Quantification of typical antipsychotics in human plasma by ultra-high performance liquid chromatography tandem mass spectrometry for therapeutic drug monitoring

被引:32
|
作者
Gradinaru, Julieta [1 ]
Vullioud, Astrid [1 ]
Eap, Chin B. [1 ,2 ]
Ansermot, Nicolas [1 ]
机构
[1] Univ Lausanne Hosp, Hosp Cery, Ctr Psychiat Neurosci,Dept Psychiat, Unit Pharmacogenet & Clin Psychopharmacol, CH-1008 Prilly, Switzerland
[2] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, Geneva, Switzerland
关键词
Antipsychotics; Protein precipitation; UHPLC-MS/MS; Method validation; Therapeutic drug monitoring; SOLID-PHASE EXTRACTION; ELECTROSPRAY-IONIZATION; GAS-CHROMATOGRAPHY; HUMAN SERUM; QUANTITATIVE-DETERMINATION; CHEMICAL-IONIZATION; PSYCHOTROPIC-DRUGS; HALOPERIDOL; METABOLITES; ZUCLOPENTHIXOL;
D O I
10.1016/j.jpba.2013.07.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective and sensitive method was developed for the simultaneous quantification of seven typical antipsychotic drugs (cis-chlorprothixene, flupentixol, haloperidol, levomepromazine, pipamperone, promazine and zuclopenthixol) in human plasma. Ultra-high performance liquid chromatography (UHPLC) was used for complete separation of the compounds in less than 4.5 min on an Acquity UPLC BEH C18 column (2.1 mm x 50 mm; 1.7 mu m) with a gradient elution of ammonium formate buffer pH 4.0 and acetonitrile at a flow rate of 400 mu l/min. Detection was performed on a tandem quadrupole mass spectrometer (MS/MS) equipped with an electrospray ionization interface. A simple protein precipitation procedure with acetonitrile was used for sample preparation. Thanks to the use of stable isotope-labeled internal standards for all analytes, internal standard-normalized matrix effects were in the range of 92-108%. The method was fully validated to cover large concentration ranges of 0.2-90 ng/ml for haloperidol, 0.5-90 ng/ml for flupentixol, 1-450 ng/ml for levomepromazine, promazine and zuclopenthixol and 2-900 ng/ml for cis-chlorprothixene and pipamperone. Trueness (89.1-114.8%), repeatability (1.8-9.9%), intermediate precision (1.9-16.3%) and accuracy profiles (<30%) were in accordance with the latest international recommendations. The method was successfully used in our laboratory for routine quantification of more than 500 patient plasma samples for therapeutic drug monitoring. To the best of our knowledge, this is the first UHPLC-MS/MS method for the quantification of the studied drugs with a sample preparation based on protein precipitation. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 44
页数:9
相关论文
共 50 条
  • [41] Optimized ultra performance liquid chromatography tandem high resolution mass spectrometry method for the quantification of paraquat in plasma and urine
    Lu, Haihua
    Yu, Jing
    Wu, Linlin
    Xing, Jingjing
    Wang, Jun
    Huang, Peipei
    Zhang, Jinsong
    Xiao, Hang
    Gao, Rong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1027 : 96 - 102
  • [42] ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY WITH ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMETRY FOR THE DETERMINATION OF CAFFEINE IN ENERGY DRINKS
    Lee, Min Soo
    Nguyen Lan Huong
    Nguyen Huu Hoang
    Shrestha, Anil
    Park, Je Won
    ANALYTICAL LETTERS, 2014, 47 (11) : 1852 - 1861
  • [43] Analysis of perfluorinated chemicals in umbilical cord blood by ultra-high performance liquid chromatography/tandem mass spectrometry
    Lien, Guang-Wen
    Wen, Ting-Wen
    Hsieh, Wu-Shiun
    Wu, Kuen-Yuh
    Chen, Chia-Yang
    Chen, Pau-Chung
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (9-10): : 641 - 646
  • [44] Dried plasma spot-based liquid chromatography-tandem mass spectrometry for the quantification of methotrexate in human plasma and its application in therapeutic drug monitoring
    Cao, Haiwei
    Li, Li
    Wang, Shaomin
    Guo, Haiyang
    Ren, Wenbo
    Li, Yanyan
    Huang, Jing
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (06) : 1153 - 1161
  • [45] Quantification of a novel natural antioxidant (UP302) in rat plasma using ultra-high performance liquid chromatography-tandem mass spectrometry
    Zhang, Shuang-Qing
    Zhu, Ling
    Wen, Nie
    Yu, Min
    Shen, Yi-Zheng
    Jia, Qi
    Li, Zuo-Gang
    Li, Bo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (31): : 3763 - 3766
  • [46] Therapeutic drug monitoring of topiramate by liquid chromatography-tandem mass spectrometry
    Matar, Kamal M.
    CLINICA CHIMICA ACTA, 2010, 411 (9-10) : 729 - 734
  • [47] A simple and efficient method for imidazolinone herbicides determination in soil by ultra-high performance liquid chromatography-tandem mass spectrometry
    Kemmerich, Magali
    Bernardi, Gabrieli
    Adaime, Martha B.
    Zanella, Renato
    Prestes, Osmar D.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1412 : 82 - 89
  • [48] Ultra performance liquid chromatography-tandem mass spectrometry for the determination of epirubicin in human plasma
    Li, RP
    Dong, LL
    Huang, JX
    ANALYTICA CHIMICA ACTA, 2005, 546 (02) : 167 - 173
  • [49] Detection of 22 antiepileptic drugs by ultra-performance liquid chromatography coupled with tandem mass spectrometry applicable to routine therapeutic drug monitoring
    Shibata, Mai
    Hashi, Sachiyo
    Nakanishi, Haruka
    Masuda, Satohiro
    Katsura, Toshiya
    Yano, Ikuko
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (12) : 1519 - 1528
  • [50] Quantification of mycophenolic acid in human plasma by liquid chromatography with time-of-flight mass spectrometry for therapeutic drug monitoring
    Antunes, Natalicia J.
    Ince, Nina
    Raymond, Jason
    Kipper, Karin
    Couchman, Lewis
    Holt, David W.
    De Nucci, Gilberto
    Johnston, Atholl
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (03)