Characteristics of highly cross-linked polyethylene wear debris in vivo

被引:29
作者
Baxter, Ryan M. [1 ]
MacDonald, Daniel W. [1 ]
Kurtz, Steven M. [1 ,3 ]
Steinbeck, Marla J. [1 ,2 ]
机构
[1] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[2] Drexel Univ, Coll Drexel Med, Philadelphia, PA 19104 USA
[3] Exponent Inc, Philadelphia, PA USA
关键词
total hip replacementhighly cross-linked polyethyleneosteolysiswear debrisbiological activity; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL HIP-ARTHROPLASTY; FUNCTIONAL BIOLOGICAL-ACTIVITY; CONVENTIONAL POLYETHYLENE; UHMWPE PARTICLES; PERIPROSTHETIC TISSUE; MECHANICAL-PROPERTIES; 5-YEAR EXPERIENCE; GAMMA-RADIATION; EARLY FAILURE;
D O I
10.1002/jbm.b.32902
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Despite the widespread implementation of highly cross-linked polyethylene (HXLPE) liners to reduce the clinical incidence of osteolysis, it is not known if the improved wear resistance will outweigh the inflammatory potential of HXLPE wear debris generated in vivo. Thus, we asked: What are the differences in size, shape, number, and biological activity of polyethylene wear particles obtained from primary total hip arthroplasty revision surgery of conventional polyethylene (CPE) versus remelted or annealed HXLPE liners? Pseudocapsular tissue samples were collected from revision surgery of CPE and HXLPE (annealed and remelted) liners, and digested using nitric acid. The isolated polyethylene wear particles were evaluated using scanning electron microscopy. Tissues from both HXLPE cohorts contained an increased percentage of submicron particles compared to the CPE cohort. However, the total number of particles was lower for both HXLPE cohorts, as a result there was no significant difference in the volume fraction distribution and specific biological activity (SBA; the relative biological activity per unit volume) between cohorts. In contrast, based on the decreased size and number of HXLPE wear debris there was a significant decrease in total particle volume (mm3/g of tissue). Accordingly, when the SBA was normalized by total particle volume (mm3/gm tissue) or by component wear volume rate (mm3/year), functional biological activity of the HXLPE wear debris was significantly decreased compared to the CPE cohort. Indications for this study are that the osteolytic potential of wear debris generated by HXLPE liners in vivo is significantly reduced by improvements in polyethylene wear resistance. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 467475, 2013.
引用
收藏
页码:467 / 475
页数:9
相关论文
共 74 条
[11]   5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets -: Two randomized studies using radiostereometric analysis [J].
Digas, Georgios ;
Karrholm, Johan ;
Thanner, Jonas ;
Herberts, Peter .
ACTA ORTHOPAEDICA, 2007, 78 (06) :746-754
[12]   Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses [J].
Endo, M ;
Tipper, JL ;
Barton, DC ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H2) :111-122
[13]  
Endo MM, 2001, BIO-MED MATER ENG, V11, P23
[14]   A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners [J].
Engh, C. Anderson, Jr. ;
Stepniewski, Adam S. ;
Ginn, Stuart D. ;
Beykirch, Sarah E. ;
Sychterz-Terefenko, Christi J. ;
Hopper, Robert H., Jr. ;
Engh, Charles A. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (06) :17-25
[15]  
Ferroni D, 2010, J APPL BIOMATER BIOM, V8, P82
[16]   A novel method for the prediction of functional biological activity of polyethylene wear debris [J].
Fisher, J ;
Bell, J ;
Barbour, PSM ;
Tipper, JL ;
Matthews, JB ;
Besong, AA ;
Stone, MH ;
Ingham, E .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H2) :127-132
[17]   Clinical fracture of cross-linked UHMWPE acetabular liners [J].
Furmanski, Jevan ;
Anderson, Martin ;
Bal, Sonny ;
Greenwald, A. Seth ;
Halley, David ;
Penenberg, Brad ;
Ries, Michael ;
Pruitt, Lisa .
BIOMATERIALS, 2009, 30 (29) :5572-5582
[18]   The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty [J].
Gallo, Jiri ;
Slouf, Miroslav ;
Goodman, Stuart B. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 94B (01) :171-177
[19]   Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations [J].
Galvin, A. L. ;
Tipper, I. L. ;
Jennings, L. M. ;
Stone, M. H. ;
Jin, Z. M. ;
Ingham, E. ;
Fisher, J. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H1) :1-10
[20]   Crosslinked polyethylene compared to conventional polyethylene in total hip replacement - Pre-clinical evaluation, in-vitro testing and prospective clinical follow-up study [J].
Geerdink, Carel H. ;
Grimm, Bernd ;
Ramakrishnan, Rama ;
Rondhuis, Jorco ;
Verburg, Aart J. ;
Tonino, Alphons J. .
ACTA ORTHOPAEDICA, 2006, 77 (05) :719-725