Experimental validation of the six-port design for a highly uniform integrating sphere photometer

被引:5
作者
Park, Seongchong [1 ]
Lee, Dong-Hoon [1 ]
Park, Seung-Nam [1 ]
Park, Chul-Woung [1 ]
机构
[1] Korea Res Inst Stand & Sci, Div Phys Metrol, Taejon 305340, South Korea
关键词
REALIZATION; SCANNER;
D O I
10.1364/AO.52.007178
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present experimental realization and validation of the six-port design of integrating sphere photometers for total luminous flux measurement, which significantly improves the uniformity of spatial response compared to the conventional single-port design. Construction, measurement procedure, and data acquisition of the realized instrument with a radius of 1 m are described. Measurement of the spatial response distribution function confirms the expected effect of improving the uniformity by averaging the signals from the six detection ports. The related spatial mismatch error is determined to be less than 1.4% for all the realistic cases of beam angles and directions of a test lamp mounted in the vicinity of the sphere center. As a result, we confirm that the realized six-port instrument allows us to eliminate the complicated spatial mismatch correction procedure by adding a relative standard uncertainty of only 1.4/root 3%0 approximate to 0.81%, which offers a great practical benefit for testing solid-state lighting products of various beam characteristics. (c) 2013 Optical Society of America
引用
收藏
页码:7178 / 7185
页数:8
相关论文
共 8 条
[1]  
Commision Internationale de l'Eclairage, 1989, 0841989 CIE
[2]   Realization and validation of the detector-based absolute integrating sphere method for luminous-flux measurement at KRISS [J].
Kim, Yong-Wan ;
Lee, Dong-Hoon ;
Park, Seung-Nam ;
Jeon, Min-Yong ;
Park, Seongchong .
METROLOGIA, 2012, 49 (03) :273-282
[3]   Realization of the luminous-flux unit using an LED scanner for the absolute integrating-sphere method [J].
Lahti, K ;
Hovila, J ;
Toivanen, P ;
Vahala, E ;
Tittonen, I ;
Ikonen, E .
METROLOGIA, 2000, 37 (05) :595-598
[4]   Detector-based luminous-flux calibration using the Absolute Integrating-Sphere Method [J].
Ohno, Y .
METROLOGIA, 1998, 35 (04) :473-478
[5]   INTEGRATING SPHERE SIMULATION - APPLICATION TO TOTAL FLUX SCALE REALIZATION [J].
OHNO, Y .
APPLIED OPTICS, 1994, 33 (13) :2637-2647
[6]  
OHNO Y, 1998, HDB APPL PHOTOMETRY, P159
[7]   Six-port integrating sphere photometer with uniform spatial response [J].
Park, Seongchong ;
Lee, Dong-Hoon ;
Park, Seung-Nam .
APPLIED OPTICS, 2011, 50 (15) :2220-2227
[8]   Convenient integrating sphere scanner for accurate luminous flux measurements [J].
Winter, S. ;
Lindemann, M. ;
Jordan, W. ;
Binder, U. ;
Anokhin, M. .
METROLOGIA, 2009, 46 (04) :S248-S251