Formulation of a Nondestructive Technique for Evaluating Steel Corrosion in Concrete Structures

被引:7
|
作者
Lim, Young-Chul [1 ]
Noguchi, Takafumi [2 ]
Shin, Sung-Woo [1 ]
机构
[1] Hanyang Univ, Sustainable Bldg Res Ctr, Ansan 426791, South Korea
[2] Univ Tokyo, Fac Engn, Dept Architecture, Tokyo 1138656, Japan
关键词
corrosion; steel; completely nondestructive technique; equivalent circuit; polarization resistance; concrete resistivity;
D O I
10.2355/isijinternational.49.275
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
This paper reports on a fundamental study on the formulation of a corrosion evaluation system for reinforced concrete structures based on a completely nondestructive technique. This is a method of evaluating the polarization resistance produced at the boundary between concrete and steel, without destroying the concrete surface, to estimate the resulting corrosion current density. A method of estimating the resistivity distribution within concrete to examine the steel corrosion environment is also proposed. This system consists of an equivalent circuit, a resistivity model for examining the effect of concrete, i.e., the measurement medium, and an actual measurement system. The equivalent circuit takes account of the electrode arrangement for resistivity measurement, and the impedance within concrete. This technique was verified by tests using specimens with controlled corrosion losses and was proven to express corrosion deterioration within concrete well. Evaluation by this technique was thus found feasible.
引用
收藏
页码:275 / 283
页数:9
相关论文
共 50 条
  • [21] Corrosion rate of steel in concrete - From laboratory to reinforced structures
    Elsener, B
    ELECTROCHEMICAL METHODS IN CORROSION: RESEARCH AND APPLICATION, 1997, 247 : 127 - 137
  • [22] Challenges and opportunities in corrosion of steel in concrete
    Angst, Ueli M.
    MATERIALS AND STRUCTURES, 2018, 51 (01)
  • [23] Erosion and corrosion of steel in fresh concrete
    Cabrini, M.
    Cortellini, M.
    Lorenzi, S.
    Marcassoli, P.
    Pastore, T.
    METALLURGIA ITALIANA, 2010, (05): : 39 - 44
  • [24] CORROSION MONITORING SENSOR IN CONCRETE STRUCTURES BASED ON THE GALVANO-STATIC PULSE TECHNIQUE
    Shuang, Lu
    Zheng, Wang
    REVISTA ROMANA DE MATERIALE-ROMANIAN JOURNAL OF MATERIALS, 2012, 42 (04): : 399 - 404
  • [25] Nondestructive inspection of reinforced concrete structures
    Miller, Tri Huu
    Yanagita, Tamaki
    Kundu, Tribikram
    Grill, Julian
    Grill, Wolfgang
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2009, 2009, 7295
  • [26] The importance of chloride content at the concrete surface in assessing the time to corrosion of steel in concrete structures
    Ann, K. Y.
    Ahn, J. H.
    Ryou, J. S.
    CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (01) : 239 - 245
  • [27] Eddy current technique as a nondestructive method for evaluating the degree of sensitization of 304 stainless steel
    Kelidari, Yeganeh
    Kashefi, Mehrdad
    Mirjalili, Mostafa
    Seyedi, Mahla
    Krause, Thomas W.
    CORROSION SCIENCE, 2020, 173 (173)
  • [28] Corrosion Detection in Steel-Reinforced Concrete Using a Spectroscopic Technique
    Garboczi, E. J.
    Stutzman, P. E.
    Wang, S.
    Martys, N. S.
    Hassan, A. M.
    Duthinh, D.
    Provenzano, V.
    Chou, S. G.
    Plusquellic, D. F.
    Surek, J. T.
    Kim, S.
    McMichael, R. D.
    Stiles, M. D.
    40TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 10TH INTERNATIONAL CONFERENCE ON BARKHAUSEN NOISE AND MICROMAGNETIC TESTING, VOLS 33A & 33B, 2014, 1581 : 769 - 772
  • [29] Effect of corrosion on bond slipping between steel and concrete in SRC structures
    Lin, Yongjun
    Zhong, Shuiyun
    Yu, Guofei
    Sun, Liwen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 220
  • [30] Numerical model for prediction of corrosion of steel reinforcements in reinforced concrete structures
    Ouzaa, Kheira
    Oucif, Chahmi
    UNDERGROUND SPACE, 2019, 4 (01) : 72 - 77