The Respiration Rate Estimation Method based on the Signal Maximums and Minimums Detection and the Signal Amplitude Evaluation

被引:0
|
作者
Lukocius, R. [1 ]
Virbalis, J. A. [1 ]
Daunoras, J. [2 ]
Vegys, A. [3 ]
机构
[1] Kaunas Univ Technol, Dept Theoret Elect Engn, Studentu Str 48, LT-51367 Kaunas, Lithuania
[2] Kaunas Univ Technol, Dept Control Technol, Studentu Str 48, LT-51367 Kaunas, Lithuania
[3] Kaunas Univ Technol, Dept Ergon, Studentu Str 50, LT-51368 Kaunas, Lithuania
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The respiration rate estimation method is developed. The method is based on the signal maximum and minimum values detection and amplitudes evaluation. The high deviations from isoline of the inductance plethysmography sensor signal are caused by the human torso movements. The application of the common filters for the deviations suppression is not acceptable because of the oscillations caused by filters. Detection of signal minimums and maximums is applied in the method. The noise peaks are suppressed by the adaptive moving average filter. The adaptive peak detection window with the variable width is applied for the peak detection. The detected peaks are compared with an adaptive peak threshold. The method is implemented in the C++ language and applied in the system of physiological parameter monitoring. III. 10, bibl. 6 (in English; summaries in English, Russian and Lithuanian).
引用
收藏
页码:51 / 54
页数:4
相关论文
共 50 条
  • [1] An alternative method for the TileCal signal detection and amplitude estimation
    Sotto-Maior Peralva, B.
    14TH INTERNATIONAL WORKSHOP ON ADVANCED COMPUTING AND ANALYSIS TECHNIQUES IN PHYSICS RESEARCH (ACAT 2011), 2012, 368
  • [2] An Objective Evaluation Method of Multifocal Electroretinogram Amplitude Based on Signal Detection Theory
    Souza, G. S.
    de Carvalho, A. C.
    Gomes, B. D.
    Ventura, D. F.
    Silveira, L. C. L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Fourier Analysis Based Respiration Rate Estimation Using Corrupted Photoplethysmogram Signal
    Pankaj
    Kumar, Ashish
    Komaragiri, Rama
    Kumar, Manjeet
    2022 5TH INTERNATIONAL CONFERENCE ON MULTIMEDIA, SIGNAL PROCESSING AND COMMUNICATION TECHNOLOGIES (IMPACT), 2022,
  • [4] Breathing Signal Combining for Respiration Rate Estimation in Smart Beds
    Azimi, H.
    Gilakjani, S. Soleimani
    Bouchard, M.
    Bennett, S.
    Goubran, R. A.
    Knoefel, F.
    2017 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2017, : 303 - 307
  • [5] A Mode 5 Signal Detection Method Based on Phase and Amplitude Correlation
    Guo, Yang
    Yang, Jianbo
    Guan, Chunjian
    2013 NINTH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION (ICNC), 2013, : 1219 - 1223
  • [6] An amplitude signal based technique for hypopneas detection
    Hernandez-Pereira, E.
    Fernandez-Rey, B.
    Cabrero-Canosa, M.
    Moret-Bonillo, V.
    PROCEDINGS OF THE 11TH IASTED INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND SOFT COMPUTING, 2007, : 127 - 130
  • [7] PPG based Respiration Signal Estimation using VMDPCA
    Ye, Hangyang
    Zhu, Jin
    Cheng, Yongqiang
    Xue, Dongfei
    Wang, Bing
    Peng, Yonghong
    2018 24TH IEEE INTERNATIONAL CONFERENCE ON AUTOMATION AND COMPUTING (ICAC' 18), 2018, : 236 - 240
  • [8] POLYNOMIAL ESTIMATION OF THE AMPLITUDE OF A SIGNAL
    BONDON, P
    IEEE TRANSACTIONS ON INFORMATION THEORY, 1994, 40 (03) : 960 - 965
  • [9] ROBUST ESTIMATION OF SIGNAL AMPLITUDE
    AKIMOV, PS
    LISIJ, VM
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1983, 26 (11): : 25 - 29
  • [10] Research on the Detection Method of MRS Signal Initial Amplitude Based on Chaotic Detection System
    Li, Cong
    Zeng, Zhaofa
    Yi, Xiaofeng
    Wang, Pengyu
    Wang, Yue
    Lu, Kaihua
    Sun, Yong
    An, Baizhou
    IEEE ACCESS, 2023, 11 : 7959 - 7967