A simple and sensitive electrochemical sensor for rapid detection of Clostridium tetani based on multi-walled carbon nanotubes

被引:10
作者
Liu, Xiaobo [1 ]
Du, Chunlan [1 ]
Ni, Danni [1 ]
Ran, Qiaosheng [1 ]
Liu, Fei [1 ]
Jiang, Dongneng [1 ]
Pu, Xiaoyun [1 ]
机构
[1] Third Mil Med Univ, Dept Clin Lab, Xinqiao Hosp, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
ROLLING-CIRCLE AMPLIFICATION; MEDIATED ISOTHERMAL AMPLIFICATION; TIME PCR ASSAYS; DNA SENSOR; SEQUENCE; NEUROTOXIN; PRIMERS; TOXIN;
D O I
10.1039/c6ay01025c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tetanus is a common disease caused by anaerobic bacteria called Clostridium tetani in deep tissue infections. Once the vulnus is infected with C. tetani, the risk for amputation and mortality increases greatly. Therefore, it is necessary to design a rapid and sensitive detection method for the early diagnosis and clinical treatment of tetanus. In this research, we developed a detection method for C. tetani using an electrochemical biosensor on the basis of an improved rolling circle amplification (iRCA) assay, wherein the tetanus toxin gene was used as the target gene. The biosensor was coated by probes that capture C. tetani DNA after amplification; then, the sensor was hybridized with detection probes that are combined with methylene blue (MB). Compared with the culture method, PCR technology and the traditional loop-mediated isothermal amplification (LAMP) method, this method is not only simple and rapid, but can also be identified through an electrochemical analyser. Additionally, this method has good stability, strong specificity, and high sensitivity with a detection limit of 1.0 x 10(-16) M, and quantitative analysis could be realized. Therefore, this method is ideal and rapid in detecting C. tetani, thus broadening the use of the DNA amplification method and holding great promise for future ultrasensitive bioassays.
引用
收藏
页码:8280 / 8287
页数:8
相关论文
共 26 条
[1]   Improvement in laboratory diagnosis of wound botulism and tetanus among injecting illicit-drug users by use of real-time PCR assays for neurotoxin gene fragments [J].
Akbulut, D ;
Grant, KA ;
McLauchlin, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (09) :4342-4348
[2]  
Chaves F, 2006, REV BIOL TROP, V54, P253
[3]   An electrochemical DNA sensor for sequence-specific DNA recognization in a homogeneous solution [J].
Cui, Han-Feng ;
Cheng, Lin ;
Zhang, Jie ;
Liu, Ronghua ;
Zhang, Cheng ;
Fan, Hao .
BIOSENSORS & BIOELECTRONICS, 2014, 56 :124-128
[4]   Electrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode [J].
Dai, Z ;
Chen, J ;
Yan, F ;
Ju, HX .
CANCER DETECTION AND PREVENTION, 2005, 29 (03) :233-240
[5]  
Demidov Vadim V, 2002, Expert Rev Mol Diagn, V2, P542, DOI 10.1586/14737159.2.6.542
[6]   In silico design and experimental screening of real-time PCR assays for the detection of Clostridium perfringens and Clostridium tetani toxin genes [J].
Doggett, N. ;
Gans, J. ;
Henrie, M. ;
Dighe, P. ;
Wolinsky, M. .
TOXICON, 2013, 68 :84-84
[7]   Detection of Clostridium tetani in human clinical samples using tetX specific primers targeting the neurotoxin [J].
Ganesh, Madhu ;
Sheikh, Nasira K. ;
Shah, Pooja ;
Mehetre, Gajanan ;
Dharne, Mahesh S. ;
Nagoba, Basavraj S. .
JOURNAL OF INFECTION AND PUBLIC HEALTH, 2016, 9 (01) :105-109
[8]   Clostridium tetani bacteraemia [J].
Hallit, Rabih Riad ;
Afridi, Muhammad ;
Sison, Raymund ;
Salem, Elie ;
Boghossian, Jack ;
Slim, Jihad .
JOURNAL OF MEDICAL MICROBIOLOGY, 2013, 62 :155-156
[9]   Rapid, Sensitive, and Quantitative Detection of Pathogenic DNA at the Point of Care through Microfluidic Electrochemical Quantitative Loop-Mediated Isothermal Amplification [J].
Hsieh, Kuangwen ;
Patterson, Adriana S. ;
Ferguson, B. Scott ;
Plaxco, Kevin W. ;
Soh, H. Tom .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (20) :4896-4900
[10]  
Jiang DN, 2012, INT J ELECTROCHEM SC, V7, P10607