Comprehensive two-dimensional gas chromatography (GC x GC) retention time shift correction and modeling using bilinear peak alignment, correlation optimized shifting and multivariate curve resolution

被引:43
|
作者
Parastar, Hadi [1 ,2 ]
Jalali-Heravi, Mehdi [2 ]
Tauler, Roma [3 ]
机构
[1] Univ Isfahan, Fac Sci, Dept Chem, Esfahan 8174673441, Iran
[2] Sharif Univ Technol, Dept Chem, Tehran, Iran
[3] IDAEA CSIC, Dept Environm Chem, Barcelona 08034, Spain
关键词
Comprehensive two-dimensional gas chromatography; Retention time shift; Peak alignment; Multivariate curve resolution-alternating least squares; Bilinear peak alignment; CHEMOMETRIC ANALYSIS; QUANTITATIVE-ANALYSIS; BAND BOUNDARIES; PART II; ALGORITHM; SEPARATIONS; PROFILES; PARAFAC2; RANK;
D O I
10.1016/j.chemolab.2012.02.003
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A combination of peak alignment methods and multivariate curve resolution (MCR) is proposed for handling retention time shifts and modeling of comprehensive two-dimensional gas chromatographic (GC x GC) data in the case of univariate detection systems such as in flame ionization detection (FID) or in total ion current mass spectrometry (TIC-MS) detection. A new bilinear peak alignment (BPA) method, based on MCR, is first proposed to correct for progressive within run retention time shifts in GC x GC due to temperature programming effects on second chromatographic dimension. The performance of the proposed peak alignment method is compared to that of the correlation optimized warping (COW) method. In addition, Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) method, under proper constraints, is also proposed to analyze the augmented GC x GC data matrix for the resolution and quantification of target compounds in complex samples when incomplete separation and co-elution problems exist. For those difficult cases in which large between GC x GC run retention time shifts exist in both dimensions, a preliminary between runs first dimension peak alignment method by Correlation Optimized Shifting (COShift) is used to preserve the bilinearity model assumption needed for MCR-ALS application. The results showed the successful application of the proposed strategy for resolution and quantification of some target compounds in GC x GC analysis of simulated and of real samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 91
页数:12
相关论文
共 50 条
  • [21] Optimization of comprehensive two-dimensional gas-chromatography (GC x GC) mass spectrometry for the determination of essential oils
    Omar, Jone
    Alonso, Bone
    Olivares, Maitane
    Vallejo, Asier
    Etxebarria, Nestor
    TALANTA, 2012, 88 : 145 - 151
  • [22] Comprehensive two-dimensional gas chromatography with mass spectrometric detection (GC x GC/MS) applied to the analysis of petroleum
    Frysinger, GS
    Gaines, RB
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (05): : 251 - 255
  • [23] Characterization of the volatile compounds of huangjiu using comprehensive two-dimensional gas chromatography coupled to time of flight mass spectrometry (GC x GC-TOFMS)
    Zhou, Zhilei
    Ji, Zhongwei
    Liu, Shuangping
    Han, Xiao
    Zheng, Fuping
    Mao, Jian
    JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2019, 43 (10)
  • [24] Comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GC x GC-TOFMS) for drug screening and confirmation
    Song, SM
    Marriott, P
    Kotsos, A
    Drummer, OH
    Wynne, P
    FORENSIC SCIENCE INTERNATIONAL, 2004, 143 (2-3) : 87 - 101
  • [25] Quality evaluation of volatile oils of Traditional Chinese Medicines by using comprehensive two-dimensional gas chromatography (GC×GC)
    Chunhai Ruan
    Guowang Xu
    Xin Lu
    Ruixiang Hua
    Hongwei Kong
    Ke Xiao
    Qing Yang
    Chromatographia, 2003, 57 : S265 - S270
  • [26] Fast comprehensive two-dimensional gas chromatography (GC x GC) using 50-μm ID second-dimension columns
    Adahchour, M
    Tasöz, A
    Beens, J
    Vreuls, RJJ
    Batenburg, AM
    Brinkman, UAT
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) : 753 - 760
  • [27] Single-jet, single-stage cryogenic modulator for comprehensive two-dimensional gas chromatography (GC x GC)
    Adahchour, M
    Beens, J
    Brinkman, UAT
    ANALYST, 2003, 128 (03) : 213 - 216
  • [28] Recent developments in comprehensive two-dimensional gas chromatography (GC X GC) - IV. Further applications, conclusions and perspectives
    Adahchour, M.
    Beens, J.
    Vreuls, R. J. J.
    Brinkman, U. A. Th.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (08) : 821 - 840
  • [29] Comprehensive two-dimensional gas chromatography time of flight mass spectrometry (GC x GC-TOFMS) for environmental forensic investigations in developing countries
    de Vos, Jayne
    Dixon, Roger
    Vermeulen, Gerhard
    Gorst-Allman, Peter
    Cochran, Jack
    Rohwer, Egmont
    Focant, Jean-Francois
    CHEMOSPHERE, 2011, 82 (09) : 1230 - 1239
  • [30] Optimization and characterization of comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection (GC x GC-TOF MS)
    Dallüge, J
    Vreuls, RJJ
    Beens, J
    Brinkman, UAT
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (04) : 201 - 214