Evaluation of Temperature-Responsive Open Tubular Capillary Electrochromatographic Column Modified with Poly(N-isopropylacrylamide)

被引:14
作者
Liu, Zongjian [1 ]
Geng, Fangfang [1 ]
Ha, Xuefeng [1 ]
Feng, Yusi [1 ]
Che, Baoquan [2 ]
Wu, Kechun [2 ]
Li, Yujuan [1 ]
Dai, Rongji [1 ]
Zhang, Yukui [1 ]
Deng, Yulin [1 ]
机构
[1] Beijing Inst Technol, Sch Life Sci, Beijing 100081, Peoples R China
[2] Beijing Inst Drug Control, Dept Chem, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Capillary electrochromatography; Poly(N-isopropylacrylamide); Separation; Temperature-responsive polymer; STATIONARY-PHASE; SEPARATION; CHROMATOGRAPHY; PEPTIDES;
D O I
10.1007/s10337-012-2383-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have recently reported the new concept of temperature-responsive capillary electrochromatography (CEC) using a poly(N-isopropylacrylamide)-grafted capillary column. In this study, temperature-responsive CEC separation of six clinical drugs including thymopentin and octreotide acetate (two peptides), homatropinum and oxazepam, benazepril hydrochloridec and amlodipine acetate was conducted to evaluate the separation efficiency of the CEC column. For comparison purposes, a bare capillary column was used for the control experiments. It was found that the resolutions and migration times of thymopentin and octreotide acetate, homatropinum and oxazepam on the modified column were much larger than those on the bare column. Enhanced resolving power mainly resulted from the interactions between analytes and PNIPAAm-grafted capillary surfaces. Therefore, the modification with temperature-responsive PNIPAAm was evaluated to achieve a better separation of the four analytes. The resolutions of benazepril hydrochloridec and amlodipine acetate on the modified column were smaller than those on the bare column because peak broadening and tailing were also obtained, although the differences in migration time between them were much larger. Furthermore, significant changes in the resolution and migration time were only observed on the modified column around the lower critical solution temperature of PNIPAAm, demonstrating its temperature-responsive property.
引用
收藏
页码:201 / 206
页数:6
相关论文
共 23 条
[1]   Polymer Monoliths with Exchangeable Chemistries: Use of Gold Nanoparticles As Intermediate Ligands for Capillary Columns with Varying Surface Functionalities [J].
Cao, Qing ;
Xu, Yan ;
Liu, Feng ;
Svec, Frantisek ;
Frechet, Jean M. J. .
ANALYTICAL CHEMISTRY, 2010, 82 (17) :7416-7421
[2]   Analysis of urinary drugs of abuse by a multianalyte capillary electrophoretic immunoassay [J].
Caslavska, J ;
Allemann, D ;
Thormann, W .
JOURNAL OF CHROMATOGRAPHY A, 1999, 838 (1-2) :197-211
[3]   Direct synthesis of thermally responsive DMA/NIPAM diblock and DMA/NIPAM/DMA triblock copolymers via aqueous, room temperature RAFT polymerization [J].
Convertine, AJ ;
Lokitz, BS ;
Vasileva, Y ;
Myrick, LJ ;
Scales, CW ;
Lowe, AB ;
McCormick, CL .
MACROMOLECULES, 2006, 39 (05) :1724-1730
[4]   Preparation and Characterization of Temperature-Responsive Chromatographic Column Containing Poly(N-isopropylacrylamide) and Poly([2-(methacryloyloxy)ethyl]trimetylammonium chloride) [J].
Dai, Rongji ;
Chen, Lei ;
Liu, Zongjian ;
Wang, Haihui ;
Hu, Dingyu ;
Deng, Yulin .
JOURNAL OF APPLIED POLYMER SCIENCE, 2011, 121 (04) :2233-2238
[5]   Preparation and characterization of temperature-responsive capillary electrochromatographic column using poly(N-isopropylacrylamide) [J].
Dai, Rongji ;
Zhang, Xuejing ;
Hu, Na ;
Liu, Yueying ;
Deng, Yulin .
ELECTROPHORESIS, 2009, 30 (04) :616-617
[6]   A mesoporous silica nanoparticles immobilized open-tubular capillary column with a coating of cellulose tris(3,5-dimethylphenyl-carbamate) for enantioseparation in CEC [J].
Dong, Xiaoli ;
Wu, Ren'an ;
Dong, Jing ;
Wu, Minghuo ;
Zhu, Yan ;
Zou, Hanfa .
ELECTROPHORESIS, 2008, 29 (18) :3933-3940
[7]   Photo-, thermally, and pH-responsive microgels [J].
Garcia, Antonio ;
Marquez, Manuel ;
Cai, Tong ;
Rosario, Rohit ;
Hu, Zhibing ;
Gust, Devens ;
Hayes, Mark ;
Vail, Sean A. ;
Park, Choong-Do .
LANGMUIR, 2007, 23 (01) :224-229
[8]   Comparison of behavior of N-substituted acrylamides and celluloses on double-stranded DNA separations by capillary electrophoresis at 25 degrees and 60 degrees C [J].
Gelfi, C ;
Perego, M ;
Libbra, F ;
Righetti, PG .
ELECTROPHORESIS, 1996, 17 (08) :1342-1347
[9]   Sol-gel open tubular ODS columns with reversed eleotroosmotic flow for capillary electrochromatography [J].
Hayes, JD ;
Malik, A .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :987-996
[10]  
Heskins M., 1968, J Macromol Sci Chem A, V2, P1441, DOI [DOI 10.1080/10601326808051910, 10.1080/10601326808051910]