Pressure drop increase of forced convective condensation inside horizontal coiled wire inserted tubes

被引:26
作者
Akhavan-Behabadi, M. A. [1 ]
Salimpour, M. R. [2 ]
Pazouki, V. A. [1 ]
机构
[1] Univ Tehran, Fac Engn, Dept Mech Engn, Tehran, Iran
[2] Isfahan Univ Technol, Dept Mech Engn, Esfahan 8415683111, Iran
关键词
pressure drop; coiled wire; R-134a; condensation; empirical correlation;
D O I
10.1016/j.icheatmasstransfer.2008.06.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study was performed to investigate the increment of the pressure drop during condensation of R-134 a vapor inside a horizontal tube with different coiled wire inserts. A double-pipe counter-flow heat exchanger of 1040-mm length was used as the test condenser while, the refrigerant flowed inside the inner tube and the coolant flowed in the annulus. Four coiled wires of 10.0-mm pitch and different diameters of 0.5, 0.7, 1.0 and 1.5-mm and also four springs of 1.0-mm diameter and different pitches of 5, 8, 10 and 13-mm were inserted on the refrigerant side of the test condenser. Data were recorded for different mass flow rates in plain tube and each coiled wire inserted tube. Investigating the results for the coiled wire inserted tubes revealed that inserting the springs increased the pressure drop in a range of 260 to 1600% in comparison with that for a plain tube. Also, influence of coiled wire geometry on the pressure drop was investigated. Based on the collected data, an empirical correlation was developed to predict the pressure drop during the condensation inside a horizontal tube in the presence of a spring insert. Finally, the performance evaluation of the coiled wire inserted condensers was done. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1220 / 1226
页数:7
相关论文
共 15 条
[1]   EXPERIMENTAL-STUDY OF HEAT-TRANSFER AUGMENTATION VERSUS PUMPING POWER IN A HORIZONTAL R12 EVAPORATOR [J].
AGRAWAL, KN ;
VARMA, HK .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1991, 14 (05) :273-281
[2]   Augmentation of forced convection condensation heat transfer inside a horizontal tube using spiral spring inserts [J].
Akhavan-Behabadi, MA ;
Salimpoor, MR ;
Kumar, R ;
Agrawal, KN .
JOURNAL OF ENHANCED HEAT TRANSFER, 2005, 12 (04) :373-384
[3]   Enhancement of heat transfer rates by coiled wires during forced convective condensation of R-22 inside horizontal tubes [J].
Akhavan-Behabadi, MA ;
Varma, HK ;
Agarwal, KN .
JOURNAL OF ENHANCED HEAT TRANSFER, 2000, 7 (02) :69-80
[4]  
[Anonymous], 1993, VDI WARMEATLAS VDI H
[5]   EXPERIMENTAL INVESTIGATION OF THE AUGMENTATION OF FORCED-CONVECTION HEAT-TRANSFER IN A CIRCULAR TUBE USING SPIRAL SPRING INSERTS [J].
CHIOU, JP .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1987, 109 (02) :300-307
[6]   PRESSURE-GRADIENTS DUE TO FRICTION DURING FLOW OF EVAPORATING 2-PHASE MIXTURES IN SMOOTH TUBES AND CHANNELS [J].
CHISHOLM, D .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1973, 16 (02) :347-358
[7]  
Friedel L., 1979, European Two Phase Flow Group Meeting Paper, V18, P485
[8]  
GRONNERUD R, 1972, B HNST
[9]  
LOCHART RW, 1979, CHEM ENG PROGR, V45, P39
[10]   A SIMPLE FRICTION PRESSURE-DROP CORRELATION FOR 2-PHASE FLOW IN PIPES [J].
MULLERSTEINHAGEN, H ;
HECK, K .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1986, 20 (06) :297-308