Conventional X-ray transmission radiography has long been used for online detection of foreign bodies in food products relying on the absorption contrast between the foreign body and food product. In this paper, we present a novel approach for detection of organic foreign bodies such as paper and insects in two food products using X-ray dark-field imaging with a grating interferometer. The ability to detect the foreign bodies is quantified using a measure of the contrast-to-noise ratio. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [1] Preclinical X-ray dark-field imaging: foreign body detection
    Braig, Eva-Maria
    Muenzel, Daniela
    Fingerle, Alexander
    Herzen, Julia
    Rummeny, Ernst
    Pfeiffer, Franz
    Noer, Peter
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [2] Improved Detection of Foreign Bodies on Radiographs Using X-ray Dark-Field and Phase-Contrast Imaging
    Hellbach, Katharina
    Beller, Ebba
    Schindler, Andreas
    Schoeppe, Franziska
    Hesse, Nina
    Baumann, Alena
    Schinner, Regina
    Auweter, Sigrid
    Hauke, Christian
    Radicke, Marcus
    Meinel, Felix G.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (06) : 352 - 356
  • [3] Energy weighted x-ray dark-field imaging
    Pelzer, Georg
    Zang, Andrea
    Anton, Gisela
    Bayer, Florian
    Horn, Florian
    Kraus, Manuel
    Rieger, Jens
    Ritter, Andre
    Wandner, Johannes
    Weber, Thomas
    Fauler, Alex
    Fiederle, Michael
    Wong, Winnie S.
    Campbell, Michael
    Meiser, Jan
    Meyer, Pascal
    Mohr, Juergen
    Michel, Thilo
    OPTICS EXPRESS, 2014, 22 (20): : 24507 - 24515
  • [4] Dynamic In Vivo Chest X-ray Dark-Field Imaging in Mice
    Gradl, R.
    Morgan, K. S.
    Dierolf, M.
    Jud, C.
    Hehn, L.
    Guenther, B.
    Moeller, W.
    Kutschke, D.
    Yang, L.
    Stoeger, T.
    Pfeiffer, D.
    Gleich, B.
    Achterhold, K.
    Schmid, O.
    Pfeiffer, F.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (02) : 649 - 656
  • [5] X-ray Dark-Field Imaging for Improved Contrast in Historical Handwritten Literature
    Akstaller, Bernhard
    Schreiner, Stephan
    Dietrich, Lisa
    Rauch, Constantin
    Schuster, Max
    Ludwig, Veronika
    Hofmann-Randall, Christina
    Michel, Thilo
    Anton, Gisela
    Funk, Stefan
    JOURNAL OF IMAGING, 2022, 8 (09)
  • [6] Frozen and defrosted fruit revealed with X-ray dark-field radiography
    Nielsen, Mikkel Schou
    Christensen, Lars Bager
    Feidenhans'l, Robert
    FOOD CONTROL, 2014, 39 : 222 - 226
  • [7] On detailed contrast of biomedical object in X-ray dark-field imaging
    Shimao, Daisuke
    Sugiyama, Hiroshi
    Kunisada, Toshiyuki
    Hyodo, Kazuyuki
    Mori, Koichi
    Ando, Masami
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1960 - +
  • [8] Development of X-ray dark-field imaging towards clinical application
    ANDO Masami
    HASHIMOTO Eiko
    HASHIZUME Hiroyuki
    HYODO Kazuyuki
    INOUE Hajime
    ISHIKAWA Tetsuya
    KUNISADA Toshiyuki
    MAKSIMENKO Anton
    PATTANASIRIWISAWA Wanwisa
    RUBENSTEIN Edward
    ROBERSON Joseph
    SHIMAO Daisuke
    SUGIYAMA Hiroshi
    TAKEDA Ken
    UENO Ei
    WADA Hiroshi
    Nuclear Science and Techniques, 2004, (03) : 129 - 139
  • [9] X-ray Dark-Field Imaging and potential of its clinical application
    Shimao, D
    Sugiyama, H
    Kunisada, T
    Maksimenko, A
    Toyofuku, F
    Ueno, E
    Yamasaki, K
    Obayashi, C
    Hyodo, K
    Li, G
    Pan, L
    Jiang, XM
    Ando, M
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 32 - 39
  • [10] A new optics for dark-field imaging in X-ray region 'Owl'
    Ando, M
    Sugiyama, H
    Maksimenko, A
    Pattanasiriwisawa, W
    Hyodo, K
    Zhang, XW
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2001, 40 (8A): : L844 - L846