Left ventricular mass regression following implantation of MIRA bileaflet valves in patients with severe aortic stenosis

被引:3
作者
Toggweiler, Stefan [1 ]
Zuber, Michel [1 ]
Gerber, Katharina [2 ]
Schlaepfer, Reinhard [2 ]
Erne, Paul [1 ]
Stulz, Peter [2 ]
机构
[1] Kantonsspital Luzern, Div Cardiol, CH-6000 Luzern, Switzerland
[2] Kantonsspital Luzern, Dept Cardiothorac Surg, CH-6000 Luzern, Switzerland
关键词
Aortic valve prosthesis; Left ventricular hypertrophy; Left ventricular mass regression; Echocardiography; MIRA valve; REPLACEMENT; HYPERTROPHY; PROSTHESIS; HEART; SIZE;
D O I
10.1007/s00380-008-1068-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to evaluate the factors that determine the course of left ventricular mass regression in a homogeneous group of patients following aortic valve replacement by use of the mechanical Edwards MIRA bileaflet prosthesis. Furthermore, we examined if the 19-mm valve leads to an equally good outcome when compared with larger 21- and 23-mm valves. We included 79 patients (49 men) with a mean age of 65 +/- 9 years operated on for isolated aortic valve replacement with the MIRA valve prosthesis. The analyses included preoperative and postoperative echocardiograms during a follow-up of at least 18 months (995 +/- 439 days) after valve surgery. Indication for valve replacement was aortic stenosis in 59 and combined disease (aortic stenosis and regurgitation) in 20 patients. Concomitant coronary artery bypass grafting was performed in 28 patients. Left ventricular mass index declined from 155.6 +/- 47 g/m(2) to 128.8 +/- 35 g/m(2) (P < 0.001) at final visit and normalized in 49% of the patients. Female sex and a preoperatively highly elevated left ventricular mass index were identified as risk factors for residual hypertrophy. However, age and valve size did not have a predictive value for completeness of left ventricular mass regression. This study supports the evidence that an extensive preoperative left ventricular hypertrophy results in an incomplete postoperative mass regression in patients with aortic bileaflet valves. It shows that the slightly elevated pressure gradient in MIRA 19-mm valves does not affect left ventricular mass regression.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 16 条
[1]   Influence of aortic valve replacement, prosthesis type, and size on functional outcome and ventricular mass in patients with aortic stenosis [J].
Bech-Hanssen, O ;
Caidahl, K ;
Wall, B ;
Mykén, P ;
Larsson, S ;
Wallentin, I .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (01) :57-65
[2]   Regression of hypertensive left ventricular hypertrophy by losartan compared with atenolol -: The Losartan Intervention for Endpoint Reduction in Hypertension (LIFE) trial [J].
Devereux, RB ;
Dahlöf, B ;
Gerdts, E ;
Boman, K ;
Nieminen, MS ;
Papademetriou, V ;
Rokkedal, J ;
Harris, KE ;
Edelman, JM ;
Wachtell, K .
CIRCULATION, 2004, 110 (11) :1456-1462
[3]   STANDARDIZATION OF M-MODE ECHOCARDIOGRAPHIC LEFT-VENTRICULAR ANATOMIC MEASUREMENTS [J].
DEVEREUX, RB ;
LUTAS, EM ;
CASALE, PN ;
KLIGFIELD, P ;
EISENBERG, RR ;
HAMMOND, IW ;
MILLER, DH ;
REIS, G ;
ALDERMAN, MH ;
LARAGH, JH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (06) :1222-1230
[4]   The Edwards MIRA™ heart valve prosthesis:: A 2-year study [J].
Driever, R ;
Fuchs, S ;
Meissner, M ;
Schmitz, E ;
Vetter, HO .
JOURNAL OF CARDIAC SURGERY, 2004, 19 (03) :226-231
[5]   Recommendations for a standardized report for adult transthoracic echocardiography: A report from the American society of Echocardiography's nomenclature and standards committee and task force for a standardized Echocardiography report [J].
Gardin, JM ;
Adams, DB ;
Douglas, PS ;
Feigenbaum, H ;
Forst, DH ;
Fraser, AG ;
Grayburn, PA ;
Katz, AS ;
Keller, AM ;
Kerber, RE ;
Khandheria, BK ;
Klein, AL ;
Lang, RM ;
Pierard, LA ;
Quinones, MA ;
Schnittger, I .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (03) :275-290
[6]   The heart in the hypertensive elderly [J].
Grodzicki, T ;
Messerli, FH .
JOURNAL OF HUMAN HYPERTENSION, 1998, 12 (09) :593-597
[7]   Patient prosthesis mismatch is rare after aortic valve replacement: Valve size may be irrelevant - Discussion [J].
Olinger, GN ;
Christakis, GT .
ANNALS OF THORACIC SURGERY, 2002, 73 (06) :1829-1829
[8]   Determinants of incomplete left ventricular mass regression following aortic valve replacement for aortic stenosis [J].
Hanayama, N ;
Christakis, GT ;
Mallidi, HR ;
Rao, V ;
Cohen, G ;
Goldman, BS ;
Fremes, SE ;
Morgan, CD ;
Joyner, CD .
JOURNAL OF CARDIAC SURGERY, 2005, 20 (04) :307-313
[9]   FIBRILLAR COLLAGEN AND MYOCARDIAL STIFFNESS IN THE INTACT HYPERTROPHIED RAT LEFT-VENTRICLE [J].
JALIL, JE ;
DOERING, CW ;
JANICKI, JS ;
PICK, R ;
SHROFF, SG ;
WEBER, KT .
CIRCULATION RESEARCH, 1989, 64 (06) :1041-1050
[10]   Effects of valve substitute on changes in left ventricular function and hypertrophy after aortic valve replacement [J].
Jin, XY ;
Zhang, ZM ;
Gibson, DG ;
Yacoub, MH ;
Pepper, JR .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :683-690