A polymeric chemosensor for Fe3+ based on fluorescence quenching of polymer with quinoline derivative in the side chain

被引:48
作者
Li, Najun [1 ]
Xu, Qingfeng [1 ]
Xia, Xuewei [1 ]
Wang, Lihua [1 ]
Lu, Jianmei [1 ]
Wen, Xiaowei [1 ]
机构
[1] Suzhou Univ, Sch Chem & Chem Engn, Key Lab Organ Synth Jiangsu Prov, Suzhou 215123, Jiangsu, Peoples R China
关键词
Quinoline; Fluorescence quenching; Ferric ion; Polymeric chemosensor; CONJUGATED POLYMERS; METAL-IONS; SPECTROPHOTOMETRIC DETERMINATION; SENSOR; IRON; FE(III); DESIGN;
D O I
10.1016/j.matchemphys.2008.09.027
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The synthesis and photophysics of a blue fluorescent polymer with a quinoline derivative in the side chain have been described. The sensitivity of poly(HQPEMA) to transition-metal ions such as Fe3+, Zn2+, Co2+, Cu2+, and so forth has been explored by fluorescence emission spectroscopy. The results showed that the fluorescence of the polymer was significantly quenched by the addition of the ferric ion. The high selectivity and sensitivity for Fe3+ were observed in different organic solvents such as N,N-dimethylformamide, tetrahydrofuran, 1, 2-dichlorethane and chloroform. The polymer as a fluorescent sensor toward Fe3+ was investigated in detail. The fluorescence quenching was found to be a linear relationship with Fe3+ concentration. The fluorescence quenching behavior is a typical Stem-Volmer quenching with a Stem-Volmer constant (Ksv) of 1.44 x 10(4) M-1. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 33 条
  • [1] DMAS JN, 1971, J PHYS CHEM-US, V71, P991
  • [2] Spectrophotometric determination of iron and boron in soil extracts using a multi-syringe flow injection system
    Gomes, DMC
    Segundo, MA
    Lima, JLFC
    Rangel, AOSS
    [J]. TALANTA, 2005, 66 (03) : 703 - 711
  • [3] New series of light-emitting polyquinolines containing 9,9′-spirobifluorene units
    Huang, B
    Li, J
    Jiang, ZQ
    Qin, JG
    Yu, G
    Liu, YQ
    [J]. MACROMOLECULES, 2005, 38 (16) : 6915 - 6922
  • [4] Kim J, 2000, ANGEW CHEM INT EDIT, V39, P3868, DOI 10.1002/1521-3773(20001103)39:21<3868::AID-ANIE3868>3.0.CO
  • [5] 2-2
  • [6] Kimura M, 1998, ADV MATER, V10, P459, DOI 10.1002/(SICI)1521-4095(199804)10:6<459::AID-ADMA459>3.0.CO
  • [7] 2-A
  • [8] A fluorescent metal sensor based on macrocyclic chelation
    Klein, G
    Kaufmann, D
    Schürch, S
    Reymond, JL
    [J]. CHEMICAL COMMUNICATIONS, 2001, (06) : 561 - 562
  • [9] Leclerc M, 1999, ADV MATER, V11, P1491, DOI 10.1002/(SICI)1521-4095(199912)11:18<1491::AID-ADMA1491>3.0.CO
  • [10] 2-O