Formulation of a Nondestructive Technique for Evaluating Steel Corrosion in Concrete Structures

被引:7
|
作者
Lim, Young-Chul [1 ]
Noguchi, Takafumi [2 ]
Shin, Sung-Woo [1 ]
机构
[1] Hanyang Univ, Sustainable Bldg Res Ctr, Ansan 426791, South Korea
[2] Univ Tokyo, Fac Engn, Dept Architecture, Tokyo 1138656, Japan
关键词
corrosion; steel; completely nondestructive technique; equivalent circuit; polarization resistance; concrete resistivity;
D O I
10.2355/isijinternational.49.275
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
This paper reports on a fundamental study on the formulation of a corrosion evaluation system for reinforced concrete structures based on a completely nondestructive technique. This is a method of evaluating the polarization resistance produced at the boundary between concrete and steel, without destroying the concrete surface, to estimate the resulting corrosion current density. A method of estimating the resistivity distribution within concrete to examine the steel corrosion environment is also proposed. This system consists of an equivalent circuit, a resistivity model for examining the effect of concrete, i.e., the measurement medium, and an actual measurement system. The equivalent circuit takes account of the electrode arrangement for resistivity measurement, and the impedance within concrete. This technique was verified by tests using specimens with controlled corrosion losses and was proven to express corrosion deterioration within concrete well. Evaluation by this technique was thus found feasible.
引用
收藏
页码:275 / 283
页数:9
相关论文
共 50 条
  • [1] Nondestructive measurement of corrosion state of reinforcing steel in concrete
    Monteiro, PJM
    Morrison, F
    Frangos, W
    ACI MATERIALS JOURNAL, 1998, 95 (06) : 704 - 709
  • [2] Impact of mechanical loading on the corrosion of steel reinforcement in concrete structures
    Ababneh, Ayman
    Sheban, Mashal
    MATERIALS AND STRUCTURES, 2011, 44 (06) : 1123 - 1137
  • [3] Impact of mechanical loading on the corrosion of steel reinforcement in concrete structures
    Ayman Ababneh
    Mashal Sheban
    Materials and Structures, 2011, 44 : 1123 - 1137
  • [4] Integrated Sensor Network for Monitoring Steel Corrosion in Concrete Structures
    Enrique Ramon, Jose
    Manuel Gandia-Romero, Jose
    Valcuende, Manuel
    Bataller, Roman
    VITRUVIO-INTERNATIONAL JOURNAL OF ARCHITECTURAL TECHNOLOGY AND SUSTAINABILITY, 2016, 1 (01): : 65 - 79
  • [5] Steel corrosion damage monitoring in reinforced concrete structures with the acoustic emission technique: A review
    Verstrynge, Els
    Van Steen, Charlotte
    Vandecruys, Eline
    Wevers, Martine
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 349
  • [6] Effectiveness of impressed current technique to simulate corrosion of steel reinforcement in concrete
    El Maaddawy, TA
    Soudki, KA
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2003, 15 (01) : 41 - 47
  • [7] Nondestructive technique application for corrosion evaluation by hydrogen charging of stainless steel
    Lee, Jin Kyung
    Bae, Dong Su
    Lee, Sang Pill
    Hwang, Sung Guk
    Lee, Joon Hyun
    FUSION ENGINEERING AND DESIGN, 2016, 109 : 752 - 759
  • [8] Numerical Simulation of Concrete Structures after Steel Corrosion
    Li, Chunsheng
    Gu, Xiaoping
    ICMS2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION, VOL 2: MODELLING AND SIMULATION IN ENGINEERING, 2010, : 409 - 412
  • [9] The Effect of Steel Corrosion on Bond Strength in Concrete Structures
    方从启
    寇新建
    Journal of Shanghai Jiaotong University, 2005, (04) : 436 - 440
  • [10] Millimeter wave nondestructive evaluation of corrosion under paint in steel structures
    Kharkovsky, S
    Zoughi, R
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 25A AND 25B, 2006, 820 : 1277 - 1283