Effectiveness of Impact Echo testing in detecting flaws in prestressed concrete slabs

被引:35
作者
Chaudhary, Muhammad Tariq A. [1 ]
机构
[1] Al Imam Mohammad Ibn Saud Islamic Univ, Riyadh 11681, Saudi Arabia
关键词
Non-Destructive Testing; Post-tensioned concrete slab; Impact Echo method; Resonant frequency; Geometric correction factor; Reliability; NDT METHODS;
D O I
10.1016/j.conbuildmat.2013.05.021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents application of Impact Echo (lE) technique for evaluation of unsound concrete in the anchorage zones of a post-tensioned (PT) slab in a high rise building. The L-shaped area where the problem occurred was located at the interface of prestressed concrete beams and a depressed floor slab. Single point IE evaluation was used as the Non-Destructive Testing (NDT) evaluation method due to its portability and recent success in similar applications. Repair scheme for the affected portions was devised based on the results of IE investigations. Majority (84%) of the tested locations were classified as Good or Fair and required no further investigation/repair. The remaining 16% of the locations that were identified as Questionable or Poor by IE testing were manually investigated by field chipping. These destructive field investigations revealed that the accuracy of fault prediction by single point IE method in the current application was around 60% for the points that were classified as Questionable/Poor. Adjustment to the commonly used geometric correction factor (K) in IE testing by +/- 5% improved this accuracy to 81%. This finding points to the need of adopting a revised geometric correction factor in IE testing of actual structural elements under field conditions. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:753 / 759
页数:7
相关论文
共 23 条
[1]   Evaluation of grouting in tunnel lining using impact-echo [J].
Aggelis, D. G. ;
Shiotani, T. ;
Kasai, K. .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2008, 23 (06) :629-637
[2]  
American Concrete Institute (ACI), 2010, 117M10 ACI
[3]  
[Anonymous], 1997, Impact-echo, Non-destructive evaluation of concrete and masonry
[4]  
[Anonymous], 2004, C1383 ASTM, V04.02
[5]  
[Anonymous], 2004, 2282R98 ACI
[6]   Comparative performance tests and validation of NDT methods for concrete testing [J].
Beutel, Ralf ;
Reinhardt, Hans-Wolf ;
Grosse, Christian U. ;
Glaubitt, Andre ;
Krause, Martin ;
Maierhofer, Christiane ;
Algernon, Daniel ;
Wiggenhauser, Herbert ;
Schickert, Martin .
JOURNAL OF NONDESTRUCTIVE EVALUATION, 2008, 27 (1-3) :59-65
[7]   Training: Often the missing link in using NDT methods [J].
Carino, N. J. .
CONSTRUCTION AND BUILDING MATERIALS, 2013, 38 :1316-1329
[8]  
Carino N.J., 2001, P 2001 STRUCTURES C, P1
[9]  
Clausen JS, 2009, 10 ACI INT C REC ADV
[10]  
Gabriella E, 2010, MATER STRUCT, V43, P235