Dose and volume reduction for normal lung using intensity-modulated radiotherapy for advanced-stage non-small-cell lung cancer

被引:204
作者
Murshed, H
Liu, HH
Liao, ZX
Barker, JL
Wang, XC
Tucker, SL
Chandra, A
Guerrero, T
Stevens, C
Change, JY
Jeter, M
Cox, JD
Komaki, R
Mohan, R
机构
[1] Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Unit 94, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Biomath, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 58卷 / 04期
关键词
D O I
10.1016/j.ijrobp.2003.09.086
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate dosimetric improvements with respect to tumor-dose conformity and normal tissue sparing using intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3D-CRT) for advanced-stage non-small-cell lung cancer (NSCLC). Methods and Materials: Forty-one patients with Stage III-IV and recurrent NSCLC who previously underwent 3D-CRT were included. IMRT plans were designed to deliver 63 Gy to 95% of the planning target volume using nine equidistant coplanar 6-MV beams. Inverse planning was performed to minimize the volumes of normal lung, heart, esophagus, and spinal cord irradiated above their tolerance doses. Dose distributions and dosimetric indexes for the tumors and critical structures in both plans were computed and compared. Results: Using IMRT, the median absolute reduction in the percentage of lung volume irradiated to >10 and >20 Gy was 7% and 10%, respectively. This corresponded to a decrease of >2 Gy in the total lung mean dose and of 10% in the risk of radiation pneumonitis. The volumes of the heart and esophagus irradiated to >40-50 Gy and normal thoracic tissue volume irradiated to >10-40 Gy were reduced using the IMRT plans. A marginal increase occurred in the spinal cord maximal dose and lung volume >5 Gy in the IMRT plans, which could be have resulted from the significant increase in monitor units and thus leakage dose in IMRT. Conclusion: IMRT planning significantly improved target coverage and reduced the volume of normal lung irradiated above low doses. The spread of low doses to normal tissues can be controlled in IMRT with appropriately selected planning parameters. The dosimetric benefits of IMRT for advanced-stage non-small-cell lung cancer must be evaluated further in clinical trials. (C) 2004 Elsevier Inc.
引用
收藏
页码:1258 / 1267
页数:10
相关论文
共 28 条
  • [1] Promising survival with three-dimensional conformal radiation therapy for non-small cell lung cancer
    Armstrong, J
    Raben, A
    Zelefsky, M
    Burt, M
    Leibel, S
    Burman, C
    Kutcher, G
    Harrison, L
    Hahn, C
    Ginsberg, R
    Rusch, V
    Kris, M
    Fuks, Z
    [J]. RADIOTHERAPY AND ONCOLOGY, 1997, 44 (01) : 17 - 22
  • [2] EFFECT OF CHEMOTHERAPY ON LOCALLY ADVANCED NON-SMALL-CELL LUNG-CARCINOMA - A RANDOMIZED STUDY OF 353 PATIENTS
    ARRIAGADA, R
    LECHEVALIER, T
    QUOIX, E
    RUFFIE, P
    DECREMOUX, H
    DOUILLARD, JY
    TARAYRE, M
    PIGNON, JP
    LAPLANCHE, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (06): : 1183 - 1190
  • [3] Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation
    Bortfeld, T
    Jokivarsi, K
    Goitein, M
    Kung, J
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (13) : 2203 - 2220
  • [4] Intensity-modulated radiotherapy: Current status and issues of interest
    Boyer, AL
    Butler, EB
    DiPetrillo, TA
    Engler, MJ
    Fraass, B
    Grant, W
    Ling, CC
    Low, DA
    Mackie, TR
    Mohan, R
    Purdy, JA
    Roach, M
    Rosenman, JG
    Verhey, LJ
    Wong, JW
    Cumberlin, RL
    Stone, H
    Palta, JR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04): : 880 - 914
  • [5] FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION
    BURMAN, C
    KUTCHER, GJ
    EMAMI, B
    GOITEIN, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 123 - 135
  • [6] The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator
    Chui, CS
    Yorke, E
    Hong, L
    [J]. MEDICAL PHYSICS, 2003, 30 (07) : 1736 - 1746
  • [7] An evaluation of two techniques for beam intensity modulation in patients irradiated for stage III non-small cell lung cancer
    de Koste, JV
    Voet, P
    Dirkx, M
    van Meerbeeck, J
    Senan, S
    [J]. LUNG CANCER, 2001, 32 (02) : 145 - 153
  • [8] Parotid gland sparing in patients undergoing bilateral head and neck irradiation: Techniques and early results
    Eisbruch, A
    Ship, JA
    Martel, MK
    TenHaken, RK
    Marsh, LH
    Wolf, GT
    Esclamado, RM
    Bradford, CR
    Terrell, JE
    Gebarski, SS
    Lichter, AS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (02): : 469 - 480
  • [9] TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION
    EMAMI, B
    LYMAN, J
    BROWN, A
    COIA, L
    GOITEIN, M
    MUNZENRIDER, JE
    SHANK, B
    SOLIN, LJ
    WESSON, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 109 - 122
  • [10] Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)
    Graham, MV
    Purdy, JA
    Emami, B
    Harms, W
    Bosch, W
    Lockett, MA
    Perez, CA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02): : 323 - 329