Effects of pneumoperitoneum and Trendelenburg position on intracranial pressure assessed using different non-invasive methods

被引:81
|
作者
Robba, C. [1 ,6 ]
Cardim, D. [2 ]
Donnelly, J. [2 ]
Bertuccio, A. [3 ]
Bacigaluppi, S. [4 ]
Bragazzi, N. [5 ]
Cabella, B. [2 ]
Liu, X. [2 ]
Matta, B. [1 ]
Lattuada, M. [6 ]
Czosnyka, M. [2 ]
机构
[1] Addenbrookes Hosp, Neurosci Crit Care Unit, Box 1,Hills Rd, Cambridge CB2 0QQ, England
[2] Univ Cambridge, Addenbrookes Hosp, Dept Clin Neurosci, Brain Phys Lab,Div Neurosurg, Hills Rd, Cambridge CB2 0QQ, England
[3] Univ London, St Georges Hosp, Dept Clin Neurosci, Div Neurosurg, London, England
[4] Univ Genoa, Galliera Hosp, Dept Neurosurg, Mura Cappuccine 16, I-16100 Genoa, Italy
[5] Univ Genoa, Sch Publ Hlth, Dept Hlth Sci DISSAL, Via Antonio Pastore 1, I-16132 Genoa, Italy
[6] Galliera Hosp, Dept Anaesthesiol, Mura Cappuccine 16, I-16100 Genoa, Italy
关键词
head-down tilt; intracranial pressure; optic nerve sheath diameter; pneumoperitoneum; transcranial Doppler; NERVE SHEATH DIAMETER; OPTIC-NERVE; PULSATILITY INDEX; RADICAL PROSTATECTOMY; ULTRASONOGRAPHY; SURGERY; ASSOCIATION; SONOGRAPHY;
D O I
10.1093/bja/aew356
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The laparoscopic approach is becoming increasingly frequent for many different surgical procedures. However, the combination of pneumoperitoneum and Trendelenburg positioning associated with this approach may increase the patient's risk for elevated intracranial pressure (ICP). Given that the gold standard for the measurement of ICP is invasive, little is known about the effect of these common procedures on ICP. Methods. We prospectively studied 40 patients without any history of cerebral disease who were undergoing laparoscopic procedures. Three different methods were used for non-invasive estimation of ICP: ultrasonography of the optic nerve sheath diameter (ONSD); transcranial Doppler-based (TCD) pulsatility index (ICPN); and a method based on the diastolic component of the TCD cerebral blood flow velocity (ICPrvd). The ONSD and TCD were measured immediately after induction of general anaesthesia, after pneumoperitoneum insufflation, after Trendelenburg positioning, and again at the end of the procedure. Results, The ONSD, ICPrvd, and ICPp1 increased significantly after the combination of pneumoperitoneum insufflation and Trendelenburg positioning. The ICPrvd showed an area under the curve of 0.80 [95% confidence interval (CI) 0.70-0.90] to distinguish the stage associated with the application of pneumoperitoneum and Trendelenburg position; ONSD and ICPN showed an area under the curve of 0.75 (95% CI 0.65-0.86) and 0.70 (95% CI 0.58-0.81), respectively. Conclusions. The concomitance of pneumoperitoneum and the Trendelenburg position can increase ICP as estimated with non-invasive methods. In high-risk patients undergoing laparoscopic procedures, non-invasive ICP monitoring through a combination of ONSD ultrasonography and TCD-derived ICPrvd could be a valid option to assess the risk of increased ICP.
引用
收藏
页码:783 / 791
页数:9
相关论文
共 50 条
  • [21] Ultrasound non-invasive intracranial pressure assessment in paediatric neurocritical care: a pilot study
    Chiara Robba
    Danilo Cardim
    Marek Czosnyka
    Francisco Abecasis
    Stefano Pezzato
    Silvia Buratti
    Andrea Moscatelli
    Cristina Sortica
    Fabrizio Racca
    Paolo Pelosi
    Frank Rasulo
    Child's Nervous System, 2020, 36 : 117 - 124
  • [22] New non-invasive sonographic modality for intracranial pressure/volume monitoring
    Fountas K.N.
    Sitkauskas A.
    Troup E.C.
    Feltes C.H.
    Dimopoulos V.
    Deltuva V.
    Daubaris G.
    Ragauskas A.
    Robinson Jr. J.S.
    Child’s Nervous System, 2002, 18 (5) : 211 - 214
  • [23] Non-invasive Estimation of Intracranial Pressure by Means of Retinal Venous Pulsatility
    Golzan, S. Mojtaba
    Graham, Stuart L.
    Avolio, Alberto
    26TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE: SBEC 2010, 2010, 32 : 81 - 84
  • [24] Review of non-invasive intracranial pressure measurement techniques for ophthalmology applications
    Price, David Andrew
    Grzybowski, Andrzej
    Eikenberry, Jennifer
    Januleviciene, Ingrida
    Verticchio Vercellin, Alice Chandra
    Mathew, Sunu
    Siesky, Brent
    Harris, Alon
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (07) : 887 - 892
  • [25] Evoked potentials - non-invasive indicators for intracranial pressure
    Engelhardt, W
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1997, 32 (02): : S250 - +
  • [26] An Ultrasonic Transceiver for Non-Invasive Intracranial Pressure Sensing
    Topalli, Gerald
    Fan, Yingying
    Cheung, Matt Y.
    Veeraraghavan, Ashok
    Hirzallah, Mohammad
    Chi, Taiyun
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2024, 18 (06) : 1220 - 1232
  • [27] Transcranial doppler in the non-invasive estimation of intracranial pressure in traumatic brain injury compared to other non-invasive methods in lower-middle income countries: Systematic review and meta-analysis
    Dokponou, Yao Christian Hugues
    Badirou, Omar Boladji Adebayo
    Agada, Kpegnon Nicaise
    Dossou, Mehome Wilfried
    Lawson, Late Dzidoula
    Ossaga, Madjoue Arsene Desire
    Nyalundja, Arsene Daniel
    Adjiou, Dognon Kossi Francois de Paule
    Lassissi, Katib Ulrich
    Houndodjade, Sena Midas Credo
    Gbenou, Ferol Baudelaire Babatunde
    Lantonkpode, Romaric Paterne
    Togbenon, Nukunte David Lionel
    Bankole, Nourou Dine Adeniran
    JOURNAL OF CLINICAL NEUROSCIENCE, 2023, 113 : 70 - 76
  • [28] Non-invasive intracranial pressure assessment using shear-wave elastography in neuro-critical care patients
    Xu, Guohui
    Wu, Xuehai
    Yu, Jian
    Ding, Hong
    Ni, Zilong
    Wang, Yong
    JOURNAL OF CLINICAL NEUROSCIENCE, 2022, 99 : 261 - 267
  • [29] Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?
    Danilo Cardim
    C. Robba
    M. Bohdanowicz
    J. Donnelly
    B. Cabella
    X. Liu
    M. Cabeleira
    P. Smielewski
    B. Schmidt
    M. Czosnyka
    Neurocritical Care, 2016, 25 : 473 - 491
  • [30] Analysis of intracranial pressure waveform using a non-invasive method in individuals with craniosynostosis
    Brandao, Michele Madeira
    Tonello, Cristiano
    Parizotto, Isabella
    Machado, Luciano Brandao
    Alonso, Nivaldo
    CHILDS NERVOUS SYSTEM, 2024, 40 (01) : 145 - 152