Comprehensive two-dimensional gas chromatography (GC x GC) retention time shift correction and modeling using bilinear peak alignment, correlation optimized shifting and multivariate curve resolution

被引:43
|
作者
Parastar, Hadi [1 ,2 ]
Jalali-Heravi, Mehdi [2 ]
Tauler, Roma [3 ]
机构
[1] Univ Isfahan, Fac Sci, Dept Chem, Esfahan 8174673441, Iran
[2] Sharif Univ Technol, Dept Chem, Tehran, Iran
[3] IDAEA CSIC, Dept Environm Chem, Barcelona 08034, Spain
关键词
Comprehensive two-dimensional gas chromatography; Retention time shift; Peak alignment; Multivariate curve resolution-alternating least squares; Bilinear peak alignment; CHEMOMETRIC ANALYSIS; QUANTITATIVE-ANALYSIS; BAND BOUNDARIES; PART II; ALGORITHM; SEPARATIONS; PROFILES; PARAFAC2; RANK;
D O I
10.1016/j.chemolab.2012.02.003
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A combination of peak alignment methods and multivariate curve resolution (MCR) is proposed for handling retention time shifts and modeling of comprehensive two-dimensional gas chromatographic (GC x GC) data in the case of univariate detection systems such as in flame ionization detection (FID) or in total ion current mass spectrometry (TIC-MS) detection. A new bilinear peak alignment (BPA) method, based on MCR, is first proposed to correct for progressive within run retention time shifts in GC x GC due to temperature programming effects on second chromatographic dimension. The performance of the proposed peak alignment method is compared to that of the correlation optimized warping (COW) method. In addition, Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) method, under proper constraints, is also proposed to analyze the augmented GC x GC data matrix for the resolution and quantification of target compounds in complex samples when incomplete separation and co-elution problems exist. For those difficult cases in which large between GC x GC run retention time shifts exist in both dimensions, a preliminary between runs first dimension peak alignment method by Correlation Optimized Shifting (COShift) is used to preserve the bilinearity model assumption needed for MCR-ALS application. The results showed the successful application of the proposed strategy for resolution and quantification of some target compounds in GC x GC analysis of simulated and of real samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 91
页数:12
相关论文
共 50 条
  • [1] COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY (GC x GC)
    Pedroso, Marcio Pozzobon
    Fonseca de Godoy, Luiz Antonio
    de Vasconcellos Fidelis, Carlos Henrique
    Ferreira, Ernesto Correa
    Poppi, Ronei Jesus
    Augusto, Fabio
    QUIMICA NOVA, 2009, 32 (02): : 421 - 430
  • [2] Comprehensive two-dimensional gas chromatography - GC x GC
    Marriott, P
    JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6): : 357 - 357
  • [3] Enhancing the limit of detection for comprehensive two-dimensional gas chromatography (GC x GC) using bilinear chemometric analysis
    Fraga, CG
    Prazen, BJ
    Synovec, RE
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (03): : 215 - 224
  • [4] The evolution of comprehensive two-dimensional gas chromatography (GC x GC)
    Górecki, T
    Harynuk, J
    Panic, O
    JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6) : 359 - 379
  • [5] Comprehensive two-dimensional gas chromatography (GC x GC) as a diagnostic tool
    Beens, J
    Tijssen, R
    Blomberg, J
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (01): : 63 - 64
  • [6] Recent advances in comprehensive two-dimensional gas chromatography (GC x GC)
    Gorecki, Tadeusz
    Panic, Ognjen
    Oldridge, Nathan
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (7-8) : 1077 - 1104
  • [7] Quantitative aspects of comprehensive two-dimensional gas chromatography (GC x GC)
    Beens, J
    Boelens, H
    Tijssen, R
    Blomberg, J
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (01): : 47 - 54
  • [8] A comparison of modulating interface technologies in comprehensive two-dimensional gas chromatography (GC x GC)
    Lee, AL
    Lewis, AC
    Bartle, KD
    McQuaid, JB
    Marriott, PJ
    JOURNAL OF MICROCOLUMN SEPARATIONS, 2000, 12 (04) : 187 - 193
  • [9] Compound class oil fingerprinting techniques using comprehensive two-dimensional gas chromatography (GC x GC)
    Ventura, G. Todd
    Raghuraman, Bhavani
    Nelson, Robert K.
    Mullins, Oliver C.
    Reddy, Christopher M.
    ORGANIC GEOCHEMISTRY, 2010, 41 (09) : 1026 - 1035
  • [10] Comprehensive two-dimensional gas chromatography (GC x GC) and GC x GC-quadrupole MS analysis of Asian and American ginseng
    Shellie, RA
    Marriott, PJ
    Huie, CW
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (12-13) : 1185 - 1192