Comparison of MTBSTFA and BSTFA in derivatization reactions of polar compounds prior to GC/MS analysis

被引:236
|
作者
Schummer, Claude [1 ,2 ]
Delhomme, Olivier [1 ]
Appenzeller, Brice M. R. [2 ]
Wennig, Robert [2 ]
Millet, Maurice [1 ]
机构
[1] Univ Strasbourg, CNRS, Ctr Geochim Surface, Physicochim Atmosphere Lab, F-67084 Strasbourg, France
[2] Univ Luxembourg, Ctr Rech Publ Sante, Lab Natl Sante, Toxicol Lab, L-1511 Luxembourg, Luxembourg
关键词
MTBSTFA; BSTFA; Derivatization; Silylation; CHROMATOGRAPHY-MASS-SPECTROMETRY; SOLID-PHASE EXTRACTION; GC-MS; METABOLITES; DERIVATIVES; MATRICES; QUANTIFICATION; IDENTIFICATION; NITROPHENOLS; ATMOSPHERE;
D O I
10.1016/j.talanta.2008.09.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, MTBSTFA and BSTFA, which are among the preferred derivatization reagents for silylation were both tested on derivatization of six different groups of polar chemicals to get information about usefulness in terms or sensitivity and specificity of both reagents, Tested compound groups were nitrophenols and methoxyphenols. sterols and sugars, dicarboxylic acids and hydroxylated polycyclic aromatic hydrocarbons. It Was found that MTBSTFA-derivates produce characteristic fragmentation patterns presenting mainly the fragments [M](+), [M-57](+) and [M-131](+), of which [M-57](+) is generally dominant on the mass spectrogram. BSTFA-derivates mainly show the fragments [M](+), [M-15](+) and [M-89](+) whereof the molecular ion [M](+) is generally dominant. It was also found that steric hindrance and molecular mass play a very important role in the choice of the best suited derivatization reagent: compounds with sterically hindered sites derivatized with MTBSTFA produce very small analytical responses or no signal at all, and compounds with high molecular mass produce no characteristic fragmentation pattern when derivatization is performed with BSTFA. It was also found that MTBSTFA-derivatization facilitates separation of isomer analytes, suggesting its choice in combination to semi-polar columns, whilst BSTFA seems better for sterically hindered compounds. Findings were confirmed with applications of both reagents to biological and environmental matrices (urine and atmospheric aerosols). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1473 / 1482
页数:10
相关论文
共 50 条
  • [31] LC-ESI/MS/MS analysis with derivatization applied to polar disinfection by-products in water treatment
    Zwiener, C
    Glauner, T
    Frimmel, FH
    3RD WORLD WATER CONGRESS: WATER SERVICES MANAGEMENT, OPERATIONS AND MONITORING, 2003, 3 (1-2): : 321 - 328
  • [32] Chemical derivatization for the analysis of drugs by GC-MS - A conceptual review
    Lin, Dong-Liang
    Wang, Sheng-Meng
    Wu, Chih-Hung
    Chen, Bud-Gen
    Lu, Ray H.
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2008, 16 (01) : 1 - 10
  • [33] Simultaneous analysis of polar and non-polar components of cell membrane phospholipids by GC-MS
    Bierhanzl, Vaclav M.
    Bursova, Miroslava
    Ston, Martin
    Cabala, Radomir
    Seydlova, Gabriela
    CHEMICAL PAPERS, 2016, 70 (10) : 1309 - 1315
  • [34] GC-MS analysis of organic acids in human urine in clinical settings: A study of derivatization and other analytical parameters
    Christou, Chrysoula
    Gika, Helen. G.
    Raikos, Nikolaos
    Theodoridis, Georgios
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 964 : 195 - 201
  • [35] Analysis of fluoxetine and norfluoxetine in human plasma by liquid-phase microextraction and injection port derivatization GC-MS
    Felicioni Oliveira, Antonio Felipe
    de Figueiredo, Eduardo Costa
    dos Santos-Neto, Alvaro Jose
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 73 : 53 - 58
  • [36] Simultaneous analysis of polar and non-polar components of cell membrane phospholipids by GC-MS
    Václav M. Bierhanzl
    Miroslava Bursová
    Martin Ston
    Radomír Ĉabala
    Gabriela Seydlová
    Chemical Papers, 2016, 70 : 1309 - 1315
  • [37] Comparison of enzymatic and GC-MS/MS analysis of creatinine in urine samples
    Ferenczy, Viktoria
    Kotora, Peter
    Hudecova, Dusana
    Blasko, Jaroslav
    Kubinec, Robert
    Behulova, Darina
    PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY", 2015, : 7 - 11
  • [38] Analysis of Scopoletin and Caffeic Acid in Tobacco by GC-MS After a Rapid Derivatization Procedure
    Li, Fujuan
    Liu, Qian
    Cai, Wensheng
    Shao, Xueguang
    CHROMATOGRAPHIA, 2009, 69 (7-8) : 743 - 748
  • [39] Pentafluoropropionic Anhydride Derivatization and GC-MS Analysis of Histamine, Agmatine, Putrescine, and Spermidine: Effects of Solvents and Starting Column Temperature
    Tsikas, Dimitrios
    Beckmann, Bibiana
    Baskal, Svetlana
    Brunner, Gorig
    MOLECULES, 2023, 28 (03):
  • [40] Comparison of silylation and esterification/acylation procedures in GC-MS analysis of amino acids
    Sobolevsky, TG
    Revelsky, AI
    Miller, B
    Oriedo, V
    Chernetsova, ES
    Revelsky, IA
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (17): : 1474 - 1478