Design evaluation of Earth-Air Heat Exchangers with multiple ducts

被引:40
|
作者
Brum, Ruth S. [1 ]
Ramalho, Jairo V. A. [1 ]
Rodrigues, Michel K. [2 ]
Rocha, Luiz A. O. [3 ]
Isoldi, Liercio A. [2 ]
Dos Santos, Elizaldo D. [2 ]
机构
[1] Univ Fed Pelotas UFPel, Inst Fis & Matemat, Campus Capao Leao S-N, BR-96160000 Pelotas, RS, Brazil
[2] Univ Fed Rio Grande, Programa Posgrad Modelagem Computac, Ave Italia,Km 8, BR-96203900 Rio Grande, RS, Brazil
[3] Univ Vale Rio Sinos UNISINOS, Programa Posgrad Engn Mecan, Ave Unisinos 950, BR-93022750 Sao Leopoldo, RS, Brazil
关键词
Earth-Air Heat Exchangers (EAHE); Constructal design; Performance; Sustainability; Numerical approach; CONSTRUCTAL DESIGN; PERFORMANCE ANALYSIS; PREDICT; SOIL;
D O I
10.1016/j.renene.2018.09.063
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Earth-Air Heat Exchangers (EAHE) are devices used to improve the thermal conditions inside built environments, which work by pumping the air through buried ducts to use the soil as heat source or sink. They explore the phase difference between the air and the ground temperatures, turning possible to heat the air in the winter or cool it in the summer. By means of Constructal Design strategies, this paper investigates geometrical configurations to assemble the ducts aiming to improve the thermal performance of their installations. This is done here by performing various computational simulations with different layouts to arrange up to five ducts, after imposing restrictions to the air flow and the installation volumes. The results show that significant improvements in EAHE efficiency can be obtained as follows: properly increasing the number of ducts and reducing their diameters, reducing, to some extent, the ratio between their vertical and horizontal spacing, and increasing the ratio between the installation volume and the computational domain. Therefore, the simple addition of ducts in EAHE installations does not mean a superior performance when no attention is paid towards how to arrange them. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1371 / 1385
页数:15
相关论文
共 50 条
  • [41] A parametric analysis of the cooling performance of vertical earth-air heat exchanger in a subtropical climate
    Ahmed, S. F.
    Khan, M. M. K.
    Amanullah, M. T. O.
    Rasul, M. G.
    Hassan, N. M. S.
    RENEWABLE ENERGY, 2021, 172 : 350 - 367
  • [42] Geo-climatic applicability of earth-to-air heat exchangers in North America
    Chiesa, Giacomo
    Zajch, Andrew
    ENERGY AND BUILDINGS, 2019, 202
  • [43] Experimental Investigation of Flow Uniformity in a Bank-Type Earth-Air Heat Exchanger
    Goyal, Vaishali
    Asati, Arun Kumar
    Arora, Amit
    CHEMICAL ENGINEERING & TECHNOLOGY, 2023, 46 (08) : 1596 - 1604
  • [44] Advances in standalone and hybrid earth-air heat exchanger (EAHE) systems for buildings: A review
    Soares, N.
    Rosa, N.
    Monteiro, H.
    Costa, J. J.
    ENERGY AND BUILDINGS, 2021, 253
  • [45] Feasibility study on applications of an Earth-air Heat Exchanger (EAHE) for preheating fresh air in severe cold regions
    Li, Hui
    Ni, Long
    Liu, Guang
    Zhao, Zisang
    Yao, Yang
    RENEWABLE ENERGY, 2019, 133 : 1268 - 1284
  • [46] Freshwater production by combination of solar still, earth-air heat exchanger and solar chimney for natural air draft
    Hammadi, Salman H.
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENGINEERING, 2021, 14 (05) : 921 - 932
  • [47] Experimental study on the characteristics of radiation floor cooling system based on an earth-air heat exchanger
    Yang, Jiaming
    Song, Wei
    Zhang, Houan
    Wang, Jing
    Dong, Jiankai
    ENERGY AND BUILDINGS, 2023, 296
  • [48] Enhancing the performance of earth-air heat exchanger: A flexible multi-objective optimization framework
    Yue, Yingjun
    Yan, Zengfeng
    Ni, Pingan
    Lei, Fuming
    Qin, Guojin
    APPLIED THERMAL ENGINEERING, 2024, 244
  • [49] Field experiments on the cooling capability of earth-to-air heat exchangers in hot and humid climate
    Wei, Haibin
    Yang, Dong
    Wang, Jilibo
    Du, Jinhui
    APPLIED ENERGY, 2020, 276
  • [50] The in-situ experiment of earth-air heat exchanger for a cafeteria building in subtropical monsoon climate
    Hsu, Chien-Yeh
    Huang, Po-Chun
    Liang, Jyun-De
    Chiang, Yuan-Ching
    Chen, Sih-Li
    RENEWABLE ENERGY, 2020, 157 : 741 - 753