In vivo evaluation of a dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devices

被引:143
作者
Hickey, T
Kreutzer, D
Burgess, DJ
Moussy, F
机构
[1] Univ Connecticut, Ctr Hlth, Ctr Biomat, Farmington, CT 06032 USA
[2] Univ Connecticut, Ctr Hlth, Dept Pathol, Farmington, CT 06032 USA
[3] Univ Connecticut, Sch Pharm, Storrs, CT 06269 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2002年 / 61卷 / 02期
关键词
PLGA; microspheres; dexamethasone; predegrading; inflammation; glucose sensors; sutures;
D O I
10.1002/jbm.10016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this research effort was to evaluate in vivo a newly developed dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to an implanted device, in this case a biosensor. The microspheres were prepared using an oil/water (O/W) emulsion technique. The microsphere system was composed of drug-loaded microspheres (including newly formulated and predegraded microspheres) and free dexamethasone. The combination of the drug and drug-loaded microspheres provided burst release of dexamethasone followed by continuous release from days 2-14. Continuous release to at least 30 days was achieved by mixing predegraded and newly formulated microspheres. The ability of our mixed microsphere system to control tissue reactions to an implant then was tested in vivo using cotton thread sutures to induce inflammation subcutaneously in Sprague-Dawley rats. Two different in vivo studies were performed, the first to find the dosage level of dexamethasone that effectively would suppress the acute inflammatory reaction and the second to show how effective the dexamethasone delivered by PLGA microspheres was in suppressing chronic inflammatory response to an implant. The first in vivo study showed that 0.1 to 0.8 mg of dexamethasone at the site minimized the acute inflammatory reaction. The second in vivo study showed that our mixed microsphere system suppressed the inflammatory response to an implanted suture for at least I month. This study has proven the viability of microsphere delivery of an anti-inflammatory to control the inflammatory reaction at an implant site. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:180 / 187
页数:8
相关论文
共 24 条
[1]   pH and osmotic pressure inside biodegradable microspheres during erosion [J].
Brunner, A ;
Mäder, K ;
Göpferich, A .
PHARMACEUTICAL RESEARCH, 1999, 16 (06) :847-853
[2]  
BURGESS DB, 1996, PHARM SCI, V2, P223
[3]  
BURGESS DJ, 1994, ENCY PHARM TECHNOLOG, P1
[4]   Delivering neuroactive molecules from biodegradable microspheres for application in central nervous system disorders [J].
Cao, XD ;
Shoichet, MS .
BIOMATERIALS, 1999, 20 (04) :329-339
[5]  
Chiara O, 1997, Minerva Chir, V52, P1095
[6]   Stable formulations of recombinant human growth hormone and interferon-gamma for microencapsulation in biodegradable microspheres [J].
Cleland, JL ;
Jones, AJS .
PHARMACEUTICAL RESEARCH, 1996, 13 (10) :1464-1475
[7]   CONTROLLED DELIVERY SYSTEMS FOR PROTEINS BASED ON POLY(LACTIC GLYCOLIC ACID) MICROSPHERES [J].
COHEN, S ;
YOSHIOKA, T ;
LUCARELLI, M ;
HWANG, LH ;
LANGER, R .
PHARMACEUTICAL RESEARCH, 1991, 8 (06) :713-720
[8]   A classification of NSAIDs according to the relative inhibition of cyclooxygenase isoenzymes [J].
Frolich, JC .
TRENDS IN PHARMACOLOGICAL SCIENCES, 1997, 18 (01) :30-34
[9]   Local intraluminal infusion of biodegradable polymeric nanoparticles - A novel approach for prolonged drug delivery after balloon angioplasty [J].
Guzman, LA ;
Labhasetwar, V ;
Song, CX ;
Jang, YS ;
Lincoff, AM ;
Levy, R ;
Topol, EJ .
CIRCULATION, 1996, 94 (06) :1441-1448
[10]   IN-VITRO AND IN-VIVO EVALUATION OF THYROTROPIN-RELEASING-HORMONE RELEASE FROM COPOLY(DL-LACTIC/GLYCOLIC ACID) MICROSPHERES [J].
HEYA, T ;
OKADA, H ;
OGAWA, Y ;
TOGUCHI, H .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (05) :636-640