Cementless large-head metal-on-metal total hip arthroplasty in patients younger than 60 years-A multicenter early result

被引:1
作者
Wu, Po-Ting [1 ,2 ]
Wang, Chih-Jen [3 ]
Yen, Cheng-Yo [4 ]
Jian, Ji-Shen [5 ]
Lai, Kuo-An [1 ]
机构
[1] Natl Cheng Kung Univ Hosp, Dept Orthopaed, Tainan 70428, Taiwan
[2] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 70101, Taiwan
[3] Trust Orthopaed Inst, Tainan, Taiwan
[4] E Da Hosp, Dept Orthopaed, Kaohsiung, Taiwan
[5] Chi Mei Hosp, Dept Orthopaed, Tainan, Taiwan
关键词
Large head; Metal-on-metal; Total hip arthroplasty; Young adults; DIAMETER FEMORAL HEADS; EARLY DISLOCATION RATE; THAN; 50; YEARS; FOLLOW-UP; ACETABULAR COMPONENT; REPLACEMENT PATIENTS; CANCER INCIDENCE; AGE; BEARINGS; CHARNLEY;
D O I
10.1016/j.kjms.2011.06.021
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Large-head metal-on-metal total hip arthroplasty has the theoretical advantages of less wear and better range of motion than traditional polyethylene bearings and seems to be a better choice for young and active patients. We conducted a retrospective study and reported the early results of using such prostheses in 59 patients (70 hips) with a mean age of 43.1 years (range, 23-59 years) at the time of surgery. Osteonecrosis of the femoral head accounted for most diagnoses. Harris Hip Scores and hip range of motion both significantly improved (p <0.001) at an average follow-up of 32.6 months (range, 24-48 months). Only one intraoperative calcar fissure was encountered, and it was fixated by cerclage wiring; there was no infection, dislocation, or osteolysis around either the cup or the stem at the latest follow-up. A postoperative gap in the acetabular component was noted in 24 hips, with a mean depth of 1.11 mm, but this was not correlated with the functional score (p = 0.291). Transient thigh pain, which resolved after 6 months, was observed in six patients but was not related to either the postoperative gap or cup inclination (p = 1.000 and p = 0.664, respectively). All patients resumed their original jobs and recreational activities with little discomfort. Thus far, large-head metal-on-metal total hp arthroplasty has shown excellent early results. The Long-term results and the effects of metal debris and potentially elevated serum metal ion levels require further observation. Copyright (C) 2011, Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:30 / 37
页数:8
相关论文
共 40 条
[31]   Magnetic Resonance Imaging Findings in Painful Metal-On-Metal Hips A Prospective Study [J].
Sabah, Shiraz A. ;
Mitchell, Adam W. M. ;
Henckel, Johann ;
Sandison, Ann ;
Skinner, John A. ;
Hart, Alister J. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (01) :71-76
[32]   Metal ion levels after metal-on-metal Ring total hip replacement -: A 30-year follow-up study [J].
Sauve, P. ;
Mountney, J. ;
Khan, T. ;
De Beer, J. ;
Higgins, B. ;
Grover, M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (05) :586-590
[33]   Analysis of 118 second-generation metal-on-metal retrieved hip implants [J].
Sieber, HP ;
Rieker, CB ;
Köttig, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :46-50
[34]   CHANGES IN TRABECULAR PATTERN OF UPPER END OF FEMUR AS AN INDEX OF OSTEOPOROSIS [J].
SINGH, M ;
NAGRATH, AR ;
MAINI, PS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1970, A 52 (03) :457-&
[35]   Metal-on-metal total hip arthroplasty with large heads may prevent early dislocation [J].
Smith, TM ;
Berend, KR ;
Lombardi, AV ;
Emerson, RH ;
Mallory, TH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :137-142
[36]   Anatomic diameter femoral heads in total hip arthroplasty: A preliminary report [J].
Stuchin, Steven A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A :52-56
[37]   Preoperative Predictors of Returning to Work Following Primary Total Knee Arthroplasty [J].
Styron, Joseph F. ;
Barsoum, Wael K. ;
Smyth, Kathleen A. ;
Singer, Mendel E. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (01) :2-10
[38]   Cancer incidence and causes of death among total hip replacement patients: a review based on Nordic cohorts with a special emphasis on metal-on-metal bearings [J].
Visuri, TI ;
Pukkala, E ;
Pulkkinen, P ;
Paavolainen, P .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :399-407
[39]   The early dislocation rate in primary total hip arthroplasty following the posterior approach with posterior soft-tissue repair [J].
Weeden, SH ;
Paprosky, WG ;
Bowling, JW .
JOURNAL OF ARTHROPLASTY, 2003, 18 (06) :709-713
[40]   Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints - A clinical and histomorphological study [J].
Willert, HG ;
Buchhorn, GH ;
Fayyazi, A ;
Flury, R ;
Windler, M ;
Koster, G ;
Lohmann, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :28-36