A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole

被引:19
作者
Abbas, Mohammad Nooredeen [1 ]
Amer, Hend Samy [1 ]
机构
[1] Natl Res Ctr, Appl Organ Chem Dept, Analyt Lab, Cairo, Egypt
关键词
Indium(III); Solid-contact sensor; Thiosulfinate; Omeprazole dimer; FIA; ION-SELECTIVE ELECTRODES; STABILITY; POLY(3,4-ETHYLENEDIOXYTHIOPHENE); COEFFICIENTS; VALUES; ACID;
D O I
10.5012/bkcs.2013.34.4.1153
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel solid-contact indium(III)-selective sensor based on bis-(1H-benzimidazole-5-methoxy-2[(4-methoxy-3, 5-dimethyl-1-pyridinyl) 2-methyl]) thiosulfinate, known as an omeprazole dimer (OD) and a neutral ionophore, was constructed, and its performance characteristics were evaluated. The sensor was prepared by applying a membrane cocktail containing the ionophore to a graphite rod pre-coated with polyethylene dioxythiophene (PEDOT) conducting polymer as the ion-to-electron transducer. The membrane contained 3.6% OD; 2.3% oleic acid (OA) and 62% dioctyl phthalate (DOP) as the solvent mediator in PVC and produced a good potentiometric response to indium(III) ions with a Nernstian slope of 19.09 mV/decade. The constructed sensor possessed a linear concentration range from 3 x 10(-7) to 1 x 10(-2) M and a lower detection limit (LDL) of 1 x 10(-7) M indium(III) over a pH range of 4.0-7.0. It also displayed a fast response time and good selectivity for indium(III) over several other ions. The sensor can be used for longer than three months without any considerable divergence in potential. The sensor was utilized for direct and flow injection potentiometric (FIP) determination of indium(III) in alloys. The parameters that control the flow injection method were optimized. Indium(III) was quantitatively recovered, and the results agreed with those obtained using atomic absorption spectrophotometry, as confirmed by the f and t values. The sensor was also utilized as an indicator electrode for the potentiometric titration of fluoride in the presence of chloride, bromide, iodide and thiocyanate ions using indium(III) nitrate as the titrant.
引用
收藏
页码:1153 / 1159
页数:7
相关论文
共 31 条
[1]  
Abbas M. N., 2011, AM J ANAL CHEM, V2, P739
[2]  
Abdulla NI, 2005, TURK J CHEM, V29, P687
[3]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[4]   LIPOPHILICITY OF TETRAPHENYLBORATE DERIVATIVES AS ANIONIC SITES IN NEUTRAL CARRIER-BASED SOLVENT POLYMERIC MEMBRANES AND LIFETIME OF CORRESPONDING ION-SELECTIVE ELECTROCHEMICAL AND OPTICAL SENSORS [J].
BAKKER, E ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) :7-17
[5]   Nanoscale potentiometry [J].
Bakker, Eric ;
Pretsch, Ernoe .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (07) :612-618
[6]  
Benkeblia N., 2007, GLOBAL SCI BOOKS, V1, P193
[7]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[8]   A study on the utility of bismuth-film electrodes for the determination of In(III) in the presence of Pb(II) and Cd(II) by square wave anodic stripping voltammetry [J].
Charalambous, A ;
Economou, A .
ANALYTICA CHIMICA ACTA, 2005, 547 (01) :53-58
[9]   CHEMICALLY-MODIFIED FIELD-EFFECT TRANSISTORS - THE EFFECT OF ION-PAIR ASSOCIATION ON THE MEMBRANE-POTENTIALS [J].
COBBEN, PLHM ;
EGBERINK, RJM ;
BOMER, JG ;
BERGVELD, P ;
REINHOUDT, DN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 368 (1-2) :193-208
[10]  
CUNXIONG L, 1997, TALANTA, V44, P729