From total allowable error via metrological traceability to uncertainty of measurement of the unbiased result

被引:14
作者
Dybkaer, R [1 ]
机构
[1] Copenhagen Hosp Corp, Dept Standardizat Lab Med, HS Kommunehosp, DK-1399 Copenhagen K, Denmark
关键词
metrological traceability; total allowable error; trueness; unbiased result; uncertainty of measurement;
D O I
10.1007/s007690050395
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The concept of "total allowable error", investigated by Westgard and co-workers over a quarter of a century for use in laboratory medicine, comprises bias as well as random elements. Yet, to minimize diagnostic misclassifications, it is necessary to have spatio-temporal comparability of results. This requires trueness obtained through metrological traceability based on a calibration hierarchy. Hereby, the result is associated with a final uncertainty of measurement purged of known biases of procedure and laboratory. The sources of bias are discussed and the importance of commutability of calibrators and analytical specificity of the measurement procedure is stressed. The practicability of traceability to various levels and the advantages of the GUM approach for estimating uncertainty are shown.
引用
收藏
页码:401 / 405
页数:5
相关论文
共 33 条
[21]   INFLUENCE OF ANALYTICAL QUALITY AND PREANALYTICAL VARIATIONS ON MEASUREMENTS OF CHOLESTEROL IN SCREENING PROGRAMS [J].
PETERSEN, PH ;
LARSEN, ML ;
HORDER, M ;
BLAABJERG, O .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 :66-72
[22]   INFLUENCE OF ANALYTICAL QUALITY ON TEST-RESULTS [J].
PETERSEN, PH ;
HORDER, M .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1992, 52 :65-87
[23]   The influence of analytical bias on diagnostic misclassifications [J].
Petersen, PH ;
deVerdier, CH ;
Groth, T ;
Fraser, CG ;
Blaabjerg, O ;
Horder, M .
CLINICA CHIMICA ACTA, 1997, 260 (02) :189-206
[24]   ANALYTICAL GOALS FOR THE ESTIMATION OF NON-GAUSSIAN REFERENCE INTERVALS [J].
PETERSEN, PH ;
GOWANS, EMS ;
BLAABJERG, O ;
HORDER, M .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1989, 49 (08) :727-737
[25]   Primary methods of measurement and primary standards [J].
Quinn, TJ .
METROLOGIA, 1997, 34 (01) :61-65
[26]  
STAMM D, 1982, J CLIN CHEM CLIN BIO, V20, P817
[27]  
Taylor B.N., 1994, 1297 NIST, DOI [10.6028/NIST.TN.1297, DOI 10.6028/NIST.TN.1297]
[28]  
WESTGARD JO, 1974, CLIN CHEM, V20, P825
[29]  
WESTGARD JO, 1973, CLIN CHEM, V19, P49
[30]   QC Validator(R) 2.0: A computer program for automatic selection of statistical QC procedures for applications in healthcare laboratories [J].
Westgard, JO ;
Stein, B ;
Westgard, SA ;
Kennedy, R .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1997, 53 (03) :175-186