The influence of citrate, EDTA, and heparin anticoagulants to human plasma LC-MS lipidomic profiling

被引:56
作者
Gonzalez-Covarrubias, Vanessa [1 ,2 ]
Dane, Adrie [1 ,2 ]
Hankemeier, Thomas [1 ,2 ]
Vreeken, Rob J. [1 ,2 ]
机构
[1] Netherlands Metab Ctr, Leiden, Netherlands
[2] Leiden Univ, LACDR, Leiden, Netherlands
关键词
Anticoagulant; EDTA; Citrate; Heparin; Lipidomics; LC-MS; TANDEM MASS-SPECTROMETRY; BLOOD; VALIDATION; COLLECTION; EXTRACTION; INVITRO; ASSAYS;
D O I
10.1007/s11306-012-0450-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Lipid profiling of human plasma by liquid chromatography-electrospray ionization coupled to mass spectrometry (LC-ESI-MS) is being used to identify biomarkers of health, disease, and treatment efficacy. However, there is no consensus on the choice of anticoagulant to perform and compare lipidomic measurements. This study assessed the effect of the anticoagulants citrate, EDTA, and heparin, on eight synthetic and 80 plasma lipids, and compared lipidomic data among anticoagulants. Lipid extraction was affected distinctively by the anticoagulant of choice likely due to the different physico-chemical properties among anticoagulants. Peak areas of seventy endogenous lipids showed significant differences between citrate-heparin and EDTA-heparin comparisons similar to those observed for synthetic lipids. Only ten endogenous lipid species showed comparable peak areas among the three anticoagulants. Correction by a structurally related internal standard only partly eliminated differences among anticoagulants (ANOVA, P value < 0.001). However, comparisons among anticoagulants were possible for most endogenous lipids after correction of peak areas by the sum of areas of its lipid class. Our observations indicate that the choice of anticoagulant distinctively impact the peak response of most lipid species by LC-ESI-MS. Lipidomic data from plasma obtained with different anticoagulants should address differences in matrix effects and extraction procedures since ion strength, plasma pH, and different physicochemical properties among anticoagulants influence lipid extraction and LC-ESI-MS analysis.
引用
收藏
页码:337 / 348
页数:12
相关论文
共 24 条
[1]   The influence of EDTA and citrate anticoagulant addition to human plasma on information recovery from NMR-based metabolic profiling studies [J].
Barton, Richard H. ;
Waterman, Daniel ;
Bonner, Frank W. ;
Holmes, Elaine ;
Clarke, Robert ;
Nicholson, Jeremy K. ;
Lindon, John C. .
MOLECULAR BIOSYSTEMS, 2010, 6 (01) :215-224
[2]  
Bergheanu SC, 2008, CURR MED RES OPIN, V24, P2477, DOI [10.1185/03007990802321709, 10.1185/03007990802321709 ]
[3]  
BLIGH EG, 1959, CAN J BIOCHEM PHYS, V37, P911
[4]   IBUPROFEN PICONOL HYDROLYSIS INVITRO IN PLASMA, WHOLE-BLOOD, AND SERUM USING DIFFERENT ANTICOAGULANTS [J].
CHRISTENSEN, JM ;
STALKER, D .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1991, 80 (01) :29-31
[5]   Effect of anticoagulants and storage temperatures on stability of plasma and serum hormones [J].
Evans, MJ ;
Livesey, JH ;
Ellis, MJ ;
Yandle, TG .
CLINICAL BIOCHEMISTRY, 2001, 34 (02) :107-112
[6]   Top-Down Lipidomics Reveals Ether Lipid Deficiency in Blood Plasma of Hypertensive Patients [J].
Graessler, Juergen ;
Schwudke, Dominik ;
Schwarz, Peter E. H. ;
Herzog, Ronny ;
Shevchenko, Andrej ;
Bornstein, Stefan R. .
PLOS ONE, 2009, 4 (07)
[7]   Lipidomics at the interface of Structure and Function in Systems Biology [J].
Gross, Richard W. ;
Han, Xianlin .
CHEMISTRY & BIOLOGY, 2011, 18 (03) :284-291
[8]   RPLC-Ion-Trap-FTMS Method for Lipid Profiling of Plasma: Method Validation and Application to p53 Mutant Mouse Model [J].
Hu, Chunxiu ;
van Dommelen, Judith ;
van der Heijden, Rob ;
Spijksma, Gerwin ;
Reijmers, Theo H. ;
Wang, Mei ;
Slee, Elizabeth ;
Lu, Xin ;
Xu, Guowang ;
van der Greef, Jan ;
Hankemeier, Thomas .
JOURNAL OF PROTEOME RESEARCH, 2008, 7 (11) :4982-4991
[9]  
Jessome LL, 2006, LC GC N AM, V24, P498
[10]  
JOHNSTONE IB, 1993, CAN VET J, V34, P627