Isolated revision of an acetabular component to a ceramic-on-ceramic bearing in patients under 50 years of age

被引:16
作者
Kim, Y-H. [1 ]
Park, J-W. [2 ]
Kim, J-S. [2 ]
机构
[1] Ewha Womans Univ, Ctr Joint Replacement, MokDong Hosp, Seoul 158710, South Korea
[2] Ewha Womans Univ, Ctr Joint Replacement, Sch Med, Seoul 158710, South Korea
关键词
TOTAL HIP-ARTHROPLASTY; FOLLOW-UP; REPLACEMENT; HEAD; DISLOCATION; OSTEOLYSIS; ARTHRITIS; IMPLANTS; INGROWTH; OUTCOMES;
D O I
10.1302/0301-620X.97B9.35748
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A number of studies have reported satisfactory results from the isolated revision of an acetabular component. However, many of these studies reported only the short-to intermediate-term results of heterogeneous bearing surfaces in a mixed age group. We present our experience of using a ceramic-on-ceramic (CoC) bearing for isolated revision of an uncemented acetabular component in 166 patients (187 hips) who were under the age of 50 years at the time of revision. There were 78 men and 88 women with a mean age of 47.4 years (28 to 49). The most common reason for revision was polyethylene wear and acetabular osteolysis in 123 hips (66%), followed by aseptic loosening in 49 hips (26%). We report the clinical and radiological outcome, complication rate, and survivorship of this group. The mean duration of follow-up was 15.6 years (11 to 19). The mean pre-operative Harris hip score was 33 points (1 to 58), and improved to a mean of 88 points (51 to 100) at follow-up. The mean pre-operative total Western Ontario and McMaster Universities Osteoarthritis Index score was 63.2 (43 to 91) and improved to 19.8 points (9 to 61) post-operatively. Overall, 153 of 166 patients (92%) were satisfied with their outcome. Kaplan-Meier survivorship analysis, with revision or radiological evidence of implant failure (13 patients, 8%) as end-points, was 92% at 15 years (95% confidence interval 0.89 to 0.97). Isolated revision of a cementless acetabular component using a CoC bearing gives good results in patients under 50 years of age.
引用
收藏
页码:1197 / 1203
页数:7
相关论文
共 35 条
[1]  
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, P7
[2]   Reproducible assessment of radiolucent lines in total knee arthroplasty [J].
Bach, CM ;
Biedermann, R ;
Goebel, G ;
Mayer, E ;
Rachbauer, F .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (434) :183-188
[3]   Revision total hip arthroplasty - The patient's perspective [J].
Barrack, Robert L. ;
McClure, J. Thomas ;
Burak, Corey F. ;
Clohisy, John C. ;
Parvizi, Javad ;
Hozack, William .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) :173-177
[4]  
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[5]   Revision of an acetabular liner has a high risk of dislocation [J].
Blom, AW ;
Astle, L ;
Loveridge, J ;
Learmonth, ID .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (12) :1636-1638
[6]   Isolated acetabular revision after total hip arthroplasty: results at 5-9 years of follow-up [J].
Chen, XD ;
Waddell, JP ;
Morton, J ;
Schemitsch, EH .
INTERNATIONAL ORTHOPAEDICS, 2005, 29 (05) :277-280
[7]   A Dual-mobility Cup Reduces Risk of Dislocation in Isolated Acetabular Revisions [J].
Civinini, Roberto ;
Carulli, Christian ;
Matassi, Fabrizio ;
Nistri, Lorenzo ;
Innocenti, Massimo .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (12) :3542-3548
[8]  
CLARKE IC, 1992, CLIN ORTHOP RELAT R, P19
[9]   Reasons for revision hip surgery - A retrospective review [J].
Clohisy, JC ;
Calvert, G ;
Tull, F ;
McDonald, D ;
Maloney, WJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :188-192
[10]   Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 Years [J].
D'Antonio, James A. ;
Capello, William N. ;
Naughton, Marybeth .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) :373-381