Damage Assessment of a Full-Scale Six-Story Wood-Frame Building Following Triaxial Shake Table Tests

被引:13
作者
van de Lindt, John W. [1 ]
Gupta, Rakesh [2 ]
Pei, Shiling [3 ]
Tachibana, Kazuki [4 ]
Araki, Yasuhiro [5 ]
Rammer, Douglas [6 ]
Isoda, Hiroshi [7 ]
机构
[1] Univ Alabama, Dept Civil Construct & Environm Engn, Tuscaloosa, AL 35487 USA
[2] Oregon State Univ, Dept Wood Sci & Engn, Corvallis, OR 97331 USA
[3] S Dakota State Univ, Dept Civil & Environm Engn, Brookings, SD 57007 USA
[4] Univ Tokyo, Tokyo, Japan
[5] Kobe Univ, Kobe, Hyogo 657, Japan
[6] US Forest Serv, Madison, WI 53705 USA
[7] Shinshu Univ, Nagano, Japan
基金
美国国家科学基金会;
关键词
Damage assessment; Earthquake; Shake table; Full-scale experiment; Performance;
D O I
10.1061/(ASCE)CF.1943-5509.0000202
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the summer of 2009, a full-scale midrise wood-frame building was tested under a series of simulated earthquakes on the world's largest shake table in Miki City, Japan. The objective of this series of tests was to validate a performance-based seismic design approach by qualitatively and quantitatively examining the building's seismic performance in terms of response kinematics and observed damage. This paper presents the results of detailed damage inspections following each test in a series of five shake table tests, and explains their qualitative synthesis to provide design method validation. The seismic test program had two phases. Phase I was the testing of a seven-story mixed-use building with the first story consisting of a steel special moment frame (SMF) and stories 2-7 made of light-frame wood. In Phase II, the SMF was heavily braced such that it effectively became an extension of the shake table and testing was conducted on only stories 2-7, making the building a six-story light-frame multifamily residential building instead of a mixed-use building. All earthquake motions were scalings of the 1994 Northridge earthquake at the Canoga Park recording station with seismic intensities ranging from peak ground accelerations of 0.22 to 0.88 g. The building performed quite well during all earthquakes with damage only to the gypsum wall board (drywall), no sill plate splitting, no nails withdrawing or pulling through the sheathing, no edge tearing of the sheathing, no visible stud splitting around tie-down rods, and reasonable floor accelerations. On the basis of damage inspection, it was concluded that it is possible to design this type of building and keep the damage to a manageable level during major earthquakes by utilizing the new design approach. DOI: 10.1061/(ASCE)CF.1943-5509.0000202. (C) 2012 American Society of Civil Engineers
引用
收藏
页码:17 / 25
页数:9
相关论文
共 11 条
[1]  
[Anonymous], SAPWOOD WIND VERS 1
[2]  
[Anonymous], 1998, P 11 EUR C EARTHQ EN
[3]  
CHRISTOVASILIS IP, 2007, NW01 NEES
[4]  
Consortium of Universities for Research in Earthquake Engineering CUREE, 1998, CUREE CALT WOODFR PR
[5]   Performance-based seismic design of wood framed buildings [J].
Filiatrault, A ;
Folz, B .
JOURNAL OF STRUCTURAL ENGINEERING, 2002, 128 (01) :39-47
[6]   Experimental Seismic Response of a Full-Scale Light-Frame Wood Building [J].
Filiatrault, Andre ;
Christovasilis, Ioannis P. ;
Wanitkorkul, Assawin ;
van de Lindt, John W. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (03) :246-254
[7]  
MALIK A, 1995, ESTIMATING BUILDING
[8]  
Pang W. C., 2007, NW02 TEX A M U ZACH
[9]   Simplified Direct Displacement Design of Six-Story Woodframe Building and Pretest Seismic Performance Assessment [J].
Pang, Weichiang ;
Rosowsky, David V. ;
Pei, Shiling ;
van de Lindt, John W. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (07) :813-825
[10]  
Pei S., 2010, NW04 COL STAT U