Validity of a Smartphone-based instrumented Timed Up and Go

被引:107
作者
Mellone, Sabato [1 ]
Tacconi, Carlo [2 ]
Chiari, Lorenzo [1 ]
机构
[1] Univ Bologna, Dept Elect Comp Sci & Syst DEIS, Biomed Engn Unit, I-40136 Bologna, Italy
[2] Univ Bologna, Hlth Sci & Technol Interdept Ctr Ind Res, I-40136 Bologna, Italy
关键词
Timed Up and Go; Smartphone; Accelerometer; Mobile sensing; Reliability; GAIT; VARIABILITY; BALANCE;
D O I
10.1016/j.gaitpost.2012.02.006
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The Timed Up and Go (TUG) is one of the most widely used clinical tests to assess balance and mobility. An instrumented Timed Up and Go (iTUG) makes use of a specialized measurement system (e.g. an accelerometer) to identify and evaluate specific mobility skills. Nowadays a Smartphone (SP) comes with a large set of embedded sensors, including an accelerometer. An SP is a user-friendly device able to perform ubiquitous sensing with a variety of connectivity options. In this study we evaluate the validity of an SP for instrumenting the TUG. We examined 49 subjects (59 16 years old), without defining any inclusion criteria, using both an SP and a McRoberts Dynaport Hybrid, a device specifically designed for movement analysis. The statistical agreement between the two measurement systems is good for some of the parameters described in literature, which are of clear clinical value. Inter-rater reliability is often excellent and intra-rater reliability has been assessed in a subgroup of 25 subjects finding the same results for the two devices. In conclusion we found evidence that the SP is capable of becoming a pervasive and low-cost tool for the quantitative analysis of balance and mobility. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:163 / 165
页数:3
相关论文
共 15 条
[1]  
BERG KO, 1992, ARCH PHYS MED REHAB, V73, P1073
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Consolvo S, 2008, CHI 2008: 26TH ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS VOLS 1 AND 2, CONFERENCE PROCEEDINGS, P1797
[4]   Detection of gait and postures using a miniaturised triaxial accelerometer-based system: Accuracy in community-dwelling older adults [J].
Dijkstra, Baukje ;
Kamsma, Yvo ;
Zijlstra, Wiebren .
AGE AND AGEING, 2010, 39 (02) :259-262
[5]   Gait variability and fall risk in community-living older adults: A 1-year prospective study [J].
Hausdorff, JM ;
Rios, DA ;
Edelberg, HK .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (08) :1050-1056
[6]   A Survey of Mobile Phone Sensing [J].
Lane, Nicholas D. ;
Miluzzo, Emiliano ;
Lu, Hong ;
Peebles, Daniel ;
Choudhury, Tanzeem ;
Campbell, Andrew T. .
IEEE COMMUNICATIONS MAGAZINE, 2010, 48 (09) :140-150
[7]   Psychometric comparisons of the timed up and go, one-leg stand, functional reach, and Tinetti balance measures in community-dwelling older people [J].
Lin, MR ;
Hwang, HF ;
Hu, MH ;
Wu, HDI ;
Wang, YW ;
Huang, FC .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2004, 52 (08) :1343-1348
[8]   Guideline for the prevention of falls in older persons [J].
Lundebjerg, N ;
Rubenstein, LZ ;
Kenny, RA ;
Koval, KJ ;
Martin, FC ;
Tinetti, ME ;
Apple, DF ;
Cantrill, JA ;
Chang, JT ;
Duncan, PW ;
Ellis, M ;
Hogan, T ;
Lipsitz, LA ;
Rich, MW ;
Strumpf, NE ;
Wallace, WA ;
Young, A .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2001, 49 (05) :664-672
[9]  
Marschollek M, 2009, Z GERONTOL GERIATR, V42, P317, DOI 10.1007/s00391-009-0035-7
[10]   Interstride trunk acceleration variability but not step width variability can differentiate between fit and frail older adults [J].
Moe-Nilssen, R ;
Helbostad, JL .
GAIT & POSTURE, 2005, 21 (02) :164-170