Intra- and inter-rater reliability of jumping mechanography muscle function assessments

被引:0
|
作者
Matheson, L. A. [1 ]
Duffy, S. [1 ]
Maroof, A. [1 ]
Gibbons, R. [1 ]
Duffy, C. [1 ,2 ]
Roth, J. [1 ,2 ]
机构
[1] Childrens Hosp Eastern Ontario, Div Pediat Rheumatol, Ottawa, ON K1H 8L1, Canada
[2] Univ Ottawa, Dept Pediat, Ottawa, ON K1N 6N5, Canada
基金
加拿大健康研究院;
关键词
Reproducibility; Muscle Function; Mechanography; Force; Power; TEST-RETEST RELIABILITY; LEG STIFFNESS; STRIDE FREQUENCY; ANKLE STIFFNESS; COUNTERMOVEMENT; REPRODUCIBILITY; CHILDREN; HEIGHT; FORCE;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Muscle function can be assessed through jumping mechanography, where portable ground reaction force plates collect dynamic information as a subject jumps. The aim of this study was to assess both intra-and inter-rater reliability of jumping mechanography. Ten healthy adults underwent 3 sets of testing (collected by 3 different raters) at two separate sessions, one week apart. They performed a number of tests in each session: multiple one-legged hopping (M1LH; on right and left legs) and single two-legged jumps (S2LJ; with or without arm swing). The S2LJ assessed variables of power per body mass, jump height, velocity and efficiency; whereas, M1LH assessed maximum force per body mass and stiffness. Inter-rater coefficients of variation (CV) were less than 0.6% and 2.6% for the S2LJ and M1LH, respectively, for the primary outcome variables of power/body mass and force/body mass. Analyzing intra-rater results also produced CVs less than 5.3% for all variables. The present study reports that the Leonardo ground reaction force plate system yields reproducible results between sessions, without significant contribution of variability from the test operator. Jumping mechanography is an easy, safe and reliable method for the assessment of lower limb musculoskeletal function.
引用
收藏
页码:480 / 486
页数:7
相关论文
共 50 条
  • [1] Inter-Rater Reliability and Measurement Error of Sonographic Muscle Architecture Assessments
    Koenig, Niklas
    Cassel, Michael
    Intziegianni, Konstantina
    Mayer, Frank
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (05) : 769 - 777
  • [2] Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
    Martinho, Natalia M.
    Marques, Joseane
    Silva, Valeria R.
    Silva, Silvia L. A.
    Carvalho, Leonardo C.
    Botelho, Simone
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2015, 19 (02) : 97 - 104
  • [3] Pain pressure threshold algometry in knee osteoarthritis: intra- and inter-rater reliability
    Stausholm, Martin Bjorn
    Bjordal, Jan Magnus
    Moe-Nilssen, Rolf
    Naterstad, Ingvill Fjell
    PHYSIOTHERAPY THEORY AND PRACTICE, 2023, 39 (03) : 615 - 622
  • [4] Intra- and inter-rater reliability of goniometric finger range of motion using a written protocol
    Nakai, Takuya
    Amano, Satoru
    Murao, Chikako
    Taguchi, Haruki
    Takahashi, Kayoko
    ARCHIVES OF PHYSIOTHERAPY, 2024, 14 (01) : 83 - 88
  • [5] Tele-Assessment of Functional Capacity: Validity, Intra- and Inter-rater Reliability
    Asliyüce, Yasemin Ozel
    Fanuscu, Aybuke
    Asliyüce, Abdurahim
    Ülger, Ozlem
    WORKPLACE HEALTH & SAFETY, 2023, 71 (10) : 476 - 483
  • [6] Intra- and inter-rater reliability of movement and palpation tests in patients with neck pain: A systematic review
    Jonsson, Anders
    Rasmussen-Barr, Eva
    PHYSIOTHERAPY THEORY AND PRACTICE, 2018, 34 (03) : 165 - 180
  • [7] Intra- and Inter-rater Reliability of Peripheral Arterial Blood Flow Velocity by Means of Doppler Ultrasound
    de Oliveira Guirro, Elaine Caldeira
    Marcondes Ferreira Leite, Gabriella de Paula
    Dibai-Filho, Almir Vieira
    de Souza Borges, Nathalia Cristina
    de Jesus Guirro, Rinaldo Roberto
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2017, 40 (04) : 236 - 240
  • [8] Test-retest, intra- and inter-rater reliability of the reactive balance test in healthy recreational athletes
    Tassignon, Bruno
    Verschueren, Jo
    De Wachter, Jonas
    Maricot, Alexandre
    De Pauw, Kevin
    Verhagen, Evert
    Meeusen, Romain
    PHYSICAL THERAPY IN SPORT, 2020, 46 : 47 - 53
  • [9] The intra- and inter-rater reliability of X-ray radiological measurements for patellar instability
    Smith, T. O.
    Cogan, A.
    Patel, S.
    Shakokani, M.
    Toms, A. P.
    Donell, S. T.
    KNEE, 2013, 20 (02) : 133 - 138
  • [10] Evaluation of the Lower Trapezius Muscle Using Ultrasound Panoramic View (a Novel Approach): An Intra- and Inter-Rater Reliability Study
    Fernandez-Carnero, Samuel
    Garrido-Marin, Alejandro
    Achalandabaso-Ochoa, Alexander
    Ferragut-Garcias, Alejandro
    Fernandez-Matias, Ruben
    Pecos-Martin, Daniel
    Gallego-Izquierdo, Tomas
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (19) : 1 - 10