Formulation of a Nondestructive Technique for Evaluating Steel Corrosion in Concrete Structures

被引:7
|
作者
Lim, Young-Chul [1 ]
Noguchi, Takafumi [2 ]
Shin, Sung-Woo [1 ]
机构
[1] Hanyang Univ, Sustainable Bldg Res Ctr, Ansan 426791, South Korea
[2] Univ Tokyo, Fac Engn, Dept Architecture, Tokyo 1138656, Japan
关键词
corrosion; steel; completely nondestructive technique; equivalent circuit; polarization resistance; concrete resistivity;
D O I
10.2355/isijinternational.49.275
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
This paper reports on a fundamental study on the formulation of a corrosion evaluation system for reinforced concrete structures based on a completely nondestructive technique. This is a method of evaluating the polarization resistance produced at the boundary between concrete and steel, without destroying the concrete surface, to estimate the resulting corrosion current density. A method of estimating the resistivity distribution within concrete to examine the steel corrosion environment is also proposed. This system consists of an equivalent circuit, a resistivity model for examining the effect of concrete, i.e., the measurement medium, and an actual measurement system. The equivalent circuit takes account of the electrode arrangement for resistivity measurement, and the impedance within concrete. This technique was verified by tests using specimens with controlled corrosion losses and was proven to express corrosion deterioration within concrete well. Evaluation by this technique was thus found feasible.
引用
收藏
页码:275 / 283
页数:9
相关论文
共 50 条
  • [31] Practical model for predicting corrosion rate of steel reinforcement in concrete structures
    Yu, Bo
    Yang, LuFeng
    Wu, Ming
    Li, Bing
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 54 : 385 - 401
  • [32] The study to the corrosion of reinforcing steel in concrete by using Galvanostatic Pulse Technique
    Dou, Yantao
    Hao, Baohong
    Meng, Bo
    Xie, Jun
    Dong, Mingliang
    Zhang, Aolin
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 916 - +
  • [33] Assessment of corrosion of steel in concrete structures by magnetic based NDE techniques
    Ghorbanpoor, A
    Shi, S
    TECHNIQUES TO ASSESS THE CORROSION ACTIVITY OF STEEL REINFORCED CONCRETE STRUCTURES, 1996, 1276 : 119 - 131
  • [34] Damage Mechanics Applied for Steel Reinforcements in Concrete Structures Under Corrosion
    de Souza, Josenaldo Bastos
    de Deus, Enio Pontes
    20TH EUROPEAN CONFERENCE ON FRACTURE, 2014, 3 : 2000 - 2005
  • [35] Reliability of Electrochemical Techniques to Predict the Corrosion Rate of Steel in Concrete Structures
    Vedalakshmi, R.
    Thangavel, K.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2011, 36 (05) : 769 - 783
  • [36] Field and laboratory experience with electrochemical methods for assessing corrosion of steel in concrete
    Videm, K
    ELECTROCHEMICAL METHODS IN CORROSION RESEARCH VI, PTS 1 AND 2, 1998, 289-2 : 3 - 14
  • [37] Corrosion control of steel-reinforced concrete
    D. D. L. Chung
    Journal of Materials Engineering and Performance, 2000, 9 : 585 - 588
  • [38] Embeddable corrosion rate-measuring sensor for assessing the corrosion risk of steel in concrete structures
    Vedalakshmi, R.
    Dolli, H.
    Palaniswamy, N.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2009, 16 (04) : 441 - 459
  • [39] The Effect of Styrofoam on the Corrosion of Steel Reinforced Concrete
    Kelestemur, Oguzhan
    Yildiz, Servet
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2005, 8 (03): : 311 - 315
  • [40] Corrosion control of steel-reinforced concrete
    Chung, DDL