Design evaluation of Earth-Air Heat Exchangers with multiple ducts

被引:40
|
作者
Brum, Ruth S. [1 ]
Ramalho, Jairo V. A. [1 ]
Rodrigues, Michel K. [2 ]
Rocha, Luiz A. O. [3 ]
Isoldi, Liercio A. [2 ]
Dos Santos, Elizaldo D. [2 ]
机构
[1] Univ Fed Pelotas UFPel, Inst Fis & Matemat, Campus Capao Leao S-N, BR-96160000 Pelotas, RS, Brazil
[2] Univ Fed Rio Grande, Programa Posgrad Modelagem Computac, Ave Italia,Km 8, BR-96203900 Rio Grande, RS, Brazil
[3] Univ Vale Rio Sinos UNISINOS, Programa Posgrad Engn Mecan, Ave Unisinos 950, BR-93022750 Sao Leopoldo, RS, Brazil
关键词
Earth-Air Heat Exchangers (EAHE); Constructal design; Performance; Sustainability; Numerical approach; CONSTRUCTAL DESIGN; PERFORMANCE ANALYSIS; PREDICT; SOIL;
D O I
10.1016/j.renene.2018.09.063
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Earth-Air Heat Exchangers (EAHE) are devices used to improve the thermal conditions inside built environments, which work by pumping the air through buried ducts to use the soil as heat source or sink. They explore the phase difference between the air and the ground temperatures, turning possible to heat the air in the winter or cool it in the summer. By means of Constructal Design strategies, this paper investigates geometrical configurations to assemble the ducts aiming to improve the thermal performance of their installations. This is done here by performing various computational simulations with different layouts to arrange up to five ducts, after imposing restrictions to the air flow and the installation volumes. The results show that significant improvements in EAHE efficiency can be obtained as follows: properly increasing the number of ducts and reducing their diameters, reducing, to some extent, the ratio between their vertical and horizontal spacing, and increasing the ratio between the installation volume and the computational domain. Therefore, the simple addition of ducts in EAHE installations does not mean a superior performance when no attention is paid towards how to arrange them. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1371 / 1385
页数:15
相关论文
共 50 条
  • [1] An experimental study on the use of Earth-Air Heat Exchangers (EAHE)
    Vaz, Joaquim
    Sattler, Miguel A.
    Brum, Ruth da S.
    dos Santos, Elizaldo D.
    Isoldi, Liercio A.
    ENERGY AND BUILDINGS, 2014, 72 : 122 - 131
  • [2] Numerical-analytical study of earth-air heat exchangers with complex geometries guided by constructal design
    Nunes, Bruna Rodrigues
    Rodrigues, Michel Kepes
    Oliveira Rocha, Luiz Alberto
    Labat, Matthieu
    Lorente, Sylvie
    dos Santos, Elizaldo Domingues
    Isoldi, Liercio Andre
    Biserni, Cesare
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (15) : 20970 - 20987
  • [3] Fitting new constructal models for the thermal potential of earth-air heat exchangers
    de Alencar Ramalho, Jairo Valoes
    Brum, Ruth da Silva
    Oliveira Rocha, Luiz Alberto
    Isoldi, Liercio Andre
    dos Santos, Elizaldo Domingues
    Sulzbacher, Mariane
    ACTA SCIENTIARUM-TECHNOLOGY, 2018, 40
  • [4] Parametric optimization of earth-air heat exchangers (EAHEs) for central air conditioning
    Hegazi, A. . A. .
    Abdelrehim, O.
    Khater, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 129 (129) : 278 - 289
  • [5] A new computational modeling to predict the behavior of Earth-Air Heat Exchangers
    Brum, Ruth da Silva
    Vaz, Joaquim
    Oliveira Rocha, Luiz Alberto
    dos Santos, Elizaldo Domingues
    Isoldi, Liercio Andre
    ENERGY AND BUILDINGS, 2013, 64 : 395 - 402
  • [6] Further realistic annual simulations of earth-air heat exchangers installations in a coastal city
    Hermes, V. F.
    Ramalho, J. V. A.
    Rocha, L. A. O.
    dos Santos, E. D.
    Marques, W. C.
    Costi, J.
    Rodrigues, M. K.
    Isoldi, L. A.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 37 (37)
  • [7] Thermal resistance capacity model for transient simulation of Earth-Air Heat Exchangers
    Minaei, Asgar
    Talee, Zahra
    Safikhani, Hamed
    Ghaebi, Hadi
    RENEWABLE ENERGY, 2021, 167 : 558 - 567
  • [8] Accessing the thermal performance of Earth-air heat exchangers surrounded by galvanized structures
    Ramalho, J. V. A.
    Fernando, H. J.
    Brum, R. S.
    Domingues, A. M. B.
    Navarro Pastor, N. R.
    Burlon Olivera, M. R.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 54
  • [9] A numerical study on cooling performance of different type earth-air heat exchangers
    Tasdelen, Fatih
    Dagtekin, Ihsan
    RENEWABLE ENERGY, 2025, 241
  • [10] The impact of latent heat exchanges on the design of earth air heat exchangers
    Estrada, Emanuel
    Labat, Matthieu
    Lorente, Sylvie
    Rocha, Luiz A. O.
    APPLIED THERMAL ENGINEERING, 2018, 129 : 306 - 317