Characteristics of highly cross-linked polyethylene wear debris in vivo

被引:30
作者
Baxter, Ryan M. [1 ]
MacDonald, Daniel W. [1 ]
Kurtz, Steven M. [1 ,3 ]
Steinbeck, Marla J. [1 ,2 ]
机构
[1] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[2] Drexel Univ, Coll Drexel Med, Philadelphia, PA 19104 USA
[3] Exponent Inc, Philadelphia, PA USA
关键词
total hip replacementhighly cross-linked polyethyleneosteolysiswear debrisbiological activity; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL HIP-ARTHROPLASTY; FUNCTIONAL BIOLOGICAL-ACTIVITY; CONVENTIONAL POLYETHYLENE; UHMWPE PARTICLES; PERIPROSTHETIC TISSUE; MECHANICAL-PROPERTIES; 5-YEAR EXPERIENCE; GAMMA-RADIATION; EARLY FAILURE;
D O I
10.1002/jbm.b.32902
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Despite the widespread implementation of highly cross-linked polyethylene (HXLPE) liners to reduce the clinical incidence of osteolysis, it is not known if the improved wear resistance will outweigh the inflammatory potential of HXLPE wear debris generated in vivo. Thus, we asked: What are the differences in size, shape, number, and biological activity of polyethylene wear particles obtained from primary total hip arthroplasty revision surgery of conventional polyethylene (CPE) versus remelted or annealed HXLPE liners? Pseudocapsular tissue samples were collected from revision surgery of CPE and HXLPE (annealed and remelted) liners, and digested using nitric acid. The isolated polyethylene wear particles were evaluated using scanning electron microscopy. Tissues from both HXLPE cohorts contained an increased percentage of submicron particles compared to the CPE cohort. However, the total number of particles was lower for both HXLPE cohorts, as a result there was no significant difference in the volume fraction distribution and specific biological activity (SBA; the relative biological activity per unit volume) between cohorts. In contrast, based on the decreased size and number of HXLPE wear debris there was a significant decrease in total particle volume (mm3/g of tissue). Accordingly, when the SBA was normalized by total particle volume (mm3/gm tissue) or by component wear volume rate (mm3/year), functional biological activity of the HXLPE wear debris was significantly decreased compared to the CPE cohort. Indications for this study are that the osteolytic potential of wear debris generated by HXLPE liners in vivo is significantly reduced by improvements in polyethylene wear resistance. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 467475, 2013.
引用
收藏
页码:467 / 475
页数:9
相关论文
共 74 条
[61]  
2-H
[62]   Retrieved Highly Crosslinked UHMWPE Acetabular Liners Have Similar Wear Damage as Conventional UHMWPE [J].
Schroder, David T. ;
Kelly, Natalie H. ;
Wright, Timothy M. ;
Parks, Michael L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :387-394
[63]   Particle analysis for the determination of UHMWPE wear [J].
Scott, M ;
Morrison, M ;
Mishra, SR ;
Jani, S .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 73B (02) :325-337
[64]   Do current wear particle isolation procedures underestimate the number of particles generated by prosthetic bearing components? [J].
Scott, M ;
Widding, K ;
Jani, S .
WEAR, 2001, 251 :1213-1217
[65]   Reduction of wear volume from ultrahigh molecular weight polyethylene knee components by the addition of vitamin E [J].
Teramura, Satoshi ;
Sakoda, Hideyuki ;
Terao, Tomohiro ;
Endo, Miguel M. ;
Fuiiwara, Kunihiko ;
Tomita, Naohide .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (04) :460-464
[66]  
Tipper JL, 2009, BIOL RESPONSE NANOME
[67]   Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty [J].
Tower, Stephen S. ;
Currier, John H. ;
Currier, Barbara H. ;
Lyford, Kimberly A. ;
Van Citters, Douglas W. ;
Mayor, Michael B. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (10) :2212-2217
[68]   Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement [J].
Urban, RM ;
Jacobs, JJ ;
Tomlinson, MJ ;
Gavrilovic, J ;
Black, J ;
Peoc'h, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :457-477
[69]   Influence of design and bearing material on polyethylene wear particle generation in total knee replacement [J].
Utzschneider, S. ;
Paulus, A. ;
Datz, J. -C. ;
Schroeder, C. ;
Sievers, B. ;
Wegener, B. ;
Jansson, V. .
ACTA BIOMATERIALIA, 2009, 5 (07) :2495-2502
[70]   A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding [J].
Wang, A .
WEAR, 2001, 248 (1-2) :38-47