Cardiac Perforation and Lead Dislodgement after Implantation of a MR-Conditional Pacing Lead: A Single-Center Experience

被引:20
作者
Elmouchi, Darryl A. [1 ,2 ]
Rosema, Shelly [1 ]
Vanoosterhout, Stacie M. [1 ]
Khan, Mohsin [3 ]
Davis, Alan T. [2 ]
Gauri, Andre J. [1 ,2 ]
Finta, Bohuslav [1 ,2 ]
Woelfel, Alan K. [1 ,2 ]
Chalfoun, Nagib T. [1 ,2 ]
机构
[1] Spectrum Hlth, Frederik Meijer Heart & Vasc Inst, Grand Rapids, MI USA
[2] Michigan State Univ, Coll Human Med, Dept Internal Med, Grand Rapids, MI 49525 USA
[3] Grand Rapids Med Educ Partners, Grand Rapids, MI USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2014年 / 37卷 / 01期
关键词
pacemakers; magnetic resonance imaging; cardiac tamponade; complications; PACEMAKER; COMPLICATIONS; SYSTEM; PREDICTORS; SAFETY;
D O I
10.1111/pace.12293
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveThe purpose of our study was to determine if the rate of lead-related complications was increased with the Medtronic CapSureFix MRI SureScan 5086 MRI pacing lead (5086; Medtronic Inc., Minneapolis, MN, USA) compared to the previous generation of Medtronic CapSureFix Novus 5076 pacing lead (5076). BackgroundThe 5086 lead is a newly introduced active-fixation pacemaker lead designed to be used conditionally in a magnetic resonance (MR) scanner. This lead has specific design changes compared to the previous generation of 5076 pacing leads. MethodsThis study was a retrospective case control study of 65 consecutive patients implanted with two 5086 leads compared to 92 consecutive control patients implanted with two 5076 leads over a 14-month period at a high-volume tertiary care hospital. ResultsPericarditis, pericardial effusion, cardiac tamponade, or death within 30 days of implant were seen in eight patients from the 5086 cohort and two from the 5076 cohort (odds ratio 6.3, 95% confidence interval 1.3-30.8, P = 0.02). Lead dislodgement occurred in four of the 5086 patients and in none of the 5076 patients (P < 0.03). ConclusionsIn a high-volume center, the incidence of pericarditis, cardiac perforation, tamponade, death, and lead dislodgement was significantly higher with the MR-conditional Medtronic 5086 lead when compared to the previous generation Medtronic 5076 lead.
引用
收藏
页码:4 / 10
页数:7
相关论文
共 18 条
[1]  
AGGARWAL RK, 1995, BRIT HEART J, V73, P571
[2]   50th Anniversary of the First Successful Permanent Pacemaker Implantation in the United States: Historical Review and Future Directions [J].
Beck, Hiroko ;
Boden, William E. ;
Patibandla, Sushmitha ;
Kireyev, Dmitriy ;
Gupta, Vipul ;
Campagna, Franklin ;
Cain, Michael E. ;
Marine, Joseph E. .
AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (06) :810-818
[3]   Increased incidence of subacute lead perforation noted with one implantable cardioverter-defibrillator [J].
Danik, Stephan B. ;
Mansour, Moussa ;
Singh, Jagmeet ;
Reddy, Vivek Y. ;
Ellinor, Patrick T. ;
Milan, David ;
Heist, E. Kevin ;
d'Avila, Andre ;
Ruskin, Jeremy N. ;
Mela, Theofanie .
HEART RHYTHM, 2007, 4 (04) :439-442
[4]   Clinical and electrical performance of currently available MRI-safe pacing systems. Do all devices perform in the same way? [J].
Forleo, Giovanni B. ;
Della Rocca, Domenico G. ;
Panattoni, Germana ;
Schirripa, Valentina ;
Sergi, Domenico ;
Magliano, Giulia ;
Tesauro, Manfredi ;
Santini, Luca ;
Romeo, Francesco .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (05) :2340-2341
[5]   Acute Left Hemothorax as a Late Complication of an Active-Fixation Pacemaker Lead [J].
Forleo, Giovanni B. ;
Zeitani, Jacob ;
Perretta, Tommaso ;
Della Rocca, Domenico G. ;
Santini, Luca ;
Simonetti, Giovanni ;
Romeo, Francesco .
ANNALS OF THORACIC SURGERY, 2013, 95 (03) :1081-1084
[6]   Safety and efficacy of a new magnetic resonance imaging-compatible pacing system: Early results of a prospective comparison with conventional dual-chamber implant outcomes [J].
Forleo, Giovanni B. ;
Santini, Luca ;
Della Rocca, Domenico G. ;
Romano, Valentina ;
Papavasileiou, Lida P. ;
Magliano, Giulia ;
Sgueglia, Marianna ;
Romeo, Francesco .
HEART RHYTHM, 2010, 7 (06) :750-754
[7]   Randomized trial of pacemaker and lead system for safe scanning at 1.5 Tesla [J].
Gimbel, J. Rod ;
Bello, David ;
Schmitt, Matthias ;
Merkely, Bela ;
Schwitter, Juerg ;
Hayes, David L. ;
Sommer, Torsten ;
Schloss, Edward J. ;
Chang, Yanping ;
Willey, Sarah ;
Kanal, Emanuel .
HEART RHYTHM, 2013, 10 (05) :685-691
[8]   Delayed lead perforation: A disturbing trend [J].
Khan, MN ;
Joseph, G ;
Khaykin, Y ;
Ziada, KM ;
Wilkoff, BL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (03) :251-253
[9]   First MRI-Safe Pacemaker Receives Conditional Approval From FDA [J].
Mitka, Mike .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2011, 305 (10) :985-986
[10]   How to perform magnetic resonance imaging on patients with implantabte cardiac arrhythmia devices [J].
Nazarian, Saman ;
Halperin, Henry R. .
HEART RHYTHM, 2009, 6 (01) :138-143