous], 5 INT C NETW SERV 20
[5]  
[Anonymous], MED BIOL ENG COMPUTI
[6]  
[Anonymous], IEEE PERVASIVE HLTH
[7]  
[Anonymous], BEHAV RES METHODS IN
[8]  
[Anonymous], IEEE INT WORKSH ADV
[9]  
[Anonymous], IEEE T INFORM TECHNO
[10]   THE FREQUENCY CONTENT OF GAIT [J].
ANTONSSON, EK ;
MANN, RW .
JOURNAL OF BIOMECHANICS, 1985, 18 (01) :39-47