摘要
A sensitive magnetic resonance imaging (MRI) method to measure spinal cord cross-sectional area with the potential to monitor disease progression has recently been developed, As changes in cord area due to disease are usually small, assessment of the reliability of the methodology is essential in serial studies of spinal cord atrophy. The aim of this study was to institute and evaluate a protocol of quality assurance to determine long-term reproducibility of serial studies, Serial MRI of the spinal cord was carried out in five healthy volunteer controls over 1 year, Cross-sectional spinal cord areas were measured in a total of 46 scans, The mean coefficient of variation of all subjects over one year was 1.35%. The intra-observer coefficient of variation for same scan analysis was 0.63%. This study has confirmed high reliability of our serial data over one year and the on-going quality assurance protocol enables continuing evaluation of the reproducibility of results in serial studies, Quality assurance is an essential and practical component of all serial MRI studies, without which the clinical implications of change cannot be reliably evaluated. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:773 / 776
页数:4
相关论文
共 10 条
  • [1] A spinal cord MRI study of benign and secondary progressive multiple sclerosis
    Filippi, M
    Campi, A
    Colombo, B
    Pereira, C
    Martinelli, V
    Baratti, C
    Comi, G
    [J]. JOURNAL OF NEUROLOGY, 1996, 243 (07) : 502 - 505
  • [2] Evaluating neurological outcome measures: The bare essentials
    Hobart, JC
    Lamping, DL
    Thompson, AJ
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1996, 60 (02) : 127 - 130
  • [3] MRI dynamics of brain and spinal cord in progressive multiple sclerosis
    Kidd, D
    Thorpe, JW
    Kendall, BE
    Barker, GJ
    Miller, DH
    McDonald, WI
    Thompson, AJ
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1996, 60 (01) : 15 - 19
  • [4] SPINAL-CORD MRI USING MULTIARRAY COILS AND FAST SPIN-ECHO .2. FINDINGS IN MULTIPLE-SCLEROSIS
    KIDD, D
    THORPE, JW
    THOMPSON, AJ
    KENDALL, BE
    MOSELEY, IF
    MACMANUS, DG
    MCDONALD, WI
    MILLER, DH
    [J]. NEUROLOGY, 1993, 43 (12) : 2632 - 2637
  • [5] Spinal cord atrophy and disability in multiple sclerosis - A new reproducible and sensitive MRI method with potential to monitor disease progression
    Losseff, NA
    Webb, SL
    ORiordan, JI
    Page, R
    Wang, L
    Barker, GJ
    Tofts, PS
    McDonald, WI
    Miller, DH
    Thompson, AJ
    [J]. BRAIN, 1996, 119 : 701 - 708
  • [6] LOSSEFF NA, 1996, EUR J NEUROL, V3, P2
  • [7] Nunally J. C., 1978, Psychometric Methods, V2nd Ed
  • [8] Nunnally JC, 1970, INTRO PSYCHOL MEASUR
  • [9] Spinal cord atrophy and disability in MS - A longitudinal study
    Stevenson, VL
    Leary, SM
    Losseff, NA
    Parker, GJM
    Barker, GJ
    Husmani, Y
    Miller, DH
    Thompson, AJ
    [J]. NEUROLOGY, 1998, 51 (01) : 234 - 238
  • [10] CORRECTION OF NONUNIFORMITY IN IMAGES OF THE SPINE AND OPTIC-NERVE FROM FIXED RECEIVE-ONLY SURFACE COILS AT 1.5-T
    TOFTS, PS
    BARKER, GJ
    SIMMONS, A
    MACMANUS, DG
    THORPE, J
    GASS, A
    MILLER, DH
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (06) : 997 - 1003