A review of current devices and a look at new technology: drug-eluting stents

被引:49
作者
Nakazawa, Gaku [1 ]
Finn, Aloke V. [2 ]
Kolodgie, Frank D. [1 ]
Virmani, Renu [1 ]
机构
[1] CVPath Inst Inc, Gaithersburg, MD 20878 USA
[2] Emory Univ, Sch Med, Atlanta, GA USA
关键词
biodegradable polymer; drug-eluting stent; new technology; stent design; CORONARY-ARTERY-DISEASE; MUSCLE-CELL-PROLIFERATION; TISSUE FACTOR EXPRESSION; MYOCARDIAL-INFARCTION; NEOINTIMAL COVERAGE; RANDOMIZED-TRIAL; FOLLOW-UP; PACLITAXEL; POLYMER; RESTENOSIS;
D O I
10.1586/17434440.6.1.33
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Drug-eluting stents (DES) have become the standard of care for the treatment of coronary artery disease. However, late stent thrombosis has emerged as a major concern, especially in 'off-label' use. Pathologic studies of patients dying from late DES thrombosis demonstrate delayed arterial healing, characterized by persistent fibrin deposition and poor endothelialization as the primary substrate. Therefore, next-generation DES are being developed to increase the safety and biocompatibility by optimizing the three major components of DES: the stent platform, the polymer and the drug. Stents with thinner struts are endothelialized rapidly and cause less vessel-wall injury. Non-erodable polymers applied thinly and without defect or cracking cause less inflammation and will result in better long-term safety. Furthermore, use of biodegradable polymers, which fully degrade and leave a bare metal stent, will result in less inflammation. The choice of drug, dose and release kinetics should also be optimized. In addition to the improvement of DES components, new approaches, such as polymer-free drug delivery, prohealing approach and fully biodegradable stents, are emerging. Importantly, these technologies focus not only on efficacy but also on safety. The next-generation DES will probably be safer, with goals of improving endothelialization and more rapid arterial healing compared with first- and second-generation DES.
引用
收藏
页码:33 / 42
页数:10
相关论文
共 67 条
[1]   Taxanes: Microtubule and Centrosome Targets, and Cell Cycle Dependent Mechanisms of Action [J].
Abal, M. ;
Andreu, J. M. ;
Barasoain, I. .
CURRENT CANCER DRUG TARGETS, 2003, 3 (03) :193-203
[2]   Occupational allergies caused by latex [J].
Ahmed, DDF ;
Sobczak, SC ;
Yunginger, JW .
IMMUNOLOGY AND ALLERGY CLINICS OF NORTH AMERICA, 2003, 23 (02) :205-+
[3]   Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients [J].
Aoki, J ;
Abizaid, AC ;
Serruys, PW ;
Ong, ATL ;
Boersma, E ;
Sousa, JE ;
Bruining, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (09) :1670-1676
[4]   Endothelial progenitor cell capture by stents coated with antibody against CD34 - The HEALING-FIM (healthy endothelial accelerated lining inhibits neointimal growth-first in man) registry [J].
Aoki, J ;
Serruys, PW ;
van Beusekom, H ;
Ong, ATL ;
McFadden, EP ;
Sianos, G ;
van der Giessen, WJ ;
Regar, E ;
de Feyter, PJ ;
Davis, HR ;
Rowland, S ;
Kutryk, MJB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (10) :1574-1579
[5]   Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation [J].
Awata, Masaki ;
Kotani, Jun-ichi ;
Uematsu, Masaaki ;
Morozumi, Takakazu ;
Watanabe, Tetsuya ;
Onishi, Toshinari ;
Iida, Osamu ;
Sera, Fusako ;
Nanto, Shinsuke ;
Hori, Masatsugu ;
Nagata, Seiki .
CIRCULATION, 2007, 116 (08) :910-916
[6]  
Barrows T., 1986, Clinical materials, V1, P233, DOI [DOI 10.1016/S0267-6605(86)80015-4, 10.1016/S0267-6605(86)80015-4]
[7]  
BEIJK MA, 2005, EUROINTERVENTION, V1, P266
[8]   MORPHOLOGIC CHARACTERISTICS OF LESION FORMATION AND TIME-COURSE OF SMOOTH-MUSCLE CELL-PROLIFERATION IN A PORCINE PROLIFERATIVE RESTENOSIS MODEL [J].
CARTER, AJ ;
LAIRD, JR ;
FARB, A ;
KUFS, W ;
WORTHAM, DC ;
VIRMANI, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) :1398-1405
[9]   THE EFFECT OF PH ON THE INVITRO DEGRADATION OF POLY(GLYCOLIDE LACTIDE) CO-POLYMER ABSORBABLE SUTURES [J].
CHU, CC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (02) :117-124
[10]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678